Source author record

M. De Gerone

M. De Gerone appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

17works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

17 published item(s)

preprint2024arXiv

A search for $μ^+\to e^+γ$ with the first dataset of the MEG II experiment

The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $μ^+\to e^+γ$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($μ^+\to e^+γ$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($μ^+\to e^+γ$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.

preprint2024arXiv

Operation and performance of MEG II detector

The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

preprint2021arXiv

Progress in the development of TES microcalorimeter detectors suitable for neutrino mass measurement

The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiNx membrane with gold absorbers. Considering the large number of pixels and an event rate of about 300 Hz/pixel, a large multiplexing factor and a large bandwidth are needed. To fulfill this requirement, HOLMES will exploit recent advances in microwave multiplexing. In this contribution, we present the status of the activities in development, the performances of the developed microwave-multiplexed readout system, and the results obtained with the detectors specifically designed for HOLMES in terms of noise, time, and energy resolutions

preprint2016arXiv

Measurement of the radiative decay of polarized muons in the MEG experiment

We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV and E_γ > 40 MeV, consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for $μ^+ \to e^+γ$ process.

preprint2016arXiv

Muon polarization in the MEG experiment: predictions and measurements

The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stopping target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at the production is predicted to be $P_μ = -1$ by the Standard Model (SM) with massless neutrinos. We estimated our residual muon polarization to be $P_μ = -0.85 \pm 0.03 ~ {\rm (stat)} ~ { }^{+ 0.04}_{-0.05} ~ {\rm (syst)}$ at the stopping target, which is consistent with the SM predictions when the depolarizing effects occurring during the muon production, propagation and moderation in the target are taken into account. The knowledge of beam polarization is of fundamental importance in order to model the background of our ${\megsign}$ search induced by the muon radiative decay: $μ^{+} \rightarrow {\rm e}^{+} \barν_μ ν_{\rm e} γ$.

preprint2016arXiv

Time resolution of time-of-flight detector based on multiple scintillation counters readout by SiPMs

A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $σ_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with multiple counters made of plastic scintillator readout by silicon photomultipliers (SiPMs). The purpose of this work is to demonstrate the time resolution for ~50 MeV/c positrons using prototype counters. Counters with dimensions of $90\times 40\times 5~\mathrm{mm}^3$ readout by six SiPMs (three on each $40\times 5~\mathrm{mm}^2$ plane) were built with SiPMs from Hamamatsu Photonics and AdvanSiD and tested in a positron beam at the DA$Φ$NE Beam Test Facility. The time resolution was found to improve nearly as the square root of the number of counter hits. A time resolution $σ_t=26.2\pm1.3~\mathrm{ps}$ was obtained with eight counters with Hamamatsu SiPMs. These results suggest that the design resolution is achievable in the MEG II experiment.

preprint2015arXiv

HOLMES - The Electron Capture Decay of 163Ho to Measure the Electron Neutrino Mass with sub-eV sensitivity

The European Research Council has recently funded HOLMES, a new experiment to directly measure the neutrino mass. HOLMES will perform a calorimetric measurement of the energy released in the decay of 163Ho. The calorimetric measurement eliminates systematic uncertainties arising from the use of external beta sources, as in experiments with beta spectrometers. This measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only recently the detector technological progress allowed to design a sensitive experiment. HOLMES will deploy a large array of low temperature microcalorimeters with implanted 163Ho nuclei. The resulting mass sensitivity will be as low as 0.4 eV. HOLMES will be an important step forward in the direct neutrino mass measurement with a calorimetric approach as an alternative to spectrometry. It will also establish the potential of this approach to extend the sensitivity down to 0.1 eV. We outline here the project with its technical challenges and perspectives.

preprint2014arXiv

Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results

The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of the single counter elements (SiPMs, scintillators, geometry) is described. Moreover, the results obtained with a first prototype tested at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati (LNF) are presented.

preprint2013arXiv

MEG Upgrade Proposal

We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stopping target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.

preprint2013arXiv

New constraint on the existence of the mu+-> e+ gamma decay

The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% confidence level). This represents a four times more stringent limit than the previous world best limit set by MEG.

preprint2013arXiv

The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU) for Athena+

The Athena+ mission concept is designed to implement the Hot and Energetic Universe science theme submitted to the European Space Agency in response to the call for White Papers for the definition of the L2 and L3 missions of its science program. The Athena+ science payload consists of a large aperture high angular resolution X-ray optics and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), offering 2.5 eV spectral resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter. In this paper, we briefly describe the Athena+ mission concept and the X-IFU performance requirements. We then present the X-IFU detector and readout electronics principles, the current design of the focal plane assembly, the cooling chain and review the global architecture design. Finally, we describe the current performance estimates, in terms of effective area, particle background rejection, count rate capability and velocity measurements. Finally, we emphasize on the latest technology developments concerning TES array fabrication, spectral resolution and readout performance achieved to show that significant progresses are being accomplished towards the demanding X-IFU requirements.

preprint2013arXiv

The MEG detector for $μ+\to e+γ$ decay search

The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and the positron momentum, a timing counter for measuring the positron time, and a liquid xenon detector for measuring the photon energy, position and time. The trigger system, the read-out electronics and the data acquisition system are also presented in detail. The paper is completed with a description of the equipment and techniques developed for the calibration in time and energy and the simulation of the whole apparatus.

preprint2012arXiv

Development and commissioning of the Timing Counter for the MEG Experiment

The Timing Counter of the MEG (Mu to Electron Gamma) experiment is designed to deliver trigger information and to accurately measure the timing of the $e^+$ in searching for the decay $μ^+ \rightarrow e^+γ$. It is part of a magnetic spectrometer with the $μ^+$ decay target in the center. It consists of two sectors upstream and downstream the target, each one with two layers: the inner one made with scintillating fibers read out by APDs for trigger and track reconstruction, the outer one consisting in scintillating bars read out by PMTs for trigger and time measurement. The design criteria, the obtained performances and the commissioning of the detector are presented herein.

preprint2012arXiv

Search for "anomalies" from neutrino and anti-neutrino oscillations at Delta_m^2 ~ 1eV^2 with muon spectrometers and large LAr-TPC imaging detectors

This proposal describes an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN "Far" position. An additional 1/4 of the T600 detector will be constructed and located in the "Near" position. Two spectrometers will be placed downstream of the two LAr-TPC detectors to greatly complement the physics capabilities. Spectrometers will exploit a classical dipole magnetic field with iron slabs, and a new concept air-magnet, to perform charge identification and muon momentum measurements in a wide energy range over a large transverse area. In the two positions, the radial and energy spectra of the nu_e beam are practically identical. Comparing the two detectors, in absence of oscillations, all cross sections and experimental biases cancel out, and the two experimentally observed event distributions must be identical. Any difference of the event distributions at the locations of the two detectors might be attributed to the possible existence of ν-oscillations, presumably due to additional neutrinos with a mixing angle sin^2(2theta_new) and a larger mass difference Delta_m^2_new. The superior quality of the LAr imaging TPC, in particular its unique electron-pi_zero discrimination allows full rejection of backgrounds and offers a lossless nu_e detection capability. The determination of the muon charge with the spectrometers allows the full separation of nu_mu from anti-nu_mu and therefore controlling systematics from muon mis-identification largely at high momenta.

preprint2012arXiv

Search for anomalies in the neutrino sector with muon spectrometers and large LArTPC imaging detectors at CERN

A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed in order to definitely clarify the possible existence of additional neutrino states, as pointed out by neutrino calibration source experiments, reactor and accelerator experiments and measure the corresponding oscillation parameters. The experiment is based on two identical LAr-TPCs complemented by magnetized spectrometers detecting electron and muon neutrino events at Far and Near positions, 1600 m and 300 m from the proton target, respectively. The ICARUS T600 detector, the largest LAr-TPC ever built with a size of about 600 ton of imaging mass, now running in the LNGS underground laboratory, will be moved at the CERN Far position. An additional 1/4 of the T600 detector (T150) will be constructed and located in the Near position. Two large area spectrometers will be placed downstream of the two LAr-TPC detectors to perform charge identification and muon momentum measurements from sub-GeV to several GeV energy range, greatly complementing the physics capabilities. This experiment will offer remarkable discovery potentialities, collecting a very large number of unbiased events both in the neutrino and antineutrino channels, largely adequate to definitely settle the origin of the observed neutrino-related anomalies.

preprint2011arXiv

The Timing Counter of the MEG experiment: calibration and performance

The MEG detector is designed to test Lepton Flavor Violation in the $μ^+\rightarrow e^+γ$ decay down to a Branching Ratio of a few $10^{-13}$. The decay topology consists in the coincident emission of a monochromatic photon in direction opposite to a monochromatic positron. A precise measurement of the relative time $t_{e^+γ}$ is crucial to suppress the background. The Timing Counter (TC) is designed to precisely measure the time of arrival of the $e^+$ and to provide information to the trigger system. It consists of two sectors up and down stream the decay target, each consisting of two layers. The outer one made of scintillating bars and the inner one of scintillating fibers. Their design criteria and performances are described.

preprint2010arXiv

A limit for the mu -> e gamma decay from the MEG experiment

A search for the decay mu -> e gamma, performed at PSI and based on data from the initial three months of operation of the MEG experiment, yields an upper limit on the branching ratio of BR(mu -> e gamma) < 2.8 x 10**-11 (90% C.L.). This corresponds to the measurement of positrons and photons from ~ 10**14 stopped mu-decays by means of a superconducting positron spectrometer and a 900 litre liquid xenon photon detector.