Source author record

Marcelo Guarini

Marcelo Guarini appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

Optimal CCD readout by digital correlated double sampling

Digital correlated double sampling (DCDS), a readout technique for charge-coupled devices (CCD), is gaining popularity in astronomical applications. By using an oversampling ADC and a digital filter, a DCDS system can achieve a better performance than traditional analogue readout techniques at the expense of a more complex system analysis. Several attempts to analyse and optimize a DCDS system have been reported, but most of the work presented in the literature has been experimental. Some approximate analytical tools have been presented for independent parameters of the system, but the overall performance and trade-offs have not been yet modelled. Furthermore, there is disagreement among experimental results that cannot be explained by the analytical tools available. In this work, a theoretical analysis of a generic DCDS readout system is presented, including key aspects such as the signal conditioning stage, the ADC resolution, the sampling frequency and the digital filter implementation. By using a time-domain noise model, the effect of the digital filter is properly modelled as a discrete-time process, thus avoiding the imprecision of continuous-time approximations that have been used so far. As a result, an accurate, closed-form expression for the signal-to-noise ratio at the output of the readout system is reached. This expression can be easily optimized in order to meet a set of specifications for a given CCD, thus providing a systematic design methodology for an optimal readout system. Simulated results are presented to validate the theory, obtained with both time- and frequency-domain noise generation models for completeness.

preprint2015arXiv

Theoretical Framework and Simulation Results for Implementing Weighted Multiple Sampling in Scientific CCDs

The Digital Correlated Double Sampling (DCDS) is a technique based on multiple analog-to-digital conversions of every pixel when reading a CCD out. This technique allows to remove analog integrators, simplifying the readout electronics circuitry. In this work, a theoretical framework that computes the optimal weighted coefficients of the pixels samples, which minimize the readout noise measured at the CCD output is presented. By using a noise model for the CCD output amplifier where white and flicker noise are treated separately, the mathematical tool presented allows for the computation of the optimal samples coefficients in a deterministic fashion. By modifying the noise profile, our simulation results get in agreement and thus explain results that were in mutual disagreement up until now.