Source author record

Jonathan Gibbons

Jonathan Gibbons appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Unidirectional Magnetoresistance in Antiferromagnet/Heavy-metal bilayers

The interplay between electronic transport and antiferromagnetic order has attracted a surge of interest as recent studies have shown that a moderate change in the spin orientation of a collinear antiferromagnet may have a significant effect on the electronic band structure. Among numerous electrical probes to read out such magnetic order, unidirectional magnetoresistance (UMR), where the resistance changes under the reversal of the current direction, can provide rich insights into the transport properties of spin-orbit coupled systems. However, UMR has never been observed in antiferromagnets before, given the absence of intrinsic spin-dependent scattering. Here, we report a UMR in the antiferromagnetic phase of a FeRh$|$Pt bilayer, which undergoes a sign change and then increases strongly with an increasing external magnetic field, in contrast to UMRs in ferromagnetic and nonmagnetic systems. We show that Rashba spin-orbit coupling alone cannot explain the sizable UMR in the antiferromagnetic bilayer and that field-induced spin canting distorts the Fermi contours to greatly enhance the UMR by two orders of magnitude. Our results can motivate the growing field of antiferromagnetic spintronics, and suggest a route to the development of tunable antiferromagnet-based spintronics devices.

preprint2020arXiv

Coherent spin pumping in a strongly coupled magnon-magnon hybrid system

We experimentally identify coherent spin pumping in the magnon-magnon hybrid modes of permalloy/yttrium iron garnet (Py/YIG) bilayers. Using broadband ferromagnetic resonance, an "avoided crossing" is observed between the uniform mode of Py and the spin wave mode of YIG due to the fieldlike interfacial exchange coupling. We also identify additional linewidth suppression and enhancement for the in-phase and out-of-phase hybrid modes, respectively, \textcolor{black}{which can be interpreted as concerted dampinglike torque from spin pumping}. Our analysis predicts inverse proportionality of both fieldlike and dampinglike torques to the square root of the Py thickness, which quantitatively agrees with experiments.

preprint2016arXiv

Scanning SQUID susceptometers with sub-micron spatial resolution

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of $\approx 2μΦ_0/Hz^{1/2}$. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution, but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.

preprint2016arXiv

The response of small SQUID pickup loops to magnetic fields

In the past, magnetic images acquired using scanning Superconducting Quantum Interference Device (SQUID) microscopy have been interpreted using simple models for the sensor point spread function. However, more complicated modeling is needed when the characteristic dimensions of the field sensitive areas in these sensors become comparable to the London penetration depth. In this paper we calculate the response of SQUIDs with deep sub-micron pickup loops to different sources of magnetic fields by solving coupled London's and Maxwell's equations using the full sensor geometry. Tests of these calculations using various field sources are in reasonable agreement with experiments. These calculations allow us to more accurately interpret sub-micron spatial resolution data obtained using scanning SQUID microscopy.