Source author record

Kwangwoo Park

Kwangwoo Park appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

Determination of Correction Factors for Small Field Based on Measurement and Numerical Calculation using Cylindrical Ionization Chambers

We studied the investigation of volume averaging effect for air-filled cylindrical ionization chambers to determine correction factors in small photon field for the given chamber. As a method, we measured output factors using several cylindrical ionization chambers and calculated with mathematical method similar to deconvolution in which we modeled non-constant and inhomogeneous exposure function in the cavity of chamber. The parameters in exposure function and correction factors were determined by solving a system of equations we developed with measurement data and geometry of the given chamber. Correction factors (CFs) we had found are very similar to that from Monte Carlo (MC) simulation. For example, CFs in this study were computed as 1.116 for PTW31010, and 1.0225 for PTW31016, while CFs from MC were reported as approximately between 1.17 and 1.20 for PTW31010, and between 1.02 and 1.06 for PTW31016 in of 6MV photon beam . Furthermore, the result from the method of deconvolution combined with MC for chamber response function, also showed similar CF for PTW 30013, which was reported as 2.29 and 1.54 in and filed size respectively. The CFs from our method provided similarly as 2.42 and 1.54. In addition, we reported CFs for PTW30013, PTW31010, PTW31016, IBA FC23-C, and IBA CC13. As a consequence, we suggested a newly developed method to measure correct output factor using the fact that inhomogeneous exposure, force a volume averaging effect in a cavity of air filled cylindrical ionization chamber. The result from this method is very similar to that from MC simulation. The method we developed can easily be applied to clinic.

preprint2010arXiv

Reduction of one-loop n-point integrals

In this paper, we focus on both analytical expressions of three and four point integrals for the case of small Gram determinant and numerical improvement of $n$-point integrals for $n\ge5$. Explicit expressions of three and four-point integrals in the small Gram determinant region are provided by the new method. Furthermore, $n$-point one-loop integral with $n\ge5$ is always reduced to five number of $(n-1)$-point integrals regardless of how many points are on a loop, which improves dramatically the CPU time consuming. Besides, the theoretical and numerical error riginating from computing higher dimensional Cayley matrix could be reduced by the dimension of the matrix being always fixed to five. We suggest a general reduction formulae for five and more point scalar, vector, and tensor integrals at one-loop level.