Researcher profile

Kurt Gibble

Kurt Gibble contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
9works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2013arXiv

Scattering of Cold Atom Coherences by Hot Atoms: Frequency Shifts from Background Gas Collisions

Frequency shifts from background gas collisions currently contribute significantly to the inaccuracy of atomic clocks. Because nearly all collisions with room-temperature background gases that transfer momentum eject the cold atoms from the clock, the interference between the scattered and unscattered waves in the forward direction dominates these frequency shifts. We show they are ~10 times smaller than in room-temperature clocks and that van der Waals interactions produce the cold-atom background-gas shift. General considerations allow the loss of Ramsey fringe amplitude to bound this frequency shift.

preprint2012arXiv

Direct Observation of Resonant Scattering Phase Shifts and their Energy Dependence

We scan the collision energy of two clouds of cesium atoms between 12 and 50 $μ$K in atomic fountain clock. By directly detecting the difference of s-wave scattering phase shifts, we observe a rapid variation of a scattering phase shift through a series of Feshbach resonances. At the energies we use, resonances that overlap at threshold become resolved. Our statistical phase uncertainty of 8 mrad can be improved in future precision measurements of Feshbach resonances to accurately determine the Cs-Cs interactions, which may provide stringent limits on the time variation of fundamental constants.

preprint2012arXiv

Progress in Atomic Fountains at LNE-SYRTE

We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.

preprint2012arXiv

S-Wave Collisional Frequency Shift of a Fermion Clock

We report an s-wave collisional frequency shift of an atomic clock based on fermions. In contrast to bosons, the fermion clock shift is insensitive to the population difference of the clock states, set by the first pulse area in Ramsey spectroscopy, θ_1. The fermion shift instead depends strongly on the second pulse area θ_2. It allows the shift to be canceled, nominally at θ_2 = π/2, but correlations shift the null to slightly larger θ_2. The shift applies to optical lattice clocks and increases with the spatial inhomogeneity of the clock excitation field, naturally large at optical frequencies.

preprint2012arXiv

Spin waves and Collisional Frequency Shifts of a Trapped-Atom Clock

We excite spin-waves with spatially inhomogeneous pulses and study the resulting frequency shifts of a chip-scale atomic clock of trapped $^{87}$Rb. The density-dependent frequency shifts of the hyperfine transition simulate the s-wave collisional frequency shifts of fermions, including those of optical lattice clocks. As the spin polarizations oscillate in the trap, the frequency shift reverses and it depends on the area of the second Ramsey pulse, exhibiting a predicted beyond mean-field frequency shift. Numerical and analytic models illustrate the observed behaviors.

preprint2011arXiv

Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks

We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to delta nu / nu = 8.4\times10^-17. Applying these experimental techniques to clocks with improved microwave cavities will yield negligible distributed cavity phase uncertainties, less than \pm1\times10^-17.

preprint2011arXiv

Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shifts

We evaluate the distributed cavity phase and microwave lensing frequency shifts, which were the two largest sources of uncertainty for the NPL-CsF2 cesium fountain clock. We report measurements that confirm a detailed theoretical model of the microwave cavity fields and the frequency shifts of the clock that they produce. The model and measurements significantly reduce the distributed cavity phase uncertainty to $1.1 \times 10^{-16}$. We derive the microwave lensing frequency shift for a cylindrical cavity with circular apertures. An analytic result with reasonable approximations is given, in addition to a full calculation that indicates a shift of $6.2 \times 10^{-17}$. The measurements and theoretical models we report, along with improved evaluations of collisional and microwave leakage induced frequency shifts, reduce the frequency uncertainty of the NPL-CsF2 standard to $2.3 \times 10^{-16}$, nearly a factor of two lower than its most recent complete evaluation.

preprint2011arXiv

Rydberg Spectroscopy in an Optical Lattice: Blackbody Thermometry for Atomic Clocks

We show that optical spectroscopy of Rydberg states can provide accurate {\em in situ} thermometry at room-temperature. Transitions from a metastable state to Rydberg states with principal quantum numbers of 25 to 30 have 200 times larger fractional frequency sensitivities to blackbody radiation than the Strontium clock transition. We demonstrate that magic wavelength lattices exist for both Strontium and Ytterbium transitions between the metastable and Rydberg states. Frequency measurements of Rydberg transitions with $10^{-16}$ accuracy provide $10 \, \mathrm{mK}$ resolution and yield a blackbody uncertainty for the clock transition of $10^{-18}$.

preprint2010arXiv

Evaluating and Minimizing Distributed Cavity Phase Errors in Atomic Clocks

We perform 3D finite element calculations of the fields in microwave cavities and analyze the distributed cavity phase errors of atomic clocks that they produce. The fields of cylindrical cavities are treated as an azimuthal Fourier series. Each of the lowest components produces clock errors with unique characteristics that must be assessed to establish a clock's accuracy. We describe the errors and how to evaluate them. We prove that sharp structures in the cavity do not produce large frequency errors, even at moderately high powers, provided the atomic density varies slowly. We model the amplitude and phase imbalances of the feeds. For larger couplings, these can lead to increased phase errors. We show that phase imbalances produce a novel distributed cavity phase error that depends on the cavity detuning. We also design improved cavities by optimizing the geometry and tuning the mode spectrum so that there are negligible phase variations, allowing this source of systematic error to be dramatically reduced.