Published work

3 published item(s)

preprint2016arXiv

Genie: A Longitudinal Study Comparing Physical and Software-augmented Thermostats in Office Buildings

Thermostats are primary interfaces for occupants of office buildings to express their comfort preferences. However, standard thermostats are often ineffective due to inaccessibility, lack of information, or limited responsiveness, leading to occupant discomfort. Software thermostats based on web or smartphone applications provide alternative interfaces to occupants with minimal deployment cost. However, their usage and effectiveness have not been studied extensively in real settings. In this paper we present Genie, a novel software-augmented thermostat that we deployed and studied at our university over a period of 21 months. Our data shows that providing wider thermal control to users does not lead to system abuse and that the effect on energy consumption is minimal while improving comfort and energy awareness. We believe that increased introduction of software thermostats in office buildings will have important effects on comfort and energy consumption and we provide key design recommendations for their implementation and deployment.

preprint2016arXiv

Quiver: Using Control Perturbations to Increase the Observability of Sensor Data in Smart Buildings

Modern buildings consist of hundreds of sensors and actuators for monitoring and operation of systems such as HVAC, light and security. To enable portable applications in next generation smart buildings, we need models and standardized ontologies that represent these sensors across diverse types of buildings. Recent research has shown that extracting information such as sensor type with available metadata and timeseries data analysis is difficult due to heterogeneity of systems and lack of support for interoperability. We propose perturbations in the control system as a mechanism to increase the observability of building systems to extract contextual information and develop standardized models. We design Quiver, an experimental framework for actuation of building HVAC system that enables us to perturb the control system safely. Using Quiver, we demonstrate three applications using empirical experiments on a real commercial building: colocation of data points, identification of point type and mapping of dependency between actuators. Our results show that we can colocate data points in HVAC terminal units with 98.4 % accuracy and 63 % coverage. We can identify point types of the terminal units with 85.3 % accuracy. Finally, we map the dependency links between actuators with an accuracy of 73.5 %, with 8.1 % and 18.4 % false positives and false negatives respectively.

preprint2015arXiv

HVACMeter: Apportionment of HVAC Power to Thermal Zones and Air Handler Units

Heating, Ventilation and Air Conditioning (HVAC) systems consume almost half of the total energy use of commercial buildings. To optimize HVAC energy usage, it is important to understand the energy consumption of individual HVAC components at fine granularities. However, buildings typically only have aggregate building level power and thermal meters. We present HVACMeter, a system which leverages existing sensors in commercial HVAC systems to estimate the energy consumed by individual components of the HVAC system, as well by each thermal zone in buildings. HVACMeter can be generalized to any HVAC system as it uses the basic understanding of HVAC operation, heat transfer equations, and historical sensor data to estimate energy. We deploy HVACMeter to three buildings on our campus, to identify the set of sensors that are important for accurately disaggregating energy use at the level of each Air Handler Unit and each thermal zone within these buildings. HVACMeter power estimations have on an average 44.5 % less RMSE than that of mean power estimates. Furthermore, we highlight the usefulness of HVACMeter energy estimation model for a building fault detection application by quantifying the amount of energy that can be saved by fixing particular faults.