Researcher profile

Madhur Parashar

Madhur Parashar contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Sub-second Temporal Magnetic Field Microscopy Using Quantum Defects in Diamond

Wide field-of-view magnetic field microscopy has been realised by probing shifts in optically detected magnetic resonance (ODMR) spectrum of Nitrogen Vacancy (NV) defect centers in diamond. However, these widefield diamond NV magnetometers require few to several minutes of acquisition to get a single magnetic field image, rendering the technique temporally static in it's current form. This limitation prevents application of diamond NV magnetometers to novel imaging of dynamically varying microscale magnetic field processes. Here, we show that the magnetic field imaging frame rate can be significantly enhanced by performing lock-in detection of NV photo-luminescence (PL), simultaneously over multiple pixels of a lock-in camera. A detailed protocol for synchronization of frequency modulated PL of NV centers with fast camera frame demodulation, at few kilohertz frequencies, has been experimentally demonstrated. This experimental technique allows magnetic field imaging of sub-second varying microscale currents in planar microcoils with imaging frame rates in the range of 50 to 200 frames per second (fps). Our work demonstrates that widefield per-pixel lock-in detection of frequency modulated NV ODMR enables dynamic magnetic field microscopy.

preprint2020arXiv

Axon Hillock Currents Allow Single-Neuron-Resolution 3-Dimensional Functional Neural Imaging Using Diamond Quantum Defect-Based Vector Magnetometry

Magnetic field sensing, with its recent advances, is emerging as a viable alternative to measure functional activity of single neurons in the brain by sensing action potential associated magnetic fields (APMFs). Measurement of APMFs of large axons of worms have been possible due to their size. In the mammalian brain, axon sizes, their numbers and routes, restricts using such functional imaging methods. With segmented model of mammalian pyramidal neurons, we show that the APMF of intra-axonal currents in the axon hillock are two orders of magnitude larger than other neuronal locations. Expected 2-dimensional vector magnetic field maps of naturalistic spiking activity of a volume of neurons via widefield diamond-nitrogen-vacancy-center-magnetometry (DNVM) were simulated. A dictionary based matching pursuit type algorithm applied to the data using the axon-hillock's APMF signature allowed spatiotemporal reconstruction of APs in the volume of brain tissue at single cell resolution. Enhancement of APMF signals coupled with NVMM advances thus can potentially replace current functional brain mapping techniques.