Researcher profile

Lenka Halamkova

Lenka Halamkova contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2013arXiv

Enzyme-Based Logic Analysis of Biomarkers at Physiological Concentrations: AND Gate with Double-Sigmoid "Filter" Response

We report the first realization of a biomolecular AND gate function with double-sigmoid response (sigmoid in both inputs). Two enzyme biomarker inputs activate the gate output signal which can then be used as indicating liver injury, but only when both of these inputs have elevated pathophysiological concentrations, effectively corresponding to logic-1 of the binary gate functioning. At lower, normal physiological concentrations, defined as logic-0 inputs, the liver-injury output levels are not obtained. High-quality gate functioning in handling of various sources of noise, on time scales of relevance to potential applications is enabled by utilizing "filtering" effected by a simple added biocatalytic process. The resulting gate response is sigmoid in both inputs when proper system parameters are chosen, and the gate properties are theoretically analyzed within a model devised to evaluate its noise-handling properties.

preprint2013arXiv

Networked Enzymatic Logic Gates with Filtering: New Theoretical Modeling Expressions and Their Experimental Application

We report the first study of a network of connected enzyme-catalyzed reactions, with added chemical and enzymatic processes that incorporate the recently developed biochemical filtering steps into the functioning of this biocatalytic cascade. New theoretical expressions are derived to allow simple, few-parameter modeling of network components concatenated in such cascades, both with and without filtering. The derived expressions are tested against experimental data obtained for the realized network's responses, measured optically, to variations of its input chemicals' concentrations with and without filtering processes. We also describe how the present modeling approach captures and explains several observations and features identified in earlier studies of enzymatic processes when they were considered as potential network components for multi-step information/signal processing systems.

preprint2013arXiv

Two-Input Enzymatic Logic Gates Made Sigmoid by Modifications of the Biocatalytic Reaction Cascades

Computing based on biochemical processes is a newest rapidly developing field of unconventional information and signal processing. In this paper we present results of our research in the field of biochemical computing and summarize the obtained numerical and experimental data for implementations of the standard two-input OR and AND gates with double-sigmoid shape of the output signal. This form of response was obtained as a function of the two inputs in each of the realized biochemical systems. The enzymatic gate processes in the first system were activated with two chemical inputs and resulted in optically detected chromogen oxidation, which happens when either one or both of the inputs are present. In this case, the biochemical system is functioning as the OR gate. We demonstrate that the addition of a "filtering" biocatalytic process leads to a considerable reduction of the noise transmission factor and the resulting gate response has sigmoid shape in both inputs. The second system was developed for functioning as an AND gate, where the output signal was activated only by a simultaneous action of two enzymatic biomarkers. This response can be used as an indicator of liver damage, but only if both of these of the inputs are present at their elevated, pathophysiological values of concentrations. A kinetic numerical model was developed and used to estimate the range of parameters for which the experimentally realized logic gate is close to optimal. We also analyzed the system to evaluate its noise-handling properties.

preprint2011arXiv

Biomolecular Filters for Improved Separation of Output Signals in Enzyme Logic Systems Applied to Biomedical Analysis

Biomolecular logic systems processing biochemical input signals and producing "digital" outputs in the form of YES/NO were developed for analysis of physiological conditions characteristic of liver injury, soft tissue injury and abdominal trauma. Injury biomarkers were used as input signals for activating the logic systems. Their normal physiological concentrations were defined as logic-0 level, while their pathologically elevated concentrations were defined as logic-1 values. Since the input concentrations applied as logic 0 and 1 values were not sufficiently different, the output signals being at low and high values (0, 1 outputs) were separated with a short gap making their discrimination difficult. Coupled enzymatic reactions functioning as a biomolecular signal processing system with a built-in filter property were developed. The filter process involves a partial back-conversion of the optical-output-signal-yielding product, but only at its low concentrations, thus allowing the proper discrimination between 0 and 1 output values.