Source author record

Jonathan B. Whitmore

Jonathan B. Whitmore appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2013arXiv

Analysis of Molecular Hydrogen Absorption toward QSO B0642-5038 for a Varying Proton-to-Electron Mass Ratio

Rovibronic molecular hydrogen (H$_2$) transitions at redshift $z_{\rm abs} \simeq 2.659$ towards the background quasar B0642$-$5038 are examined for a possible cosmological variation in the proton-to-electron mass ratio, $μ$. We utilise an archival spectrum from the Very Large Telescope/Ultraviolet and Visual Echelle Spectrograph with a signal-to-noise ratio of $\sim$35 per 2.5-km$\,$s$^{-1}$ pixel at the observed H$_2$ wavelengths (335--410 nm). Some 111 H$_2$ transitions in the Lyman and Werner bands have been identified in the damped Lyman $α$ system for which a kinetic gas temperature of $\sim$84 K and a molecular fraction $\log f = -2.18\pm0.08$ is determined. The H$_2$ absorption lines are included in a comprehensive fitting method, which allows us to extract a constraint on a variation of the proton-electron mass ratio, $Δμ/μ$, from all transitions at once. We obtain $Δμ/μ= (17.1 \pm 4.5_{\rm stat} \pm3.7_{\rm sys})\times10^{-6}$. However, we find evidence that this measurement has been affected by wavelength miscalibration errors recently identified in UVES. A correction based on observations of objects with solar-like spectra gives a smaller $Δμ/μ$ value and contributes to a larger systematic uncertainty: $Δμ/μ= (12.7 \pm 4.5_{\rm stat} \pm4.2_{\rm sys})\times10^{-6}$.

preprint2010arXiv

Wavelength Calibration of the VLT-UVES Spectrograph

We attempt to measure possible miscalibration of the wavelength scale of the VLT-UVES spectrograph. We take spectra of QSO HE0515-4414 through the UVES iodine cell which contains thousands of well-calibrated iodine lines and compare these lines to the wavelength scale from the standard thorium-argon pipeline calibration. Analyzing three exposures of this z = 1.71 QSO, we find two distinct types of calibration shifts needed to correct the Th/Ar wavelength scale. First, there is an overall average velocity shift of between 100 m/s and 500 m/s depending upon the exposure. Second, within a given exposure, we find intra-order velocity distortions of 100 m/s up to more than 200 m/s. These calibration errors are similar to, but smaller than, those found earlier in the Keck HIRES spectrometer. We discuss the possible origins of these two types of miscalibration. We also explore the implications of these calibration errors on the systematic error in measurements of the relative change in alpha (current value - past value) / current value, the change in the fine-structure constant derived from accurate measurement of the relative redshifts of absorption lines in QSO absorption systems. The overall average, exposure-dependent shifts should be less relevant for fine-structure work, but the intra-order shifts have the potential to affect these results. Using either our measured calibration offsets or a Gaussian model with sigma of around 90 m/s, Monte Carlo mock experiments find errors in the relative change in alpha of between 1e-6 Nsys^(-1/2) and 3e-6 Nsys^(-1/2), where Nsys is the number of systems used and the range is due to dependence on how many metallic absorption lines in each system are compared.