Source author record

Mahmoud Abbas

Mahmoud Abbas appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2020arXiv

Plexus Convolutional Neural Network (PlexusNet): A novel neural network architecture for histologic image analysis

Different convolutional neural network (CNN) models have been tested for their application in histological image analyses. However, these models are prone to overfitting due to their large parameter capacity, requiring more data or valuable computational resources for model training. Given these limitations, we introduced a novel architecture (termed PlexusNet). We utilized 310 Hematoxylin and Eosin stained (H&E) annotated histological images of prostate cancer cases from TCGA-PRAD and Stanford University and 398 H&E whole slides images from the Camelyon 2016 challenge. PlexusNet-architecture -derived models were compared to models derived from several existing "state of the art" architectures. We measured discrimination accuracy, calibration, and clinical utility. An ablation study was conducted to study the effect of each component of PlexusNet on model performance. A well-fitted PlexusNet-based model delivered comparable classification performance (AUC: 0.963) in distinguishing prostate cancer from healthy tissues, although it was at least 23 times smaller, had a better model calibration and clinical utility than the comparison models. A separate smaller PlexusNet model accurately detected slides with breast cancer metastases (AUC: 0.978); it helped reduce the slide number to examine by 43.8% without consequences, although its parameter capacity was 200 times smaller than ResNet18. We found that the partitioning of the development set influences the model calibration for all models. However, with PlexusNet architecture, we could achieve comparable well-calibrated models trained on different partitions. In conclusion, PlexusNet represents a novel model architecture for histological image analysis that achieves classification performance comparable to other models while providing orders-of-magnitude parameter reduction.