Researcher profile

Laurent Nony

Laurent Nony contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
13works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2005arXiv

Cu-TBPP and PTCDA molecules on insulating surfaces studied by ultra-high-vacuum non-contact AFM

The adsorption of two kinds of porphyrin (Cu-TBPP) and perylene (PTCDA) derived organic molecules deposited on KBr and Al2O3 surfaces has been studied by non-contact force microscopy in ultra-high vacuum, our goal being the assembly of ordered molecular arrangements on insulating surfaces at room temperature. On a Cu(100) surface, well ordered islands of Cu-TBPP molecules were successfully imaged. On KBr and Al2O3 surfaces, it was found that the same molecules aggregate in small clusters at step edges, rather than forming ordered monolayers. First measurements with PTCDA on KBr show that nanometre-scale rectangular pits in the surface can act as traps to confine small molecular assemblies.

preprint2005arXiv

Dissipation induced by attractive interaction in dynamic force microscopy : contribution of adsorbed water layers

At room temperature and under ambient conditions, due to the adsorption, a water film is always present on silica surfaces. If the surface is investigated with a scanning probe method in Contact mode, this causes the formation of a meniscus between the tip and the surface. This liquid neck generates additional capillary forces between the nano-tip and the surface. In dynamic mode, due to the action of the oscillating tip on the surface, the mechanical response of the adsorbed water layers can induce additional dissipation that is probed through the phase variations of the oscillator. In the present work, we analyze by dynamic force microscopy the growth of a water film on a silica surface as a function of time. The silica sample is first cleaned and heated at $420^\circ$C, then is exposed to dry conditions. The influence of the water film is checked with the dynamic mode by using intermittent contact and noncontact situations. To describe the experimental observations, additional dissipation is taken into account when the tip approaches the surface. The results of the fits allow the evaluation of the dissipation induced by the attractive interaction between the tip and the silica surface related to the adsorption of water molecules on surface as a function of time. Results are compared to previous tribological studies performed in Contact mode and infra-red spectroscopy measurements on the silica for which the key parameter was the surface temperature instead of time. The two experimental results are in good agreement.

preprint2005arXiv

DNA properties investigated by dynamic force microscopy

In this work, we show that by varying the experimental conditions, the driving amplitude, a dynamic force microscope allows DNA properties to be selectively imaged. The substrate on which the DNA is fixed is a silica surface grafted with silanes molecules ended with amine groups. Use of small oscillation amplitudes favors the attractive interaction between the tip and the sample, while use of large amplitudes renders the contribution of the attractive interaction negligible. Particularly, at small amplitudes, the images show that the attractive interaction is strongly enhanced along the DNA. This enhancement is found to be amenable with a model considering a narrow strip of randomly oriented dipoles on each side of the molecule. This work should provide new insights on the DNA interaction and conformational changes with localized charges.

preprint2005arXiv

Growth kinetics of a nanoprotuberance under the action of an oscillating nanotip

The atomic force microscope is a versatile tool that allows many routes to be used for investigating the mechanical properties of soft materials on the nanometer scale. In the present work, experiments were performed on polystyrene polymer films of various molecular weight by approaching a vibrating nanotip towards the surface. The variation of the oscillating amplitude of the cantilever is interpreted as the result of the growth process of a nanoprotuberance. The growth rate is found to be dependent of the magnitude of the oscillating amplitude and of the molecular weight. A model is developed describing in a very simple way the action of the tip and a viscoelastic response of the polymer. The numerical simulation helps in understanding the nonlinear relation between the growth rate and the vibrating amplitude of the microlever and describes qualitatively most of the experimental features. For the softer material, experimental situations are found that allow the experimental results to be amenable with an analytical solution. The analytical solution provides a fruitful comparison with the experimental results showing that some of the nanoprotuberance evolution cannot be explained with the approximation used. The presents results show that there exists a new and fascinating route to better understand the mechanical response at the local scale.

preprint2005arXiv

Influence of noncontact dissipation in the tapping mode: Attempt to extract quantitative information on the surface properties with the local force probe method

In the Tapping mode, a variation of the oscillation amplitude and phase as a function of the tip sample distance is the necessary measurement to access quantitatively to the properties of the surface. In the present work, we give a systematic comparison between experimental data recorded on two surfaces, phase and amplitude, and theoretical curves. With an interaction between the tip and the surface taking into account an attractive and a repulsive term, the analytical approach is unable to properly describe the relationship between the phase variation and the oscillation amplitude variation. When an additional dissipation term is involved, due to the attractive interaction between the tip and the surface, the model gives a good agreement with the recorded data. Particularly, the trends in the phase variations related to the noncontact situations have been found to be amenable to an analysis based upon a simple viscoelastic behavior of the surface.

preprint2005arXiv

Non-contact atomic force microscopy: Stability criterion and dynamical responses of the shift of frequency and damping signal

The aim of this article is to provide a complete analysis of the behavior of a noncontact atomic force microscope (NC-AFM). We start with a review of the equations of motion of a tip interacting with a surface in which the stability conditions are first revisited for tapping mode. Adding the equations of automatic gain control (AGC), which insures constant amplitude of the oscillations in the NC-AFM, to the equations of motion of the tip, a new analytical stability criterion that involves proportional and integral gains of AGC is deduced. Stationary solutions for the shift of frequency and for the damping signal are obtained. Special attention is paid to the damping signal in order to clarify its physical origin. The theoretical results are then compared to those given by a virtual machine. The virtual machine is a set of equations solved numerically without any approximation. The virtual machine is of great help in understanding the dynamical behavior of the NC-AFM as images are recorded. Transient responses of the shift in frequency and of the damping signal are discussed in relation to the values of proportional and integral gains of AGC.

preprint2005arXiv

Nonlinear Dynamic Behavior of an Oscillating Tip-Microlever System and Contrast at the Atomic Scale

In this paper the dynamic behavior of an oscillating tip-microlever system at the proximity of a surface is discussed. We show that the nonlinear behavior of the oscillator is able to explain the high sensitivity of the oscillating tip microlever and the observed shifts of the resonance frequency as a function of the tip surface distance without the need of introducing a particular short range force.

preprint2005arXiv

Nonlinear dynamical properties of an oscillating tip-cantilever system in the tapping mode

The dynamical properties of an oscillating tip-cantilever system are now widely used in the field of scanning force microscopy. The aim of the present work is to get analytical expressions describing the nonlinear dynamical properties of the oscillator in noncontact and intermittent contact situations in the tapping mode. Three situations are investigated: the pure attractive interaction, the pure repulsive interaction, and a mixing of the two. The analytical solutions obtained allow general trends to be extracted: the noncontact and the intermittent contact show a very discriminate variation of the phase. Therefore the measurement of the phase becomes a simple way to identify whether or not the tip touches the surface during the oscillating period. It is also found that the key parameter governing the structure of the dynamical properties is the product of the quality factor by a reduced stiffness. In the attractive regime, the reduced stiffness is the ratio of an attractive effective stiffness and the cantilever one. In the repulsive regime, the reduced stiffness is the ratio between the contact stiffness and the cantilever one. The quality factor plays an important role. For large values of the quality factor; it is predicted that a pure topography can be obtained whatever the value of the contact stiffness. For a smaller quality factor, the oscillator becomes more sensitive to change of the local mechanical properties. As a direct consequence, varying the quality factor, for example with a vacuum chamber, would be a very interesting way to investigate soft materials either to access topographic information or nanomechanical properties.

preprint2005arXiv

Relationship between the non linear dynamic behaviour of an oscillating tip-microlever system and the contrast at the atomic scale

In this paper, the dynamic behaviour of an oscillating tip-microlever system at the proximity of a surface is discussed. The attractive tip-surface interaction is simply described with a Van der Waals dispersive term and a sphere-plane geometry. We show that the non linear behaviour of the oscillator is able to explain the observed shifts of the resonance frequency as a function of the tip-surface distance without the need of introducing a particular short range force.

preprint2005arXiv

Stability analysis of an oscillating tip-cantilever system in NC-AFM

This paper is a theoretical and a numerical investigation of the stability of a tip-cantilever system used in noncontact atomic force microscopy (NC-AFM) when it oscillates close to a surface. No additional dissipative force is considered. The theoretical approach is based on a variational method exploiting a coarse grained operation that gives the temporal dependance of the non-linear coupled equations of motion in amplitude and phase of the oscillator. Stability criterions for the resonance peak are deduced and predict a stable behavior of the oscillator in the vicinity of the resonance. The numerical approach is based on the results obtained with a virtual NC-AFM developed by our group. The effect of the size of the stable domain in phase is investigated. These results are in particularly good agreement with the theoretical predictions. Also they show the influence of the phae shifter in the feedback loop and the way it can affect the damping signal.

preprint2005arXiv

Stability criterions of an oscillating tip-cantilever system in dynamic force microscopy

This work is a theoretical investigation of the stability of the non-linear behavior of an oscillating tip-cantilever system used in dynamic force microscopy. Stability criterions are derived that may help to a better understanding of the instabilities that may appear in the dynamic modes, Tapping and NC-AFM, when the tip is close to a surface. A variational principle allows to get the temporal dependance of the equations of motion of the oscillator as a function of the non-linear coupling term. These equations are the basis for the analysis of the stability. One find that the branch associated to frequencies larger than the resonance is always stable whereas the branch associated to frequencies smaller than the resonance exhibits two stable domains and one unstable. This feature allows to re-interpret the instabilities appearing in Tapping mode and may help to understand the reason why the NC-AFM mode is stable.

preprint2005arXiv

Stability of an oscillating tip in Non-Contact Atomic Force Microscopy: theoretical and numerical investigations

This paper is a theoretical and a numerical investigation of the stability of a tip-cantilever system used in Non-Contact Atomic Force Microscopy (NC-AFM) when it oscillates close to a surface. No additional dissipative force is considered. The theoretical approach is based on a variationnal method exploiting a coarse grained operation that gives the temporal dependence of the nonlinear coupled equations of motion in amplitude and phase of the oscillator. Stability criterions for the resonance peak are deduced and predict a stable behavior of the oscillator in the vicinity of the resonance. The numerical approach is based on results obtained with a virtual NC-AFM developped in our group. The effect of the size of the stable domain in phase is investigated. These results are in particularly good agreement with the theoretical predictions. Also they show the influence of the phase shifter in the feedback loop and the way it can affect the damping signal.

preprint2005arXiv

Structural Characterization of Self-Assembled Monolayers of Organosilanes Chemically Bonded on Silica Wafers by Dynamical Force Microscopy

In this article, a dynamical force microscopy study of self-assembled monolayers of organosilanes, grafted on a silica support, is reported. Organosilanes, terminated either with a functional group (ethylene glycol) or with a methyl group, were used. The influence of the reaction time and the solvent composition on the grafting was investigated to improve the homogeneity of the self-assembled monolayers. Numerical simulations of approach-retract curves, obtained in the tapping mode, were performed and compared to experimental ones. Informations, such as mechanical response and height of the grafted organic layers, have been obtained.