Researcher profile

K. Dibert

K. Dibert contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Searching for axion-like time-dependent cosmic birefringence with data from SPT-3G

Ultralight axionlike particles (ALPs) are compelling dark matter candidates because of their potential to resolve small-scale discrepancies between $Λ$CDM predictions and cosmological observations. Axion-photon coupling induces a polarization rotation in linearly polarized photons traveling through an ALP field; thus, as the local ALP dark matter field oscillates in time, distant static polarized sources will appear to oscillate with a frequency proportional to the ALP mass. We use observations of the cosmic microwave background from SPT-3G, the current receiver on the South Pole Telescope, to set upper limits on the value of the axion-photon coupling constant $g_{ϕγ}$ over the approximate mass range $10^{-22} - 10^{-19}$ eV, corresponding to oscillation periods from 12 hours to 100 days. For periods between 1 and 100 days ($4.7 \times 10^{-22} \text{ eV} \leq m_ϕ\leq 4.7 \times 10^{-20} \text{ eV}$), where the limit is approximately constant, we set a median 95% C.L. upper limit on the amplitude of on-sky polarization rotation of 0.071 deg. Assuming that dark matter comprises a single ALP species with a local dark matter density of $0.3\text{ GeV/cm}^3$, this corresponds to $g_{ϕγ} < 1.18 \times 10^{-12}\text{ GeV}^{-1} \times \left( \frac{m_ϕ}{1.0 \times 10^{-21} \text{ eV}} \right)$. These new limits represent an improvement over the previous strongest limits set using the same effect by a factor of ~3.8.

preprint2022arXiv

Strategies for reducing frequency scatter in large arrays of superconducting resonators

Superconducting resonators are now found in a broad range of applications that require high-fidelity measurement of low-energy signals. A common feature across almost all of these applications is the need for increased numbers of resonators to further improve sensitivity, and the ability to read out large numbers of resonators without the need for additional cryogenic complexity is a primary motivation. One of the major limitations of current resonator arrays is the observed scatter in the resonator frequencies when compared to the initial design. Here we present recent progress toward identifying one of the dominant underlying causes of resonator scatter, inductor line width fluctuation. We designed and fabricated an array of lumped-element resonators with inductor line width changing from 1.8um to 2.2um in step of 0.1um defined with electron-beam lithography to probe and quantify the systematic variation of resonance frequency across a 6-inch wafer. The resonators showed a linear frequency shift of 20MHz (140FWHM) and 30MHz (214FWHM), respectively, as they are connected to two different capacitors. This linear relationship matches our theoretical prediction. The widely used MLA photon lithography facility for MKID fabrication has a resolution on the order of 600nm, which could cause frequency fluctuation on the order of 100MHz or 710FWHM.

preprint2022arXiv

The Design and Integrated Performance of SPT-3G

SPT-3G is the third survey receiver operating on the South Pole Telescope dedicated to high-resolution observations of the cosmic microwave background (CMB). Sensitive measurements of the temperature and polarization anisotropies of the CMB provide a powerful dataset for constraining cosmology. Additionally, CMB surveys with arcminute-scale resolution are capable of detecting galaxy clusters, millimeter-wave bright galaxies, and a variety of transient phenomena. The SPT-3G instrument provides a significant improvement in mapping speed over its predecessors, SPT-SZ and SPTpol. The broadband optics design of the instrument achieves a 430 mm diameter image plane across observing bands of 95 GHz, 150 GHz, and 220 GHz, with 1.2 arcmin FWHM beam response at 150 GHz. In the receiver, this image plane is populated with 2690 dual-polarization, tri-chroic pixels (~16000 detectors) read out using a 68X digital frequency-domain multiplexing readout system. In 2018, SPT-3G began a multiyear survey of 1500 deg$^{2}$ of the southern sky. We summarize the unique optical, cryogenic, detector, and readout technologies employed in SPT-3G, and we report on the integrated performance of the instrument.