Source author record

M. Kubasik

M. Kubasik appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2009arXiv

Trapping Ultracold Atoms in a Time-Averaged Adiabatic Potential

We report the first experimental realization of ultracold atoms confined in a time-averaged, adiabatic potential (TAAP). This novel trapping technique involves using a slowly oscillating ($\sim$ kHz) bias field to time-average the instantaneous potential given by dressing a bare magnetic potential with a high frequency ($\sim$ MHz) magnetic field. The resultant potentials provide a convenient route to a variety of trapping geometries with tunable parameters. We demonstrate the TAAP trap in a standard time-averaged orbiting potential trap with additional Helmholtz coils for the introduction of the radio frequency dressing field. We have evaporatively cooled 5 $\times 10^4$ atoms of $^{87}$Rb to quantum degeneracy and observed condensate lifetimes of over \unit[3]{s}.-

preprint2009arXiv

Ultra--low noise differential AC-coupled photodetector for sensitive pulse detection applications

We report on the performance of ultra low noise differential photodetectors especially designed for probing of atomic ensembles with weak light pulses. The working principle of the detectors is described together with the analysis procedures employed to extract the photon shot noise of light pulses with $\sim1 μ$s duration. As opposed to frequency response peaked detectors, our approach allows for broadband quantum noise measurements. The equivalent noise charge (ENC) for two different hardware approaches is evaluated to 280 and 340 electrons per pulse, respectively which corresponds to a dark noise equivalent photon number of $n_\mathrm{3dB}=0.8\cdot 10^5$ and $n_\mathrm{3dB}=1.2\cdot 10^5$ in the two approaches. Finally, we discuss the possibility of removing classical correlations in the output signal caused by detector imperfection by using double--correlated sampling methods.