Source author record

John Lewis

John Lewis appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2020arXiv

On a Theorem of Wolff Revisited

We study $p$-harmonic functions, $ 1 < p\neq 2 < \infty$, in $ \mathbb{R}^{2}_+ = \{ z = x + i y : y > 0, - \infty < x < \infty \} $ and $B( 0, 1 ) = \{ z : |z| < 1 \}$. We first show for fixed $ p$, $1 < p\neq 2 < \infty$, and for all large integers $N\geq N_0$ that there exists $p$-harmonic function, $ V = V ( r e^{iθ} )$, which is $ 2π/N $ periodic in the $ θ$ variable, and Lipschitz continuous on $ \partial B (0, 1)$ with Lipschitz norm $\leq c N$ on $ \partial B ( 0, 1 )$ satisfying $V(0)=0$ and $ c^{-1} \leq \int_{-π}^π V ( e^{iθ} ) d θ\leq c$. In case $2<p<\infty $ we give a more or less explicit example of $V$ and our work is an extension of a result of Wolff on $ \mathbb{R}^{2}_+ $ to $ B (0, 1)$. Using our first result, we extend the work of Wolff on failure of Fatou type theorems for $ \mathbb{R}^{2}_+ $ to $ B (0, 1)$ for $p$-harmonic functions, $1< p\neq 2<\infty$. Finally, we also outline the modifications needed for extending the work of Llorente, Manfredi, and Wu regarding failure of subadditivity of $p$-harmonic measure on $ \partial \mathbb{R}^{2}_+ $ to $\partial B (0, 1)$.

preprint2019arXiv

Deep Learning-based Radiomic Features for Improving Neoadjuvant Chemoradiation Response Prediction in Locally Advanced Rectal Cancer

Radiomic features achieve promising results in cancer diagnosis, treatment response prediction, and survival prediction. Our goal is to compare the handcrafted (explicitly designed) and deep learning (DL)-based radiomic features extracted from pre-treatment diffusion-weighted magnetic resonance images (DWIs) for predicting neoadjuvant chemoradiation treatment (nCRT) response in patients with locally advanced rectal cancer (LARC). 43 patients receiving nCRT were included. All patients underwent DWIs before nCRT and total mesorectal excision surgery 6-12 weeks after completion of nCRT. Gross tumor volume (GTV) contours were drawn by an experienced radiation oncologist on DWIs. The patient-cohort was split into the responder group (n=22) and the non-responder group (n=21) based on the post-nCRT response assessed by postoperative pathology, MRI or colonoscopy. Handcrafted and DL-based features were extracted from the apparent diffusion coefficient (ADC) map of the DWI using conventional computer-aided diagnosis methods and a pre-trained convolution neural network, respectively. Least absolute shrinkage and selection operator (LASSO)-logistic regression models were constructed using extracted features for predicting treatment response. The model performance was evaluated with repeated 20 times stratified 4-fold cross-validation using receiver operating characteristic (ROC) curves and compared using the corrected resampled t-test. The model built with handcrafted features achieved the mean area under the ROC curve (AUC) of 0.64, while the one built with DL-based features yielded the mean AUC of 0.73. The corrected resampled t-test on AUC showed P-value < 0.05. DL-based features extracted from pre-treatment DWIs achieved significantly better classification performance compared with handcrafted features for predicting nCRT response in patients with LARC.

preprint2019arXiv

On the capacitive properties of individual microtubules and their meshworks

Microtubules are hollow cylindrical polymers composed of the highly negatively-charged (~23e), high dipole moment (1750 D) protein a,b-tubulin. While the roles of microtubules in chromosomal segregation, macromolecular transport and cell migration are relatively well-understood, studies on the electrical properties of microtubules have only recently gained strong interest. Here, we show that while microtubules at physiological concentrations increase solution capacitance, free tubulin has no appreciable effect. For a particular microtubule concentration, we were able to quantify these effects by determining the capacitance and resistance of a single 20 um-long microtubule to be 1.86 x 10^(-12) F and 1.07 x 10^12 Ohms respectively. Further, we observed a decrease in electrical resistance of solution, with charge transport peaking between 20-60 Hz in the presence of microtubules, consistent with recent findings that microtubules exhibit electric oscillations at such low frequencies. Our results show that in addition to macromolecular transport, microtubules also act as charge-storage devices through counterionic condensation across a broad frequency spectrum. We conclude with a hypothesis of an electrically-tunable cytoskeleton where the dielectric properties of tubulin are polymerization-state dependent.

preprint2015arXiv

$σ$-finiteness of elliptic measures for quasilinear elliptic PDE in space

In this paper we study the Hausdorff dimension of a elliptic measure $μ_{f}$ in space associated to a positive weak solution to a certain quasilinear elliptic PDE in an open subset and vanishing on a portion of the boundary of that open set. We show that this measure is concentrated on a set of $σ-$finite $n-1$ dimensional Hausdorff measure for $p>n$ and the same result holds for $p=n$ with an assumption on the boundary. We also construct an example of a domain in space for which the corresponding measure has Hausdorff dimension $\leq n-1-δ$ for $p\geq n$ for some $δ$ which depends on various constants including $p$. The first result generalizes the authors previous work when the PDE is the $p-$Laplacian and the second result generalizes the well known theorem of Wolff when $p=2$ and $n=2$.

preprint2013arXiv

Hausdorff dimension and $σ$ finiteness of $p-$harmonic measures in space when $p\geq n$

In this paper we study a p harmonic measure, associated with a positive p harmonic function \hat{u} defined in an open set O, subset of R^n, and vanishing on a portion Γof boundary of O. If p>n we show that this p harmonic measure is concentrated on a set of σ- finite H^{n-1} measure while if p=n the same conclusion holds provided Γis uniformly fat in the sense of n capacity.

preprint2010arXiv

GPU-based Fast Low-dose Cone Beam CT Reconstruction via Total Variation

Cone-beam CT (CBCT) has been widely used in image guided radiation therapy (IGRT) to acquire updated volumetric anatomical information before treatment fractions for accurate patient alignment purpose. However, the excessive x-ray imaging dose from serial CBCT scans raises a clinical concern in most IGRT procedures. The excessive imaging dose can be effectively reduced by reducing the number of x-ray projections and/or lowering mAs levels in a CBCT scan. The goal of this work is to develop a fast GPU-based algorithm to reconstruct high quality CBCT images from undersampled and noisy projection data so as to lower the imaging dose. The CBCT is reconstructed by minimizing an energy functional consisting of a data fidelity term and a total variation regularization term. We developed a GPU-friendly version of the forward-backward splitting algorithm to solve this model. A multi-grid technique is also employed. We test our CBCT reconstruction algorithm on a digital NCAT phantom and a head-and-neck patient case. The performance under low mAs is also validated using a physical Catphan phantom and a head-and-neck Rando phantom. It is found that 40 x-ray projections are sufficient to reconstruct CBCT images with satisfactory quality for IGRT patient alignment purpose. Phantom experiments indicated that CBCT images can be successfully reconstructed with our algorithm under as low as 0.1 mAs/projection level. Comparing with currently widely used full-fan head-and-neck scanning protocol of about 360 projections with 0.4 mAs/projection, it is estimated that an overall 36 times dose reduction has been achieved with our algorithm. Moreover, the reconstruction time is about 130 sec on an NVIDIA Tesla C1060 GPU card, which is estimated ~100 times faster than similar iterative reconstruction approaches.

preprint2010arXiv

PCA-based lung motion model

Organ motion induced by respiration may cause clinically significant targeting errors and greatly degrade the effectiveness of conformal radiotherapy. It is therefore crucial to be able to model respiratory motion accurately. A recently proposed lung motion model based on principal component analysis (PCA) has been shown to be promising on a few patients. However, there is still a need to understand the underlying reason why it works. In this paper, we present a much deeper and detailed analysis of the PCA-based lung motion model. We provide the theoretical justification of the effectiveness of PCA in modeling lung motion. We also prove that under certain conditions, the PCA motion model is equivalent to 5D motion model, which is based on physiology and anatomy of the lung. The modeling power of PCA model was tested on clinical data and the average 3D error was found to be below 1 mm.