Source author record

Jamison Noenickx

Jamison Noenickx appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

The conceptual design of GMagAO-X: visible wavelength high contrast imaging with GMT

We present the conceptual design of GMagAO-X, an extreme adaptive optics system for the 25 m Giant Magellan Telescope (GMT). We are developing GMagAO-X to be available at or shortly after first-light of the GMT, to enable early high contrast exoplanet science in response to the Astro2020 recommendations. A key science goal is the characterization of nearby potentially habitable terrestrial worlds. GMagAO-Xis a woofer-tweeter system, with integrated segment phasing control. The tweeter is a 21,000 actuator segmented deformable mirror, composed of seven 3000 actuator segments. A multi-stage wavefront sensing system provides for bootstrapping, phasing, and high order sensing. The entire instrument is mounted in a rotator to provide gravity invariance. After the main AO system, visible (g to y) and near-IR (Y to H) science channels contain integrated coronagraphic wavefront control systems. The fully corrected and, optionally, coronagraphically filtered beams will then be fed to a suite of focal plane instrumentation including imagers and spectrographs. This will include existing facility instruments at GMT via fiber feeds. To assess the design we have developed an end-to-end frequency-domain modeling framework for assessing the performance of GMagAO-X. The dynamics of the many closed-loop feedback control systems are then modeled. Finally, we employ a frequency-domain model of post-processing algorithms to analyze the final post-processed sensitivity. The CoDR for GMagAO-X was held in September, 2021. Here we present an overview of the science cases, instrument design, expected performance, and concept of operations for GMagAO-X.

preprint2022arXiv

The Optical and Mechanical Design for the 21,000 Actuator ExAO System for the Giant Magellan Telescope: GMagAO-X

GMagAO-X is the near first light ExAO coronagraphic instrument for the 25.4m GMT. It is designed for a slot on the folded port of the GMT. To meet the strict ExAO fitting and servo error requirement (<90nm rms WFE), GMagAO-X must have 21,000 actuator DM capable of >2KHz correction speeds. To minimize wavefront/segment piston error GMagAO-X has an interferometric beam combiner on a vibration isolated table, as part of this "21,000 actuator parallel DM". Piston errors are sensed by a Holographic Dispersed Fringe Sensor (HDFS). In addition to a coronagraph, it has a post-coronagraphic Lyot Low Order WFS (LLOWFS) to sense non-common path (NCP) errors. The LLOWFS drives a non-common path DM (NCP DM) to correct those NCP errors. GMagAO-X obtains high-contrast science and wavefront sensing in the visible and/or the NIR. Here we present our successful externally reviewed (Sept. 2021) CoDR optical-mechanical design that satisfies GMagAO-X's top-level science requirements and is compliant with the GMT instrument requirements and only requires COTS parts.