Source author record

Johannes Schiffer

Johannes Schiffer appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Dynamic state and parameter estimation in multi-machine power systems - Experimental demonstration using real-world PMU-measurements

Dynamic state and parameter estimation (DSE) plays a key role for reliably monitoring and operating future, power-electronics-dominated power systems. While DSE is a very active research field, experimental applications of proposed algorithms to real-world systems remain scarce. This motivates the present paper, in which we demonstrate the effectiveness of a DSE algorithm previously presented by parts of the authors with real-world data collected by a Phasor Measurement Unit (PMU) at a substation close to a power plant within the extra-high voltage grid of Germany. To this end, at first we derive a suitable mapping of the real-world PMU-measurements recorded at a substation close to the power plant to the terminal bus of the power plants' synchronous generator (SG). This mapping considers the high-voltage (HV) transmission line, the tap-changing transformer and the auxiliary system of the power plant. Next, we introduce several practically motivated extensions to the estimation algorithm, which significantly improve its practical performance with real-world measurements. Finally, we successfully validate the algorithm experimentally in an auto- as well as a cross-validation.

preprint2022arXiv

PMU-based dynamic state and parameter estimation for dynamic security assessment in power systems -- Ultimate boundedness in the presence of measurement noise

Dynamic state and parameter estimation methods for dynamic security assessment in power systems are becoming increasingly important for system operators. Usually, the data used for this type of applications stems from phasor measurement units (PMUs) and is corrupted by noise. In general, the impact of the latter may significantly deteriorate the estimation performance. This motivates the present work, in which it is proven that the state and parameter estimation method proposed by part of the authors in [1] and extended in [2] features the property that the estimation errors are ultimately bounded in the presence of PMU measurement data corrupted by bounded noise. The analysis is conducted for the third-order flux-decay model of a synchronous generator and holds independently of the employed automatic voltage regulator and power system stabilizer (if present). The analysis is illustrated by simulations.

preprint2020arXiv

A Globally Convergent State Observer for Multimachine Power Systems with Lossy Lines

We present the first solution to the problem of estimation of the state of multimachine power systems with lossy transmission lines. We consider the classical three-dimensional \fluxdecay" model of the power system and assume that the active and reactive power as well as the rotor angle and excitation voltage at each generator is available for measurement|a scenario that is feasible with current technology. The design of the observer relies on two recent developments proposed by the authors: a parameter estimation based approach to the problem of state estimation and the use of the dynamic regressor extension and mixing technique to estimate these parameters. Thanks to the combination of these techniques it is possible to overcome the problem of lack of persistent excitation that stymies the application of standard observer designs. Simulation results illustrate the performance of the proposed observer.

preprint2020arXiv

State Observation of Power Systems Equipped with Phasor Measurement Units: The Case of Fourth Order Flux-Decay Model

The problem of effective use of Phasor Measurement Units (PMUs) to enhance power systems awareness and security is a topic of key interest. The central question to solve is how to use this new measurements to reconstruct the state of the system. In this paper we provide the first solution to the problem of (globally convergent) state estimation of multimachine power systems equipped with PMUs and described by the fourth order flux-decay model. This work is a significant extension of our previous result, where this problem was solved for the simpler third order model, for which it is possible to recover algebraically part of the unknown state. Unfortunately, this property is lost in the more accurate fourth order model, significantly complicating the state observation task. The design of the observer relies on two recent developments proposed by the authors, a parameter estimation based approach to the problem of state estimation and the use of the Dynamic Regressor Extension and Mixing (DREM) technique to estimate these parameters. The use of DREM allows us to overcome the problem of lack of persistent excitation that stymies the application of standard parameter estimation designs. Simulation results illustrate the latter fact and show the improved performance of the proposed observer with respect to a locally stable gradient-descent based observer.

preprint2016arXiv

A survey on modeling of microgrids - from fundamental physics to phasors and voltage sources

Microgrids have been identified as key components of modern electrical systems to facilitate the integration of renewable distributed generation units. Their analysis and controller design requires the development of advanced (typically model-based) techniques naturally posing an interesting challenge to the control community. Although there are widely accepted reduced order models to describe the dynamic behavior of microgrids, they are typically presented without details about the reduction procedure---hampering the understanding of the physical phenomena behind them. Preceded by an introduction to basic notions and definitions in power systems, the present survey reviews key characteristics and main components of a microgrid. We introduce the reader to the basic functionality of DC/AC inverters, as well as to standard operating modes and control schemes of inverter-interfaced power sources in microgrid applications. Based on this exposition and starting from fundamental physics, we present detailed dynamical models of the main microgrid components. Furthermore, we clearly state the underlying assumptions which lead to the standard reduced model with inverters represented by controllable voltage sources, as well as static network and load representations, hence, providing a complete modular model derivation of a three-phase inverter-based microgrid.