Researcher profile

K. Bagani

K. Bagani contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - Baseline
5works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2021arXiv

Magnetic, thermal, and topographic imaging with a nanometer-scale SQUID-on-cantilever scanning probe

Scanning superconducting quantum interference device (SQUID) microscopy is a magnetic imaging technique combining high-field sensitivity with nanometer-scale spatial resolution. State-of-the-art SQUID-on-tip probes are now playing an important role in mapping correlation phenomena, such as superconductivity and magnetism, which have recently been observed in two-dimensional van der Waals materials. Here, we demonstrate a scanning probe that combines the magnetic and thermal imaging provided by an on-tip SQUID with the tip-sample distance control and topographic contrast of a non-contact atomic force microscope (AFM). We pattern the nanometer-scale SQUID, including its weak-link Josephson junctions, via focused ion beam milling at the apex of a cantilever coated with Nb, yielding a sensor with an effective diameter of 365 nm, field sensitivity of 9.5 $\text{nT}/\sqrt{\text{Hz}}$ and thermal sensitivity of 620 $\text{nK}/\sqrt{\text{Hz}}$, operating in magnetic fields up to 1.0 T. The resulting SQUID-on-lever is a robust AFM-like scanning probe that expands the reach of sensitive nanometer-scale magnetic and thermal imaging beyond what is currently possible.

preprint2015arXiv

Origin of giant magnetoresistance across the martensitic transformation for Ni44Cu2Mn43In11 alloy: Formation of phase fraction

We have studied the phase volume fraction related magnetoresistance (MR) across the first order martensite transformation (MT) of Ni44Cu2Mn43In11 alloy. Within the metastability of MT, an isothermal application of magnetic field converts the martensite into austenite. The field induced austenite phase fraction (fIA) at any temperature depends on the availability and instability of martensite phase fraction (fM ) at that temperature. This fIA is found to contribute most significantly to the observed giant MR while the contribution from pure martensite and austenite phase fraction is negligible. It is found that the net MR follows a non linear proportional relation with the fIA and the ascending and descending branch of fIA follows different power law giving rise to hysteresis in MR. Here we present a detail explanation of the observed behaviours of MR based on the existing phase fraction.

preprint2013arXiv

Anamolous reduction of magnetic coercivity of graphene oxide and reduced graphene oxide upon cooling

In this report we present the temperature evolution of magnetic coercivity of graphene oxide (GO) and reduced graphene oxide (RGO). We report an anamolous decrease in coercivity of GO and RGO with decreasing temperature. We could explain this anamolous behavior invoking the inherent presence of ripple in graphene. We observe antiferromagnetic and ferromagnetic behavior at room temperature for GO and RGO respectively, but at low temperatures both shows paramagnetic behavior.

preprint2013arXiv

Magnetic hysteresis loop as a probe to distinguish single layer from many layer graphitic structure

In this report we have pointed out that magnetic hysteresis loop can be used as a probe to distinguish a single layer from a many layer graphitic structure. Chemically we have synthesized graphitic oxide (GO) and reduced graphitic oxide (RGO) for this investigation. We observe ferromagnetic like hysteresis loops for both GO and RGO below a certain applied critical magnetic field and above this critical field we observe cross-over of the positive magnetization to negative magnetization leading to diamagnetic behaviour. This cross-over is more dominant for the case of many layer graphitic structure. Upon annealing of GO in air the critical cross-over field decreases and the magnetization increases for multilayer graphitic structure. Possible reasons for all these observations and phenomena is presented here.

preprint2013arXiv

Room temperature operational single electron transistor on the macroscopic surface of hydrogenated diamond like carbon

This paper shows single electron transistor at room temperature,created on macroscopic system-the two-dimensional large area surface of our hydrogenated diamond like carbon thin film. Our results, free from the limitation of lowering the size of coulomb blockade in sub-nanometer range with the existing unprofitable process,are consistent with the theoretical results and will be relevant for future practical applications in the realm of atomic physics, quantum phenomenon and metrology.