Source author record

Jianfeng Ji

Jianfeng Ji appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

A Transmissive X-ray Polarimeter Design For Hard X-ray Focusing Telescopes

The X-ray Timing and Polarization (XTP) is a mission concept for a future space borne X-ray observatory and is currently selected for early phase study. We present a new design of X-ray polarimeter based on the time projection gas chamber. The polarimeter, placed above the focal plane, has an additional rear window that allows hard X-rays to penetrate (a transmission of nearly 80% at 6 keV) through it and reach the detector on the focal plane. Such a design is to compensate the low detection efficiency of gas detectors, at a low cost of sensitivity, and can maximize the science return of multilayer hard X-ray telescopes without the risk of moving focal plane instruments. The sensitivity in terms of minimum detectable polarization, based on current instrument configuration, is expected to be 3% for a 1mCrab source given an observing time of 10^5 s. We present preliminary test results, including photoelectron tracks and modulation curves, using a test chamber and polarized X-ray sources in the lab.

preprint2011arXiv

A Large Area LaBr3/NaI Phoswich for Hard X-ray Astronomy

In terms of energy resolution, temporal response to burst events, and thermal stability, lanthanum bromide doped with Ce is a much better choice than the traditional NaI(Tl) scintillator for hard X-ray astronomy. We present the test results of a phoswich detector with a diameter of 101.6 mm consisting of 6 mm thick LaBr3:Ce and 40 mm thick NaI(Tl), which is the largest one of this type reported so far. The measured energy resolution is 10.6% at 60 keV, varying inversely proportional to the square root of the energy, and the energy nonlinearity is found to be less than 1%, as good as those of smaller phoswiches. The coupled scintillators and phototube also show excellent uniformity across the detecting surface, with a deviation of 0.7% on the pulse amplitude produced by 60 keV gamma-rays. Thanks to the large ratio of light decay times of NaI(Tl) and LaBr3:Ce, 250 ns vs. 16 ns, pulse shape discrimination is much easier for this combination than for NaI(Tl)/CsI(Na). As the light decay time of LaBr3:Ce is about 15 times faster than that of NaI(Tl), this phoswich is more suitable for detection of bright, transient sources such as gamma-ray bursts and soft gamma-ray repeaters. The internal activity of lanthanum produces a count rate of about 6 counts/s at 37.5 keV in the detector. This peak could be used for in-flight spectral calibration and gain correction.