Source author record

M. T. Ceballos

M. T. Ceballos appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2020arXiv

The XMM-Newton serendipitous survey IX. The fourth XMM-Newton serendipitous source catalogue

Sky surveys produce enormous quantities of data on extensive regions of the sky. The easiest way to access this information is through catalogues of standardised data products. {\em XMM-Newton} has been surveying the sky in the X-ray, ultra-violet, and optical bands for 20 years. The {\em XMM-Newton} Survey Science Centre has been producing standardised data products and catalogues to facilitate access to the serendipitous X-ray sky. Using improved calibration and enhanced software, we re-reduced all of the 14041 {\em XMM-Newton} X-ray observations, of which 11204 observations contained data with at least one detection and with these we created a new, high quality version of the {\em XMM-Newton} serendipitous source catalogue, 4XMM-DR9. 4XMM-DR9 contains 810795 detections down to a detection significance of 3 $σ$, of which 550124 are unique sources, which cover 1152 degrees$^{2}$ (2.85\%) of the sky. Filtering 4XMM-DR9 to retain only the cleanest sources with at least a 5 $σ$ detection significance leaves 433612 detections. Of these detections, 99.6\% have no pileup. Furthermore, 336 columns of information on each detection are provided, along with images. The quality of the source detection is shown to have improved significantly with respect to previous versions of the catalogues. Spectra and lightcurves are also made available for more than 288000 of the brightest sources (36\% of all detections).

preprint2020arXiv

The XMM-Newton serendipitous survey. X: The second source catalogue from overlapping XMM-Newton observations and its long-term variable content

The XMM-Newton Survey Science Centre Consortium (SSC) develops software in close collaboration with the Science Operations Centre to perform a pipeline analysis of all XMM-Newton observations. In celebration of the 20th launch anniversary, the SSC has compiled the 4th generation of serendipitous source catalogues, 4XMM. The catalogue described here, 4XMM-DR9s, explores sky areas that were observed more than once by XMM-Newton. It was constructed from simultaneous source detection on the overlapping observations, which were bundled in groups ("stacks"). Stacking leads to a higher sensitivity, resulting in newly discovered sources and better constrained source parameters, and unveils long-term brightness variations. As a novel feature, positional rectification was applied beforehand. Observations with all filters and suitable camera settings were included. Exposures with a high background were discarded, which was determined through a statistical analysis of all exposures in each instrument configuration. The X-ray background maps used in source detection were modelled via adaptive smoothing with newly determined parameters. Source fluxes were derived for all contributing observations, irrespective of whether the source would be detectable in an individual observation. From 1,329 stacks with 6,604 contributing observations over repeatedly covered 300 square degrees in the sky, 4XMM-DR9s lists 288,191 sources. 218,283 of them were observed several times. Most stacks are composed of two observations, the largest one comprises 352. The number of observations of a source ranges from 1 to 40. Auxiliary products like X-ray images, long-term light curves, and optical finding charts are published as well. 4XMM-DR9s is considered a prime resource to explore long-term variability of X-ray sources discovered by XMM-Newton. Regular incremental releases including new public observations are planned.

preprint2016arXiv

The XMM-Newton serendipitous survey. VII. The third XMM-Newton serendipitous source catalogue

Thanks to the large collecting area (3 x ~1500 cm$^2$ at 1.5 keV) and wide field of view (30' across in full field mode) of the X-ray cameras on board the European Space Agency X-ray observatory XMM-Newton, each individual pointing can result in the detection of hundreds of X-ray sources, most of which are newly discovered. Recently, many improvements in the XMM-Newton data reduction algorithms have been made. These include enhanced source characterisation and reduced spurious source detections, refined astrometric precision, greater net sensitivity and the extraction of spectra and time series for fainter sources, with better signal-to-noise. Further, almost 50\% more observations are in the public domain compared to 2XMMi-DR3, allowing the XMM-Newton Survey Science Centre (XMM-SSC) to produce a much larger and better quality X-ray source catalogue. The XMM-SSC has developed a pipeline to reduce the XMM-Newton data automatically and using improved calibration a new catalogue version has been produced from XMM-Newton data made public by 2013 Dec. 31 (13 years of data). Manual screening ensures the highest data quality. This catalogue is known as 3XMM. In the latest release, 3XMM-DR5, there are 565962 X-ray detections comprising 396910 unique X-ray sources. For the 133000 brightest sources, spectra and lightcurves are provided. For all detections, the positions on the sky, a measure of the quality of the detection, and an evaluation of the X-ray variability is provided, along with the fluxes and count rates in 7 X-ray energy bands, the total 0.2-12 keV band counts, and four hardness ratios. To identify the detections, a cross correlation with 228 catalogues is also provided for each X-ray detection. 3XMM-DR5 is the largest X-ray source catalogue ever produced. Thanks to the large array of data products, it is an excellent resource in which to find new and extreme objects.

preprint2013arXiv

The Hot and Energetic Universe: Understanding the build-up of supermassive black holes and galaxies at the heyday of the Universe

Observations in the last decade have provided strong evidence that the growth of supermassive black holes at the centres of galaxies is among the most influential processes in galaxy evolution. Open questions that relate to our current understanding of black hole growth and its relation to the build-up of galaxies at redshifts z=1-4, when most black holes and stars we see in present-day galaxies were put in place, include: what is the nature of AGN feedback and whether it plays a significant role in the evolution of galaxies? what is the dominant population of accreting AGN at that critical epoch? is it dominated by obscured objects as required by many current observations and models? The Athena+ mission concept will provide the technological leap required for a breakthrough in our understanding of AGN and galaxy evolution at the heyday of the Universe. The high throughput of Athena+ will allow the systematic study of the incidence, nature and energetics of AGN feedback processes to z~4 via the identification and measurement of blue-shifted X-ray absorption lines. The excellent survey and spectral capabilities of the Athena+ Wide Field Imager will complete the census of black hole growth by yielding samples of up to 100 times larger than is currently possible of the most heavily obscured, including Compton thick, AGN to redshifts z~4. The demographics of this population relative to their hosts is fundamental for understanding how major black hole growth events relate to the build-up of galaxies.

preprint2013arXiv

The XMM-Newton SSC survey of the Galactic Plane

Many different classes of X-ray sources contribute to the Galactic landscape at high energies. Although the nature of the most luminous X-ray emitters is now fairly well understood, the population of low-to-medium X-ray luminosity (Lx = 10^27-10^34 erg/s) sources remains much less studied, our knowledge being mostly based on the observation of local members. The advent of wide field and high sensitivity X-ray telescopes such as XMM-Newton now offers the opportunity to observe this low-to-medium Lx population at large distances. We report on the results of a Galactic plane survey conducted by the XMM-Newton Survey Science Centre (SSC). Beyond its astrophysical goals, this survey aims at gathering a representative sample of identified X-ray sources at low latitude that can be used later on to statistically identify the rest of the serendipitous sources discovered in the Milky Way. The survey is based on 26 XMM-Newton observations, obtained at |b| < 20 deg, distributed over a large range in Galactic longitudes and covering a summed area of 4 deg2. The flux limit of our survey is 2 x 10-15 erg/cm^2/s in the soft (0.5 - 2 keV) band and 1 x 10^-14 erg/cm^2/s in the hard (2 - 12 keV) band. We detect a total of 1319 individual X-ray sources. Using optical follow-up observations supplemented by cross-correlation with a large range of multi-wavelength archival catalogues we identify 316 X-ray sources. This constitutes the largest group of spectroscopically identified low latitude X-ray sources at this flux level. The majority of the identified X-ray sources are active coronae with spectral types in the range A - M at maximum distances of ~ 1 kpc. The number of identified active stars increases towards late spectral types, reaching a maximum at K. (abridged)

preprint2013arXiv

The XMM-Newton Wide Angle Survey (XWAS)

This programme is aimed at obtaining one of the largest X-ray selected samples of identified active galactic nuclei to date in order to characterise such a population at intermediate fluxes, where most of the Universe's accretion power originates. We present the XMM-Newton Wide Angle Survey (XWAS), a new catalogue of almost a thousand X-ray sources spectroscopically identified through optical observations. A sample of X-ray sources detected in 68 XMM-Newton pointed observations was selected for optical multi-fibre spectroscopy. Optical counterparts and corresponding photometry of the X-ray sources were obtained from the SuperCOSMOS Sky Survey. Candidates for spectroscopy were initially selected with magnitudes down to R~21, with preference for X-ray sources having a flux F(0.5-4.5 keV) >10^-14 erg s^-1 cm^-2. Optical spectroscopic observations performed at the Anglo Australian Telescope Two Degree Field were analysed, and the derived spectra were classified based on optical emission lines. We have identified through optical spectroscopy 940 X-ray sources over ~11.8 deg^2 of the sky. Source populations in our sample can be summarised as 65% broad line active galactic nuclei (BLAGN), 16% narrow emission line galaxies (NELGs), 6% absorption line galaxies (ALGs) and 13% stars. An active nucleus is likely to be present also in the large majority of the X-ray sources spectroscopically classified as NELGs or ALGs. Sources lie in high-galactic latitude (|b| > 20 deg) XMM-Newton fields mainly in the southern hemisphere. Due to the large parameter space in redshift (0 < z < 4.25) and flux (10^-15 < F(0.5-4.5 keV) < 10^-12 erg s^-1 cm^-2) covered by the XWAS this work provides an excellent resource to further study subsamples and particular cases. The overall properties of the extragalactic objects are presented in this paper.

preprint2009arXiv

The XMM-Newton Wide Angle Survey (XWAS): the X-ray spectrum of type-1 AGN

We discuss the broad band X-ray properties of one of the largest samples of X-ray selected type-1 AGN to date (487 objects in total), drawn from the XMM-Newton Wide Angle Survey. The objects cover 2-10 keV luminosities from ~10^{42}-10^{45} erg s^{-1} and are detected up to redshift ~4. We constrain the overall properties of the broad band continuum, soft excess and X-ray absorption, along with their dependence on the X-ray luminosity and redshift and we discuss the implications for models of AGN emission. We constrained the mean spectral index of the broad band X-ray continuum to <Gamma>=1.96+-0.02 with intrinsic dispersion sigma=0.27_{-0.02}^{+0.01}. The continuum becomes harder at faint fluxes and at higher redshifts and luminosities. The dependence of Gamma with flux is likely due to undetected absorption rather than to spectral variation. We found a strong dependence of the detection efficiency of objects on the spectral shape which can have a strong impact on the measured mean continuum shapes of sources at different redshifts and luminosities. We detected excess absorption in ~3% of our objects, with column densities ~a few x10^{22} cm^{-2}. The apparent mismatch between the optical classification and X-ray properties of these objects is a challenge for the standard AGN unification model. We found that the fraction of objects with detected soft excess is ~36%. Using a thermal model, we constrained the soft excess mean temperature and intrinsic dispersion to <kT>~100 eV and sigma~34 eV. The origin of the soft excess as thermal emission from the accretion disk or Compton scattered disk emission is ruled out on the basis of the temperatures detected and the lack of correlation of the measured temperature with the X-ray luminosity (abridged).

preprint2004arXiv

Simultaneous X-Ray and optical spectroscopy of the Seyfert galaxy Mrk 993

We present the results of simultaneous XMM-Newton X-ray and 3.5m/CAHA optical spectroscopic observations of the Seyfert galaxy Mrk 993. This galaxy exhibited in the past significant variations of its broad emission lines which classified it as Sy1, Sy1.5 and Sy1.9 in different epochs. In order to test the X-ray/optical consistency of the unified AGN model we have compared the amount of photoelectric X-ray absorption with the Balmer decrement of broad emission line components. The optical data show that during our observations Mrk 993 was in a Sy1.8 state with a Balmer decrement of 9. The X-ray absorbing gas amounts only to 7E20 cmE-02, most likely due to the host galaxy. For a normal gas to dust ratio in the absorbing material (expected to arise in the molecular torus) both quantities are clearly discrepant with an intrinsic Balmer decrement of 3.4. We therefore conclude that the Balmer ratio is intrinsic rather than produced by obscuration and therefore that in this object the optical broad line emission properties are dictated by the physics of the broad line region rather than orientation/obscuration effects.

preprint2002arXiv

The XMM-Newton Survey Science Centre Medium Sensitivity Survey

We present preliminary results on the XMM-Newton Survey Science Centre medium sensitivity survey (XMS), with 0.5-4.5 keV flux limit 2 10^{-14} erg/cm2/s. At present, 19 fields have been examined with a total of 239 X-ray sources. Identifications for about 2/3 of these reveal that type 1 AGN dominate, but type 2 AGN, absorption-line galaxies and clusters as well as stars are also present. We also discuss on a few X-ray selected Broad-Absorption-Line QSOs found in this survey.

preprint1994arXiv

On the Influence of X-Ray Galaxy Clusters in the Fluctuations of the Cosmic Microwave Background

The negative evolution found in X--ray clusters of galaxies limits the amount of available hot gas for the inverse Compton scattering of the Cosmic Microwave Background (the Sunyaev--Zel'dovich effect). Using a parametrisation of the X-ray luminosity function and its evolution in terms of a coalescence model (as presented in the analysis of a flux limited X-ray cluster sample by Edge et al. 1990), as well as a simple virialised structure for the clusters (which requires a gas to total mass fraction $\approxgt 0.1$ in order to reproduce observed properties of nearby clusters) we show that the Compton distortion $y$ parameter is about two orders of magnitude below the current FIRAS upper limits. Concerning the anisotropies imprinted on arcmin scales they are dominated by the hottest undetected objects. We show that they are negligible (${ΔT\over T}\approxlt 10^{-7}$) at wavelengths $λ\approxgt 1$~mm. At shorter wavelengths they become more important (${ΔT\over T}\sim 10^{-6}$ at $λ\sim 0.3$~mm), but in fact most clusters will produce an isolated and detectable feature in sky maps. After removal of these signals, the fluctuations imprinted by the remaining clusters on the residual radiation are still much smaller. The conclusion is that X-ray clusters can be ignored as sources of Cosmic Microwave Background fluctuations.