Researcher profile

M. Turner

M. Turner contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
9works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

In-situ study of mineral liberation at the onset of fragmentation of a copper ore using X-ray micro-computed tomography

A better understanding of the relation between ore fragmentation and ore texture is a key to the energy efficient extraction of targeted minerals from low grade ore deposits. In this study, X-ray micro-computed tomography is employed to study mineral liberation during the tensile failure and onset of fragmentation of a copper ore. We present the results of experiments based on a high-pressure instrument enabling micro-mechanical studies to be carried out in-situ (inside a micro-CT scanner). This experimental platform enables mapping in 3D of the evolution of a sample of copper ore during an in-situ fragmentation test. The fragmentation occurs quasi-statically via tensile-activated nucleation and growth of multiple cracks producing a complex fracture network. Coupling breakage with microstructural information, we determine quantitatively the impact of ore textural features on fracture patterns and mineral liberation. This information can be compared to the ore mechanical behaviour, in particular to measurements of the deformation energy, the strain deformation field or the stress relaxation response. The copper liberation, fragment size distribution and breakage patterns are statistically characterised and related to two dominant comminution mechanisms which are clearly identified in the sequence of tomographic images. Our results show that in-situ micro-CT experiments could inform new studies of ore fragmentation at the laboratory scale and may offer new avenues to address current challenges in the design of efficient comminution processes.

preprint2022arXiv

Mapping charge capture and acceleration in a plasma wakefield of a proton bunch using variable emittance electron beam injection

In the Phase 2 of the AWAKE first experimental run (from May to November 2018), an electron beam was used to probe and test proton-driven wakefield acceleration in a rubidium plasma column. In this work, we analyze the overall charge capture and shot-to-shot reproducibility of the proton-driven plasma wakefield accelerator with various electron bunch injection parameters. The witness electron bunches were produced using an RF-gun equipped with a Cs2Te photocathode illuminated by a tailorable ultrafast deep ultraviolet (UV) laser pulse. The construction of the UV beam optical system enabled appropriate transverse beam shaping and control of its pulse duration, size, and position on the photocathode, as well as time delay with respect to the ionizing laser pulse that seeds the plasma wakefields in the proton bunches. Variable photocathode illumination provided the required flexibility to produce electron bunches with variable charge, emittance, and injection trajectory into the plasma column. We demonstrate charge capture rates exceeding 15% (40 pC of GeV accelerated charge for a 385 pC injected electron bunch) under optimized electron injection conditions.

preprint2021arXiv

Analysis of Proton Bunch Parameters in the AWAKE Experiment

A precise characterization of the incoming proton bunch parameters is required to accurately simulate the self-modulation process in the Advanced Wakefield Experiment (AWAKE). This paper presents an analysis of the parameters of the incoming proton bunches used in the later stages of the AWAKE Run 1 data-taking period. The transverse structure of the bunch is observed at multiple positions along the beamline using scintillating or optical transition radiation screens. The parameters of a model that describes the bunch transverse dimensions and divergence are fitted to represent the observed data using Bayesian inference. The analysis is tested on simulated data and then applied to the experimental data.

preprint2021arXiv

Radial Density Profile and Stability of Capillary Discharge Plasma Waveguides of Lengths up to 40 Centimeters

We measured the parameter reproducibility and radial electron density profile of capillary discharge waveguides with diameters of 650 um to 2 mm and lengths of 9 to 40 cm. To our knowledge, 40 cm is the longest discharge capillary plasma waveguide to date. This length is important for >= 10 GeV electron energy gain in a single laser driven plasma wakefield acceleration (LPA) stage. Evaluation of waveguide parameter variations showed that their focusing strength was stable and reproducible to <0.2% and their average on-axis plasma electron density to <1%. These variations explain only a small fraction of LPA electron bunch variations observed in experiments to date. Measurements of laser pulse centroid oscillations revealed that the radial channel profile rises faster than parabolic and are in excellent agreement with magneto-hydro-dynamic simulation results. We show that the effects of non-parabolic contributions on Gaussian pulse propagation were negligible when the pulse was approximately matched to the channel. However, they affected pulse propagation for a non-matched configuration in which the waveguide was used as a plasma telescope to change the focused laser pulse spot size.

preprint2020arXiv

Electron beam characterization with beam loss monitors in AWAKE

We present a method to measure transverse size and position of an electron or proton beam, close to the injection point in plasma wakefields, where other diagnostics are not available. We show that transverse size measurements are in agreement with values expected from the beam optics with a $< 10\%$ uncertainty. We confirm the deflection of the low-energy 18 MeV electron beam trajectory by the Earth&#39;s magnetic field. This measurement can be used to correct for this effect and set proper electron bunch injection parameters. The advanced wakefield experiment at CERN (AWAKE) relies on these measurements for optimizing electron injection.

preprint2020arXiv

Experimental Study of Wakefields Driven by a Self-Modulating Proton Bunch in Plasma

We study experimentally the longitudinal and transverse wakefields driven by a highly relativistic proton bunch during self-modulation in plasma. We show that the wakefields&#39; growth and amplitude increase with increasing seed amplitude as well as with the proton bunch charge in the plasma. We study transverse wakefields using the maximum radius of the proton bunch distribution measured on a screen downstream from the plasma. We study longitudinal wakefields by externally injecting electrons and measuring their final energy. Measurements agree with trends predicted by theory and numerical simulations and validate our understanding of the development of self-modulation. Experiments were performed in the context of the Advanced Wakefield Experiment (AWAKE).

preprint2020arXiv

Proton beam defocusing in AWAKE: comparison of simulations and measurements

In 2017, AWAKE demonstrated the seeded self-modulation (SSM) of a 400 GeV proton beam from the Super Proton Synchrotron (SPS) at CERN. The angular distribution of the protons deflected due to SSM is a quantitative measure of the process, which agrees with simulations by the two-dimensional (axisymmetric) particle-in-cell code LCODE. Agreement is achieved for beam populations between $10^{11}$ and $3 \times 10^{11}$ particles, various plasma density gradients ($-20 ÷20\%$) and two plasma densities ($2\times 10^{14} \text{cm}^{-3}$ and $7 \times 10^{14} \text{cm}^{-3}$). The agreement is reached only in the case of a wide enough simulation box (at least five plasma wavelengths).

preprint2017arXiv

AWAKE readiness for the study of the seeded self-modulation of a 400\,GeV proton bunch

AWAKE is a proton-driven plasma wakefield acceleration experiment. % We show that the experimental setup briefly described here is ready for systematic study of the seeded self-modulation of the 400\,GeV proton bunch in the 10\,m-long rubidium plasma with density adjustable from 1 to 10$\times10^{14}$\,cm$^{-3}$. % We show that the short laser pulse used for ionization of the rubidium vapor propagates all the way along the column, suggesting full ionization of the vapor. % We show that ionization occurs along the proton bunch, at the laser time and that the plasma that follows affects the proton bunch. %