Researcher profile

L. Stringhetti

L. Stringhetti contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
8works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2020arXiv

First detection of the Crab Nebula at TeV energies with a Cherenkov telescope in a dual-mirror Schwarzschild-Couder configuration: the ASTRI-Horn telescope

We report on the first detection of very high-energy (VHE) gamma-ray emission from the Crab Nebula by a Cherenkov telescope in dual-mirror Schwarzschild-Couder (SC) configuration. The result has been achieved by means of the 4 m size ASTRI-Horn telescope, operated on Mt. Etna (Italy) and developed in the context of the Cherenkov Telescope Array Observatory preparatory phase. The dual-mirror SC design is aplanatic and characterized by a small plate scale, allowing us to implement large field of view cameras with small-size pixel sensors and a high compactness. The curved focal plane of the ASTRI camera is covered by silicon photo-multipliers (SiPMs), managed by an unconventional front-end electronics based on a customized peak-sensing detector mode. The system includes internal and external calibration systems, hardware and software for control and acquisition, and the complete data archiving and processing chain. The observations of the Crab Nebula were carried out in December 2018, during the telescope verification phase, for a total observation time (after data selection) of 24.4 h, equally divided into on- and off-axis source exposure. The camera system was still under commissioning and its functionality was not yet completely exploited. Furthermore, due to recent eruptions of the Etna Volcano, the mirror reflection efficiency was reduced. Nevertheless, the observations led to the detection of the source with a statistical significance of 5.4 sigma above an energy threshold of ~3 TeV. This result provides an important step towards the use of dual-mirror systems in Cherenkov gamma-ray astronomy. A pathfinder mini-array based on nine large field-of-view ASTRI-like telescopes is under implementation.

preprint2010arXiv

Cryogenic environment and performance for testing the Planck radiometers

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In this paper the facilities and the related instrumentation are described. The main satellite thermal interfaces for the single chains have to be reproduced and stability requirements have to be satisfied. Setup design, problems occurred and improving solutions implemented are discussed. Performance of the cryogenic setup are reported.

preprint2010arXiv

Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument

We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics. The FEM design is that of a differential pseudo-correlation radiometer in which the signal from the sky is compared with a 4-K blackbody load. The Low Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel phase-switch design which gives excellent amplitude and phase match across the band. The noise temperature requirements are met within the measurement errors at the two frequencies. For the most sensitive LNAs, the noise temperature at the band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively. For some of the FEMs, the noise temperature is still falling as the ambient temperature is reduced to 20 K. Stability tests of the FEMs, including a measurement of the 1/f knee frequency, also meet mission requirements. The 30 and 44 GHz FEMs have met or bettered the mission requirements in all critical aspects. The most sensitive LNAs have reached new limits of noise temperature for HEMTs at their band centres. The FEMs have well-defined linear polarization characteristcs.

preprint2010arXiv

Design, development, and verification of the Planck Low Frequency Instrument 70 GHz Front-End and Back-End Modules

70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and the design details of the mechanical structures are described along with the key InP MMIC low noise amplifiers and phase switches of the units. The units were tested in specially designed cryogenic vacuum chambers capable of producing the operating conditions required for Planck radiometers, specifically, a physical temperature of 20 K for the front-end modules, 300 K for the back-end modules and 4 K for the reference signal sources. Test results of the low noise amplifiers and phase switches, the front and back-end modules, and the combined results of both modules are discussed. At 70 GHz frequency, the system noise temperature of the front and back end is 28 K; the effective bandwidth 16 GHz, and the 1/f spectrum knee frequency is 38 mHz. The test results indicate state-of-the-art performance at 70 GHz frequency and fulfil the Planck performance requirements.

preprint2010arXiv

Level 1 on-ground telemetry handling in Planck LFI

The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekeeping data by sampling regularly the on-board sensors and registers. The housekeeping data provides information on the overall health status of the instrument and on the scientific data quality. The scientific and housekeeping data are collected on-board into telemetry packets compliant with the ESA Packet Telemetry standards. They represent the primary input to the first processing level of the LFI Data Processing Centre. In this work we show the software systems which build the LFI Level 1. A real-time assessment system, based on the ESA SCOS 2000 generic mission control system, has the main purpose of monitoring the housekeeping parameters of LFI and detect possible anomalies. A telemetry handler system processes the housekeeping and scientific telemetry of LFI, generating timelines for each acquisition chain and each housekeeping parameter. Such timelines represent the main input to the subsequent processing levels of the LFI DPC. A telemetry quick-look system allows the real-time visualization of the LFI scientific and housekeeping data, by also calculating quick statistical functions and fast Fourier transforms. The LFI Level 1 has been designed to support all the mission phases, from the instrument ground tests and calibration to the flight operations, and developed according to the ESA engineering standards.

preprint2010arXiv

LFI 30 and 44 GHz receivers Back-End Modules

The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming from the Front End Module are amplified, band pass filtered and finally converted to DC by a detector diode. Each receiver has two identical branches following the differential scheme of the Planck radiometers. The BEM design is based on MMIC Low Noise Amplifiers using GaAs P-HEMT devices, microstrip filters and Schottky diode detectors. Their manufacturing development has included elegant breadboard prototypes and finally qualification and flight model units. Electrical, mechanical and environmental tests were carried out for the characterization and verification of the manufactured BEMs. A description of the 30 and 44 GHz Back End Modules of Planck-LFI radiometers is given, with details of the tests done to determine their electrical and environmental performances. The electrical performances of the 30 and 44 GHz Back End Modules: frequency response, effective bandwidth, equivalent noise temperature, 1/f noise and linearity are presented.

preprint2010arXiv

The linearity response of the Planck-LFI flight model receivers

In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best parameter set representing the receiver response and discuss the impact of non linearity on in-flight calibration, which is shown to be negligible.