Researcher profile

Jianren Fan

Jianren Fan contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

An adaptive primitive-conservative scheme for high speed transcritical flow with an arbitrary equation of state

When fully conservative methods are used to simulate transcritical flow, spurious pressure oscillations and numerical instability are generated. The strength and speed of propagation of shock waves cannot be represented correctly using a semi-conservative or primitive method. In this research, an adaptive primitive-conservative scheme is designed to overcome the aforesaid two difficulties. The underlying cause for pressure oscillation is analyzed within the framework of Finite Volume Method (FVM). We found that the nonlinearity of the thermodynamic properties of transcritical fluids renders standard conservative numerical methods ineffective. In smooth regions, schemes based on primitive variable are used to eliminate spurious pressure oscillations. For the purpose of correctly capturing shock waves, the modified Roe Riemann solver for real fluid is utilized in regions where shock waves induce discontinuity. The adaptive numerical approach relies only on the speed of sound, eliminating the requirement to calculate the derivatives of thermodynamic quantities. A large number of numerical test cases conducted in one- and two-dimensional spaces have shown the robustness and accuracy of the proposed adaptive scheme for the simulations of high speed transcritical flows.

preprint2022arXiv

Molecular dynamics simulation of flow around a circular nano-cylinder

In this study, the wake flow around a circular nano-cylinder is numerically investigated with molecular dynamics simulation to reveal the micro/nano size effect on the wake flow. The cavitation occurring when Reynolds number (Re) > 101 can effectively influence the wake flow. The Strouhal number (St) of the wake flow increases with the Re at low Re, but steadily decreases with the Re after the cavitation appears. The dominant frequency of the lift force fluctuation can be higher than that of the velocity fluctuation, and be drowned in the chaotic fluctuating background of the Brownian forces when Re {\geq} 127. Also because of the strong influence of the Brownian forces, no dominant frequency of the drag force fluctuation can be observed. The Jz number, which is defined as the ratio between the mean free path λ of the fluid molecules and the equilibrium distance of potential energy σ, is newly introduced in order to consider the internal size effect of fluid. The St of the wake flow increases with the Jz until it falls to zero sharply when Jz {\approx} 1.7. It denotes the discontinuity of the fluid can eventually eliminate the vortex generation and shedding. Meanwhile, the St decreases with the Kn because of the intensification of the cavitation.

preprint2021arXiv

Fluid structure interaction: Insights into biomechanical implications of endograft after thoracic endovascular aortic repair

Thoracic endovascular aortic repair (TEVAR) has developed to be the most effective treatment for aortic diseases. This study aims to evaluate the biomechanical implications of the implanted endograft after TEVAR. We present a novel image-based, patient-specific, fluid-structure computational framework. The geometries of blood, endograft, and aortic wall were reconstructed based on clinical images. Patient-specific measurement data was collected to determine the parameters of the three-element Windkessel. We designed three postoperative scenarios with rigid wall assumption, blood-wall interaction, blood-endograft-wall interplay, respectively, where a two-way fluid-structure interaction (FSI) method was applied to predict the deformation of the composite stent-wall. Computational results were validated with Doppler ultrasound data. Results show that the rigid wall assumption fails to predict the waveforms of blood outflow and energy loss (EL). The complete storage and release process of blood flow energy, which consists of four phases is captured by the FSI method. The endograft implantation would weaken the buffer function of the aorta and reduce mean EL by 19.1%. The closed curve area of wall pressure and aortic volume could indicate the EL caused by the interaction between blood flow and wall deformation, which accounts for 68.8% of the total EL. Both the FSI and endograft have a slight effect on wall shear stress-related-indices. The deformability of the composite stent-wall region is remarkably limited by the endograft. Our results highlight the importance of considering the interaction between blood flow, the implanted endograft, and the aortic wall to acquire physiologically accurate hemodynamics in post-TEVAR computational studies and the deformation of the aortic wall is responsible for the major EL of the blood flow.

preprint2021arXiv

Hemodynamic effects of stent-graft introducer sheath during thoracic endovascular aortic repair

Thoracic endovascular aortic repair (TEVAR) has become the standard treatment of a variety of aortic pathologies. The objective of this study is to evaluate the hemodynamic effects of stent-graft introducer sheath during TEVAR. Three idealized representative diseased aortas of aortic aneurysm, coarctation of the aorta, and aortic dissection were designed. Computational fluid dynamics studies were performed in the above idealized aortic geometries. An introducer sheath routinely used in the clinic was virtually-delivered into diseased aortas. Comparative analysis was carried out to evaluate the hemodynamic effects of the introducer sheath. Results show that the blood flow to the supra-aortic branches would increase above 9% due to the obstruction of the introducer sheath. The region exposed to high endothelial cell activation potential (ECAP) expands in the scenarios of coarctation of the aorta and aortic dissection, which indicates that the probability of thrombus formation may increase during TEVAR. The pressure magnitude in peak systole shows an obvious rise and a similar phenomenon is not observed in early diastole. The blood viscosity in the aortic arch and descending aorta is remarkably altered by the introducer sheath. The uneven viscosity distribution confirms the necessity of using non-Newtonian models and high viscosity region with high ECAP further promotes thrombosis. Our results highlight the hemodynamic effects of stent-graft introducer sheath during TEVAR, which may associate with perioperative complications.

preprint2021arXiv

Mathematical modeling of shear-activated targeted nanoparticle drug delivery for the treatment of aortic diseases

The human aorta is a high-risk area for vascular diseases, which are commonly restored by thoracic endovascular aortic repair. In this paper, we report a promising shear-activated targeted nanoparticle drug delivery strategy to assist in the treatment of coarctation of the aorta and aortic aneurysm. Idealized three-dimensional geometric models of coarctation of the aorta and aortic aneurysm are designed, respectively. The unique hemodynamic environment of the diseased aorta is used to improve nanoparticle drug delivery. Micro-carriers with nanoparticle drugs would be targeting activated to release nanoparticle drugs by local abnormal shear stress rate (SSR). Coarctation of the aorta provides a high SSR hemodynamic environment, while the aortic aneurysm is exposed to low SSR. We propose a method to calculate the SSR thresholds for the diseased aorta. Results show that the upstream near-wall area of the diseased location is an ideal injection location for the micro-carriers, which could be activated by the abnormal SSR. Released nanoparticle drugs would be successfully targeted delivered to the aortic diseased wall. Besides, the high diffusivity of the micro-carriers and nanoparticle drugs has a significant impact on the surface drug concentrations of the diseased aortic walls, especially for aortic aneurysms. This study preliminary demonstrates the feasibility of shear-activated targeted nanoparticle drug delivery in the treatment of aortic diseases and provides a theoretical basis for developing the drug delivery system and novel therapy.