Source author record

José Ramos

José Ramos appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

Identification of parameterized gray-box state-space systems: from a black-box linear time-invariant representation to a structured one: detailed derivation of the gradients involved in the cost functions

Estimating consistent parameters of a structured state-space representation requires a reliable initialization when the vector of parameters is computed by using a gradient-based algorithm. In the eponymous companion paper accepted for publication in IEEE Transactions on Automatic Control, the problem of supplying a reliable initial vector of parameters is tackled. More precisely, by assuming that a reliable initial fully-parameterized state-space model of the system is available, the aforementioned paper addresses the challenging problem of transforming this initial fully-parameterized model into the structured state-space parameterization satisfied by the system to be identified. Two solutions to solve such a parameterization problem are more precisely introduced in the IEEE TAC paper. First, a solution based on a null-space-based reformulation of a set of equations arising from the aforementioned similarity transformation problem is considered. Second, an algorithm dedicated to non-convex optimization is presented in order to transform the initial fully-parameterized model into the structured state-space parameterization of the system to be identified. In this technical report, a specific attention is paid to the gradient computation required by the optimization algorithms used in aforementioned to solve the aforementioned problem. These gradient formulations are indeed necessary to apply the quasi-Newton Broyden-Fletcher-Goldfarb-Shanno (BFGS) methods used for the null-space based as well as the least-squares-formulated optimization techniques introduced in the IEEE TAC paper. For the sake of conciseness, we only focus on the smooth version of the optimization problem introduced in aforementioned paper. Interested readers can easily extend the following results by using the chain rule as well as the sub-gradient computation techniques.

preprint2012arXiv

The GRAVITY Coudé Infrared Adaptive Optics (CIAO) system for the VLT Interferometer

GRAVITY is a second generation instrument for the VLT Interferometer, designed to enhance the near-infrared astrometric and spectro-imaging capabilities of VLTI. Combining beams from four telescopes, GRAVITY will provide an astrometric precision of order 10 micro-arcseconds, imaging resolution of 4 milli-arcseconds, and low and medium resolution spectro-interferometry, pushing its performance far beyond current infrared interfero- metric capabilities. To maximise the performance of GRAVITY, adaptive optics correction will be implemented at each of the VLT Unit Telescopes to correct for the effects of atmospheric turbulence. To achieve this, the GRAVITY project includes a development programme for four new wavefront sensors (WFS) and NIR-optimized real time control system. These devices will enable closed-loop adaptive correction at the four Unit Telescopes in the range 1.4-2.4 μm. This is crucially important for an efficient adaptive optics implementation in regions where optically bright references sources are scarce, such as the Galactic Centre. We present here the design of the GRAVITY wavefront sensors and give an overview of the expected adaptive optics performance under typical observing conditions. Benefiting from newly developed SELEX/ESO SAPHIRA electron avalanche photodiode (eAPD) detectors providing fast readout with low noise in the near-infrared, the AO systems are expected to achieve residual wavefront errors of \leq400 nm at an operating frequency of 500 Hz.