Researcher profile

M. Centis Vignali

M. Centis Vignali contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Beam test results of 25 $μ$m and 35 $μ$m thick FBK UFSD]{Beam test results of 25 $μ$m and 35 $μ$m thick FBK ultra fast silicon detectors

This paper presents the measurements on first very thin Ultra Fast Silicon Detectors (UFSDs) produced by Fondazione Bruno Kessler; the data have been collected in a beam test setup at the CERN PS, using beam with a momentum of 12 GeV/c. UFSDs with a nominal thickness of 25 $μ$m and 35 $μ$m and an area of 1 $\times$ 1 $\text{mm}^2$ have been considered, together with an additional HPK 50-$μ$m thick sensor, taken as reference. Their timing performances have been studied as a function of the applied voltage and gain. A time resolution of about 25 ps and of 22 ps at a voltage of 120 V and 240 V has been obtained for the 25 and 35 $μ$m thick UFSDs, respectively.

preprint2022arXiv

DC-coupled resistive silicon detectors for 4-D tracking

In this work, we introduce a new design concept: the DC-Coupled Resistive Silicon Detectors, based on the LGAD technology. This new approach intends to address a few known features of the first generation of AC-Coupled Resistive Silicon Detectors (RSD). Our simulation exploits a fast hybrid approach based on a combination of two packages, Weightfield2 and LTSpice. It demonstrates that the key features of the RSD design are maintained, yielding excellent timing and spatial resolutions: a few tens of ps and a few microns. In the presentation, we will outline the optimization methodology and the results of the simulation. We will present detailed studies on the effect of changing the ratio between the n+ layer resistivity and the low-resistivity ring and on the achievable temporal and spatial resolution.

preprint2022arXiv

The second production of RSD (AC-LGAD) at FBK

In this contribution we describe the second run of RSD (Resistive AC-Coupled Silicon Detectors) designed at INFN Torino and produced by Fondazione Bruno Kessler (FBK), Trento. RSD are n-in-p detectors intended for 4D particle tracking based on the LGAD technology that get rid of any segmentation implant in order to achieve the 100% fill-factor. They are characterized by three key-elements, (i) a continuous gain implant, (ii) a resistive n-cathode and (iii) a dielectric coupling layer deposited on top, guaranteeing a good spatial reconstruction of the hit position while benefiting from the good timing properties of LGADs. We will start from the very promising results of our RSD1 batch in terms of tracking performances and then we will move to the description of the design of the RSD2 run. In particular, the principles driving the sensor design and the specific AC-electrode layout adopted to optimize the signal confinement will be addressed.

preprint2020arXiv

A novel hybrid microdosimeter for radiation field characterization based on TEPC detector and LGADs tracker: a feasibility study

In microdosimetry, lineal energies y are calculated from energy depositions $ε$ inside the microdosimeter divided by the mean chord length, whose value is based on geometrical assumptions on both the detector and the radiation field. This work presents an innovative two-stages hybrid detector (HDM: hybrid detector for microdosimetry) composed by a Tissue Equivalent Proportional Counter (TEPC) and a silicon tracker made of 4 Low Gain Avalanche Diode (LGAD). This design provides a direct measurement of energy deposition in tissue as well as particles tracking with a submillimeter spatial resolution. The data collected by the detector allow to obtain the real track length traversed by each particle in the TEPC and thus estimates microdosimetry spectra without the mean chord length approximation. Using Geant4 toolkit, we investigated HDM performances in terms of detection and tracking efficiencies when placed in water and exposed to protons and carbon ions in the therapeutic energy range. The results indicate that the mean chord length approximation underestimate particles with short track, which often are characterized by a high energy deposition and thus can be biologically relevant. Tracking efficiency depends on the LGAD configurations: 34 strips sensors have a higher detection efficiency but lower spatial resolution than 71 strips sensors. Further studies will be performed both with Geant4 and experimentally to optimize the detector design on the bases of the radiation field of interest. The main purpose of HDM is to improve the assessment of the radiation biological effectiveness via microdosimetric measurements, exploiting a new definition of the lineal energy ($y_{T}$), defined as the energy deposition $ε$ inside the microdosimeter divided by the real track length of the particle.

preprint2019arXiv

Inverse Low Gain Avalanche Detectors (iLGADs) for precise tracking and timing applications

Low Gain Avalanche Detector (LGAD) is the baseline sensing technology of the recently proposed Minimum Ionizing Particle (MIP) end-cap timing detectors (MTD) at the Atlas and CMS experiments. The current MTD sensor is designed as a multi-pad matrix detector delivering a poor position resolution, due to the relatively large pad area, around 1 $mm^2$; and a good timing resolution, around 20-30 ps. Besides, in his current technological incarnation, the timing resolution of the MTD LGAD sensors is severely degraded once the MIP particle hits the inter-pad region since the signal amplification is missing for this region. This limitation is named as the LGAD fill-factor problem. To overcome the fill factor problem and the poor position resolution of the MTD LGAD sensors, a p-in-p LGAD (iLGAD) was introduced. Contrary to the conventional LGAD, the iLGAD has a non-segmented deep p-well (the multiplication layer). Therefore, iLGADs should ideally present a constant gain value over all the sensitive region of the device without gain drops between the signal collecting electrodes; in other words, iLGADs should have a 100${\%}$ fill-factor by design. In this paper, tracking and timing performance of the first iLGAD prototypes is presented.