Source author record

Kunal Mankodiya

Kunal Mankodiya appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2016arXiv

A Multi-Smartwatch System for Assessing Speech Characteristics of People with Dysarthria in Group Settings

Speech-language pathologists (SLPs) frequently use vocal exercises in the treatment of patients with speech disorders. Patients receive treatment in a clinical setting and need to practice outside of the clinical setting to generalize speech goals to functional communication. In this paper, we describe the development of technology that captures mixed speech signals in a group setting and allows the SLP to analyze the speech signals relative to treatment goals. The mixed speech signals are blindly separated into individual signals that are preprocessed before computation of loudness, pitch, shimmer, jitter, semitone standard deviation and sharpness. The proposed method has been previously validated on data obtained from clinical trials of people with Parkinson disease and healthy controls.

preprint2016arXiv

BigEAR: Inferring the Ambient and Emotional Correlates from Smartphone-based Acoustic Big Data

This paper presents a novel BigEAR big data framework that employs psychological audio processing chain (PAPC) to process smartphone-based acoustic big data collected when the user performs social conversations in naturalistic scenarios. The overarching goal of BigEAR is to identify moods of the wearer from various activities such as laughing, singing, crying, arguing, and sighing. These annotations are based on ground truth relevant for psychologists who intend to monitor/infer the social context of individuals coping with breast cancer. We pursued a case study on couples coping with breast cancer to know how the conversations affect emotional and social well being. In the state-of-the-art methods, psychologists and their team have to hear the audio recordings for making these inferences by subjective evaluations that not only are time-consuming and costly, but also demand manual data coding for thousands of audio files. The BigEAR framework automates the audio analysis. We computed the accuracy of BigEAR with respect to the ground truth obtained from a human rater. Our approach yielded overall average accuracy of 88.76% on real-world data from couples coping with breast cancer.

preprint2016arXiv

EchoWear: Smartwatch Technology for Voice and Speech Treatments of Patients with Parkinson's Disease

About 90 percent of people with Parkinson's disease (PD) experience decreased functional communication due to the presence of voice and speech disorders associated with dysarthria that can be characterized by monotony of pitch (or fundamental frequency), reduced loudness, irregular rate of speech, imprecise consonants, and changes in voice quality. Speech-language pathologists (SLPs) work with patients with PD to improve speech intelligibility using various intensive in-clinic speech treatments. SLPs also prescribe home exercises to enhance generalization of speech strategies outside of the treatment room. Even though speech therapies are found to be highly effective in improving vocal loudness and speech quality, patients with PD find it difficult to follow the prescribed exercise regimes outside the clinic and to continue exercises once the treatment is completed. SLPs need techniques to monitor compliance and accuracy of their patients exercises at home and in ecologically valid communication situations. We have designed EchoWear, a smartwatch-based system, to remotely monitor speech and voice exercises as prescribed by SLPs. We conducted a study of 6 individuals; three with PD and three healthy controls. To assess the performance of EchoWear technology compared with high quality audio equipment obtained in a speech laboratory. Our preliminary analysis shows promising outcomes for using EchoWear in speech therapies for people with PD. Keywords: Dysarthria; knowledge-based speech processing; Parkinson's disease; smartwatch; speech therapy; wearable system.

preprint2016arXiv

FIT A Fog Computing Device for Speech TeleTreatments

There is an increasing demand for smart fogcomputing gateways as the size of cloud data is growing. This paper presents a Fog computing interface (FIT) for processing clinical speech data. FIT builds upon our previous work on EchoWear, a wearable technology that validated the use of smartwatches for collecting clinical speech data from patients with Parkinson's disease (PD). The fog interface is a low-power embedded system that acts as a smart interface between the smartwatch and the cloud. It collects, stores, and processes the speech data before sending speech features to secure cloud storage. We developed and validated a working prototype of FIT that enabled remote processing of clinical speech data to get speech clinical features such as loudness, short-time energy, zero-crossing rate, and spectral centroid. We used speech data from six patients with PD in their homes for validating FIT. Our results showed the efficacy of FIT as a Fog interface to translate the clinical speech processing chain (CLIP) from a cloud-based backend to a fog-based smart gateway.

preprint2016arXiv

Harmonic Sum-based Method for Heart Rate Estimation using PPG Signals Affected with Motion Artifacts

Wearable photoplethysmography (WPPG) has recently become a common technology in heart rate (HR) monitoring. General observation is that the motion artifacts change the statistics of the acquired PPG signal. Consequently, estimation of HR from such a corrupted PPG signal is challenging. However, if an accelerometer is also used to acquire the acceleration signal simultaneously, it can provide helpful information that can be used to reduce the motion artifacts in the PPG signal. By dint of repetitive movements of the subjects hands while running, the accelerometer signal is found to be quasi-periodic. Over short-time intervals, it can be modeled by a finite harmonic sum (HSUM). Using the harmonic sum (HSUM) model, we obtain an estimate of the instantaneous fundamental frequency of the accelerometer signal. Since the PPG signal is a composite of the heart rate information (that is also quasi-periodic) and the motion artifact, we fit a joint harmonic sum (HSUM) model to the PPG signal. One of the harmonic sums corresponds to the heart-beat component in PPG and the other models the motion artifact. However, the fundamental frequency of the motion artifact has already been determined from the accelerometer signal. Subsequently, the HR is estimated from the joint HSUM model. The mean absolute error in HR estimates was 0.7359 beats per minute (BPM) with a standard deviation of 0.8328 BPM for 2015 IEEE Signal Processing (SP) cup data. The ground-truth HR was obtained from the simultaneously acquired ECG for validating the accuracy of the proposed method. The proposed method is compared with four methods that were recently developed and evaluated on the same dataset.