Source author record

Jonathan B. Whitmore

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
2topics
4close collaborators

Published work

2 publications

preprint2013arXiv

Analysis of Molecular Hydrogen Absorption toward QSO B0642-5038 for a Varying Proton-to-Electron Mass Ratio

Rovibronic molecular hydrogen (H2_2) transitions at redshift zabs≃2.659z_{\rm abs} \simeq 2.659 towards the background quasar B0642−-5038 are examined for a possible cosmological variation in the proton-to-electron mass ratio, μμ. We utilise an archival spectrum from the Very Large Telescope/Ultraviolet and Visual Echelle Spectrograph with a signal-to-noise ratio of ∼\sim35 per 2.5-km \,s−1^{-1} pixel at the observed H2_2 wavelengths (335--410 nm). Some 111 H2_2 transitions in the Lyman and Werner bands have been identified in the damped Lyman αα system for which a kinetic gas temperature of ∼\sim84 K and a molecular fraction log⁡f=−2.18±0.08\log f = -2.18\pm0.08 is determined. The H2_2 absorption lines are included in a comprehensive fitting method, which allows us to extract a constraint on a variation of the proton-electron mass ratio, Δμ/μΔμ/μ, from all transitions at once. We obtain Δμ/μ=(17.1±4.5stat±3.7sys)×10−6Δμ/μ= (17.1 \pm 4.5_{\rm stat} \pm3.7_{\rm sys})\times10^{-6}. However, we find evidence that this measurement has been affected by wavelength miscalibration errors recently identified in UVES. A correction based on observations of objects with solar-like spectra gives a smaller Δμ/μΔμ/μ value and contributes to a larger systematic uncertainty: Δμ/μ=(12.7±4.5stat±4.2sys)×10−6Δμ/μ= (12.7 \pm 4.5_{\rm stat} \pm4.2_{\rm sys})\times10^{-6}.

preprint2010arXiv

Wavelength Calibration of the VLT-UVES Spectrograph

We attempt to measure possible miscalibration of the wavelength scale of the VLT-UVES spectrograph. We take spectra of QSO HE0515-4414 through the UVES iodine cell which contains thousands of well-calibrated iodine lines and compare these lines to the wavelength scale from the standard thorium-argon pipeline calibration. Analyzing three exposures of this z = 1.71 QSO, we find two distinct types of calibration shifts needed to correct the Th/Ar wavelength scale. First, there is an overall average velocity shift of between 100 m/s and 500 m/s depending upon the exposure. Second, within a given exposure, we find intra-order velocity distortions of 100 m/s up to more than 200 m/s. These calibration errors are similar to, but smaller than, those found earlier in the Keck HIRES spectrometer. We discuss the possible origins of these two types of miscalibration. We also explore the implications of these calibration errors on the systematic error in measurements of the relative change in alpha (current value - past value) / current value, the change in the fine-structure constant derived from accurate measurement of the relative redshifts of absorption lines in QSO absorption systems. The overall average, exposure-dependent shifts should be less relevant for fine-structure work, but the intra-order shifts have the potential to affect these results. Using either our measured calibration offsets or a Gaussian model with sigma of around 90 m/s, Monte Carlo mock experiments find errors in the relative change in alpha of between 1e-6 Nsys^(-1/2) and 3e-6 Nsys^(-1/2), where Nsys is the number of systems used and the range is due to dependence on how many metallic absorption lines in each system are compared.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.