Researcher profile

Jian-Hua Liu

Jian-Hua Liu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2020arXiv

Polarization and fundamental sensitivity of $^{\text{39}}$K ($^{\text{133}}$Cs)-$^{\text{85}}$Rb-$^{\text{21}}$Ne co-magnetometers

The hybrid optical pumping spin exchange relaxation free (HOPSERF) atomic co-magnetometers make ultrahigh sensitivity measurement of inertia achievable. The wall relaxation rate has a big effect on the polarization and fundamental sensitivity for the co-magnetometer, but it is often neglected in the experiments. However, there is almost no work about the systematic analysis of the influence factors on the polarization and the fundamental sensitivity of the HOPSERF co-magnetometers. Here, we systematically study the polarization and the fundamental sensitivity of 39K-85Rb-21Ne and 133Cs-85Rb-21Ne HOPSERF co-magnetometers with low polarization limit and the wall relaxation rate. The 21Ne number density, the power density and wavelength of pump beam will affect the polarization greatly by affecting the pumping rate of pump beam. We obtain a general formula on the fundamental sensitivity of the HOPSERF co-magnetometers due to shot-noise and the fundamental sensitivity changes with multiple systemic parameters, where the suitable number density of buffer gas and quench gas make the fundamental sensitivity highest. The fundamental sensitivity $7.5355\times10^{-11}$ $\rm rad/s/Hz^{1/2}$ of 133Cs-85Rb-21Ne co-magnetometer is higher than the ultimate theoretical sensitivity $2\times10^{-10}$ $\rm rad/s/Hz^{1/2}$ of K-21Ne co-magnetometer.