Researcher profile

Jingke Zhang

Jingke Zhang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Deep Learning Improves Dataset Recovery for High Frame Rate Synthetic Transmit Aperture Imaging

Synthetic transmit aperture (STA) imaging can achieve optimal lateral resolution in the full field of view, at the cost of low frame rate (FR) and low signal-to-noise ratio (SNR). In our previous studies, compressed sensing based synthetic transmit aperture (CS-STA) and minimal l2-norm least squares (LS-STA) methods were proposed to recover the complete STA dataset from fewer Hadamard-encoded plane wave (PW) transmissions. Results demonstrated that, compared with STA imaging, CS/LS-STA can maintain the high resolution of STA and improve the contrast in the deep region with increased FR. However, these methods would introduce errors to the recovered STA datasets and subsequently produce severe artifacts to the beamformed images. Recently, we discovered that the theoretical explanation for the error introduced in the LS-STA-based recovery is that LS-STA method neglects the null space component of the real STA data. To deal with this problem, we propose to train a convolutional neural network (CNN) under the null space learning framework (to estimate the missing null space component) for high-accuracy recovery of the STA dataset from fewer Hadamard-encoded PW transmissions. The mapping between the low-quality STA dataset (recovered using the LS-STA method) and the corresponding high-quality STA dataset (obtained using full Hadamard-encoded STA imaging, HE-STA) was learned from phantom and in vivo samples. The performance of the proposed CNN-STA method was compared with the LS-STA, STA, and HE-STA methods, in terms of visual quality, NRMSE, gCNR, and FWHM. The results demonstrate that the proposed method can improve the recovery accuracy of the STA datasets and therefore effectively suppress the artifacts presented in the images obtained using the LS-STA method. In addition, the proposed method can maintain the high lateral resolution of STA with fewer PW transmissions, as LS-STA does.

preprint2021arXiv

Partial Hadamard Encoded Synthetic Transmit Aperture for High Frame Rate Imaging with Minimal l2-Norm Least Square Method

Synthetic transmit aperture (STA) ultrasound imaging is well known for ideal focusing in the full field of view. However, it suffers from low signal-to-noise ratio (SNR) and low frame rate, because each array element must be activated individually. In our previous study, we encoded all the array elements with partial Hadamard matrix and reconstructed the complete STA dataset with compressed sensing (CS) algorithm (CS-STA). As all the elements are activated in each transmission and the number of transmissions is smaller than that of STA, this method can achieve higher SNR and higher frame rate. Its main drawback is the time-consuming CS reconstruction. In this study, we accelerate the complete STA dataset reconstruction with minimal l2-norm least square method. Thanks of the orthogonality of partial Hadamard matrix, the minimal l2-norm least square solution can be easily calculated. The proposed method is tested with simulation data and experimental phantom and in-vivo data. The results demonstrate that the proposed method achieves ~5*10^3 times faster reconstruction speed than CS algorithm. The simulation results demonstrate that the proposed method is capable of achieving the same accuracy for STA dataset reconstruction as conventional CS-STA method. The simulations, phantom and in-vivo experiments show that the proposed method is capable of improving the generalized contrast-to-noise ratio (gCNR) and SNR with maintained spatial resolution and fewer transmissions, compared with STA. In conclusion, the improved image quality and reduced computational time of LS-STA pave the way for its real-time applications in the clinics.