Researcher profile

Kristin K. Madsen

Kristin K. Madsen contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Reconstruction of the NuSTAR point spread function using single-laser metrology

This paper describes a method by which the metrology system of the Nuclear Spectroscopic Telescope Array (NuSTAR) X-ray space observatory, which uses two lasers to characterize the relative motion of the optics and focal plane benches, can be approximated should one laser fail. The two benches are separated by a ten-meter-long rigid mast that undergoes small amounts of thermal flexing which need to be compensated for in order to produce a non-blurred image. We analyze the trends of mast motion by archival observation parameters in order to discover whether the mast motion in future observations can be predicted. We find that, by using the solar aspect angle (SAA), observation date, and orbital phase, we can simulate the motion of one laser by translating the track produced by the other and applying modifications to the resulting mast aspect solution, allowing the reconstruction of a minimally distorted point spread function in most cases. We will implement the generation of simulated mast files alongside the usual NuSTAR data reduction pipeline for contingency purposes. This work has implications for reducing the risk of implementing laser metrology systems on future missions that use deployable masts to achieve the long focal lengths required in high-energy astronomy by mitigating the impact of a metrology laser failure in the extended phase of a mission.

preprint2021arXiv

StrayCats: A catalog of NuSTAR Stray Light Observations

We present StrayCats: a catalog of NuSTAR stray light observations of X-ray sources. Stray light observations arise for sources 1--4$^{\circ}$ away from the telescope pointing direction. At this off-axis angle, X-rays pass through a gap between optics and aperture stop and so do not interact with the X-ray optics but, instead, directly illuminate the NuSTAR focal plane. We have systematically identified and examined over 1400 potential observations resulting in a catalog of 436 telescope fields and 78 stray light sources that have been identified. The sources identified include historically known persistently bright X-ray sources, X-ray binaries in outburst, pulsars, and Type I X-ray bursters. In this paper we present an overview of the catalog and how we identified the StrayCats sources and the analysis techniques required to produce high level science products. Finally, we present a few brief examples of the science quality of these unique data.

preprint2021arXiv

Timing Calibration of the NuSTAR X-ray Telescope

The Nuclear Spectroscopic Telescope Array (NuSTAR) mission is the first focusing X-ray telescope in the hard X-ray (3-79 keV) band. Among the phenomena that can be studied in this energy band, some require high time resolution and stability: rotation-powered and accreting millisecond pulsars, fast variability from black holes and neutron stars, X-ray bursts, and more. Moreover, a good alignment of the timestamps of X-ray photons to UTC is key for multi-instrument studies of fast astrophysical processes. In this Paper, we describe the timing calibration of the NuSTAR mission. In particular, we present a method to correct the temperature-dependent frequency response of the on-board temperature-compensated crystal oscillator. Together with measurements of the spacecraft clock offsets obtained during downlinks passes, this allows a precise characterization of the behavior of the oscillator. The calibrated NuSTAR event timestamps for a typical observation are shown to be accurate to a precision of ~65 microsec.

preprint2020arXiv

Evidence of Particle Acceleration in the Superbubble 30 Doradus C with NuSTAR

We present evidence of diffuse, non-thermal X-ray emission from the superbubble 30 Doradus C (30 Dor C) using hard X-ray images and spectra from NuSTAR observations. For this analysis, we utilize data from a 200 ks targeted observation of 30 Dor C as well as 2.8 Ms of serendipitous off-axis observations from the monitoring of nearby SN 1987A. The complete shell of 30 Dor C is detected up to 20 keV, and the young supernova remnant MCSNR J0536-6913 in the southeast of 30 Dor C is not detected above 8 keV. Additionally, six point sources identified in previous Chandra and XMM-Newton investigations have hard X-ray emission coincident with their locations. Joint spectral fits to the NuSTAR and XMM-Newton spectra across the 30 Dor C shell confirm the non-thermal nature of the diffuse emission. Given the best-fit rolloff frequencies of the X-ray spectra, we find maximum electron energies of 70-110 TeV (assuming a B-field strength of 4$μ$G), suggesting 30 Dor C is accelerating particles. Particles are either accelerated via diffusive shock acceleration at locations where the shocks have not stalled behind the H$α$ shell, or cosmic-rays are accelerated through repeated acceleration of low-energy particles via turbulence and magnetohydrodynamic waves in the bubble's interior.

preprint2020arXiv

NuSTAR low energy effective area correction due to thermal blanket tear

A rip in the MLI at the exit aperture of OMA, the NuSTAR optic aligned with detector focal plane module FPMA, has resulted in an increased photon flux through OMA that has manifested itself as a low energy excess. Overall, the MLI coverage has decreased by 10%, but there is an additional time-varying component, which occasionally causes the opening to increase by up to 20%. We address the problem with a calibration update, and in this paper, we describe the attributes of the problem, the implications it has on data analysis, and the solution.