Source author record

M. Ronquest

M. Ronquest appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2016arXiv

Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1

The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV. In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be $<1.4\times 10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil acceptance of at least 90%, with 4% systematic uncertainty on the absolute energy scale. The discrimination measurement on surface was limited by nuclear recoils induced by cosmic-ray generated neutrons. This was improved by moving the detector to the SNOLAB underground laboratory, where the reduced background rate allowed the same measurement with only a double-coincidence tag. The combined data set contains $1.23\times10^8$ events. One of those, in the underground data set, is in the nuclear-recoil region of interest. Taking into account the expected background of 0.48 events coming from random pileup, the resulting upper limit on the electronic recoil contamination is $<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil acceptance of at least 90%, with 6% systematic uncertainty on the absolute energy scale. We developed a general mathematical framework to describe PSD parameter distributions and used it to build an analytical model of the distributions observed in DEAP-1. Using this model, we project a misidentification fraction of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for a detector with 8 PE/keVee light yield. This reduction enables a search for spin-independent scattering of WIMPs from 1000 kg of liquid argon with a WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming negligible contribution from nuclear recoil backgrounds.

preprint2014arXiv

Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector

The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them. The $^{222}$Rn decay rate in the liquid argon was measured to be between 16 and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry.

preprint2011arXiv

Search for the Rare Decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-

The KTeV E799 experiment has conducted a search for the rare decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-, where the X0 is a possible new neutral boson that was reported by the HyperCP experiment with a mass of (214.3 pm 0.5) MeV/c^{2}. We find no evidence for either decay. We obtain upper limits of Br(KL->pi0pi0X0->pi0pi0mu+mu-) < 1.0 x 10^{-10} and Br(KL->pi0pi0mu+mu-) < 9.2 x 10^{-11} at the 90% confidence level. This result rules out the pseudoscalar X0 as an explanation of the HyperCP result under the scenario that the \bar{d}sX0 coupling is completely real.

preprint2010arXiv

Precise Measurements of Direct CP Violation, CPT Symmetry, and Other Parameters in the Neutral Kaon System

We present precise tests of CP and CPT symmetry based on the full dataset of K to pipi decays collected by the KTeV experiment at Fermi National Accelerator Laboratory during 1996, 1997, and 1999. This dataset contains 16 million K to 2pi0 and 69 million K to pi+pi- decays. We measure the direct CP violation parameter Re(epsilon'/epsilon) = (19.2 pm 2.1)x10-4. We find the KL-KS mass difference Deltam = (5270 pm 12)x10^6 hbar/s and the KS lifetime tauS = (89.62 pm 0.05)x10-12 s. We also measure several parameters that test CPT invariance. We find the difference between the phase of the indirect CP violation parameter, epsilon, and the superweak phase, phi_epsilon - phi_SW = (0.40 pm 0.56) degrees. We measure the difference of the relative phases between the CP violating and CP conserving decay amplitudes for K to pi+pi- (phi+-) and for K to 2pi0 (phi00), Delta phi = (0.30 pm 0.35) degrees. From these phase measurements, we place a limit on the mass difference between K0 and K0bar, DeltaM < 4.8 x 10-19 GeV/c^2 at 95% C.L. These results are consistent with those of other experiments, our own earlier measurements, and CPT symmetry.

preprint2009arXiv

Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter

Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.

preprint2008arXiv

Final Results from the KTeV Experiment on the Decay KL -> pi0 gamma gamma

We report on a new measurement of the branching ratio B(KL->pi0 gamma gamma)using the KTeV detector. We reconstruct 1982 events with an estimated background of 608, that results in B(KL -> pi0 gamma gamma) = (1.29 +/- 0.03(stat) +/- 0.05(syst)) x 10**-6. We also measure the parameter, aV, which characterizes the strength of vector meson exchange terms in this decay. We find aV = -0.31 +/- 0.05(stat) +/- 0.07(syst). These results utilize the full KTeV data set collected from 1997 to 2000 and supersede earlier KTeV measurements of the branching ratio and aV.

preprint2004arXiv

Measurements of the Branching Fractions and Decay Distributions for KL->πμνγand KL->πeνγ

We present measurements of R_Kl3rad = Gamma(KL->π\ellνγ; Egcm > 10 MeV)/Gamma(KL->π\ellν), where ell = mu or e, and Egcm is the photon energy in the kaon rest frame. These measurements are based on KL decays collected in 1997 by the KTeV (E832) experiment at Fermilab. With samples of 1385 KL->πμνγand 14221 KL->π\eνγcandidates, we find R_Km3rad = (0.530 +- 0.019)% and R_Ke3rad = (4.942 +- 0.062)%. We also examine distributions of photon energy and lepton-photon angle.