Source author record

Juslin Koffi

Juslin Koffi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2010arXiv

Assessment of Pollutant Spread from a Building Basement with three Ventilation Systems

Ventilation aims at providing a sufficient air renewal for ensuring a good indoor air quality (IAQ), yet building energy policies are leading to adapting various ventilation strategies minimising energy losses through air renewal. A recent IAQ evaluation campaign in French dwellings shows important pollution of living spaces by VOCs such as formaldehyde, acetaldehyde or hexanal, particularly in buildings equipped with a garage. Besides, radon emission from soil is a subject of concern in many countries. Several studies are done to understand its release mode and deal with the spread of this carcinogen gas. This paper aims to experimentally assess a contaminant spread from a house basement using mechanical exhaust and balanced ventilation systems, and natural ventilation.

preprint2010arXiv

Experimental Evaluation of Ventilation Systems in a Single-Family Dwelling

The French regulation on residential building ventilation relies on an overall and continuous air renewal. The fresh air should enter the building through the "habitable rooms" while the polluted air is extracted in the service rooms. In this way, internal air is drained from the lowest polluted rooms to the highest polluted ones. However, internal pressure equilibrium and air movements in buildings result from the combined effects ventilation system and parameters such as wind, temperature difference or doors opening. This paper aims to analyse the influence of these parameters on pollutant transfer within buildings. In so doing, experiments are carried out using tracer gas release for representing pollution sources in an experimental house. Mechanical exhaust, balanced and natural ventilation systems are thus tested. Results show the followings: - For all cases, internal doors' opening causes the most important pollutant spread. - When doors are closed, the best performances are obtained with balanced ventilation. - Independently to heating and doors opening, pollutant transfer from lower levels to higher levels of the building is limited in the case of balanced ventilation. - Pollutant spread is quite similar whether the whole building is heated or not.

preprint2010arXiv

Experimental Study of Pollutant Transfer within Dwellings

A mechanical ventilation principle used in French residential buildings was tested in the experimental house of the CSTB research centre. The experiments dealt with pollutant removal efficiency of this ventilation principle, mainly with air tightness and the influence of internal doors. Tracer gas constant injection method was used to simulate the pollution source in the living room. SF6 concentrations were measured in several rooms. The results showed that the air flow routes were in agreement with the theory as long as internal doors were closed. When doors were open, the air pattern was disturbed a lot; a great quantity of the emitted pollutant was measured in the bedrooms. Besides, stack effect promotes the pollutant moving towards the bedrooms under higher indoor-outdoor air temperature differences. In addition, the results showed that if the opening of the bedroom window increases the air change rate, it does not guarantee a good indoor air quality.