Source author record

James Luke Webb

James Luke Webb appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Microscopic-scale recording of brain neuronal electrical activity using a diamond quantum sensor

An important tool in the investigation of the early stages of neurodegenerative disease is the study of dissected living tissue from the brain of an animal model. Such investigations allow the physical structure of individual neurons and neural circuits to be probed alongside neuronal electrical activity, disruption of which can shed light on the mechanisms of emergence of disease. Existing techniques for recording activity rely on potentially damaging direct interaction with the sample, either mechanically as point electrical probes or via intense focused laser light combined with highly specific genetic modification and/or potentially toxic fluorescent dyes. In this work, we instead perform passive, microscopic-scale recording of electrical activity using a biocompatible quantum sensor based on colour centres in diamond. We record biomagnetic field induced by ionic currents in mouse corpus callosum axons without direct sample interaction, accurately recovering signals corresponding to action potential propagation while demonstrating in situ pharmacology during biomagnetic recording through tetrodotoxin inhibition of voltage gated sodium channels. Our results open a promising new avenue for the microscopic recording of neuronal signals, offering the prospect of high resolution imaging of electrical circuits in the living mammalian brain.

preprint2020arXiv

Detection of biological signals from a live mammalian muscle using a diamond quantum sensor

The ability to perform noninvasive, non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconducting detectors. These have many disadvantages in terms of high cost, flexibility and limited portability as well as poor spatial and temporal resolution. In this work we demonstrate an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond. With 50pT/$\sqrt{Hz}$ sensitivity, we show the first measurements of sensing from mammalian tissue with a diamond sensor using mouse muscle optogenetically activated with blue light. We show these measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques.

preprint2012arXiv

A Numerical Model of Crossed Andreev Reflection and Charge Imbalance

We present a numerical model of local and nonlocal transport properties in a lateral spin valve structure consisting of two magnetic electrodes in contact with a third perpendicular superconducting electrode. By considering the transport paths for a single electron incident at the local F/S interface - in terms of probabilities of crossed or local Andreev reflection, elastic cotunneling or quasiparticle transport - we show that this leads to nonlocal charge imbalance. We compare this model with experimental data from an aluminum-permalloy (Al/Py) lateral spin valve geometry device and demonstrate the effectiveness of this simple approach in replicating experimental behavior.

preprint2012arXiv

Charge Imbalance and Crossed Andreev reflection in Py/Ta Devices

Crossed Andreev reflection in a lateral spin valve geometry device is an aspect of considerable recent interest, particularly with regards to Cooper pair splitting experiments to realize solid state quantum entanglement. In this work, devices are fabricated consisting of two ferromagnetic permalloy (Py) electrodes contacted by a overlaid perpendicular superconducting Ta electrode, of variable lateral in-plane offset within the expected BCS superconducting coherence length $ξ_0$. Experimental electrical transport measurements are presented of local and nonlocal conduction, showing characteristics of non-local or crossed Andreev reflection in the superconducting state at low temperatures in addition to nonlocal effects divergent for T$\rightarrow$T$_c$ attributed to nonlocal charge imbalance.