Source author record

Jacopo Antichi

Jacopo Antichi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2013arXiv

Performances tests on the SPHERE-IFS

Until now, just a few extrasolar planets (~30 out of 860) have been found through the direct imaging method. This number should greatly improve when the next generation of High Contrast Instruments like Gemini Planet Imager (GPI) at Gemini South Telescope or SPHERE at VLT will became operative at the end of this year. In particular, the Integral Field Spectrograph (IFS), one of the SPHERE subsystems, should allow a first characterization of the spectral type of the found extrasolar planets. Here we present the results of the last performance tests that we have done on the IFS instrument at the Institut de Planetologie et d'Astrophysique de Grenoble (IPAG) in condition as similar as possible to the ones that we will find at the telescope. We have found that we should be able to reach contrast down to 5x10$^{-7}$ and make astrometry at sub-mas level with the instrument in the actual conditions. A number of critical issues have been identified. The resolution of these problems could allow to further improve the performance of the instrument.

preprint2012arXiv

MarcoPolo-R narrow angle camera: a three-mirror anastigmat design proposal with a smart finite conjugates refocusing optical system

MarcoPolo-R is a medium-class space mission proposed for the 2015-2025 ESA Cosmic Vision Program with primary goal to return to Earth an unaltered sample from a primitive near-Earth asteroid (NEA). Among the proposed instruments on board, its narrow-angle camera (NAC) should be able to image the candidate object with spatial resolution of 3 mm per pixel at 200 m from its surface. The camera should also be able to support the lander descent operations by imaging the target from several distances in order to locate a suitable place for the landing. Hence a refocusing system is requested to accomplish this task, extending its imaging capabilities. Here we present a three-mirror anastigmat (TMA) common-axis optical design, providing high-quality imaging performances by selecting as entrance pupil the system aperture stop and exploiting the motion of a single mirror inside the instrument to allow the wide image refocusing requested, from infinity up to 200 m above the NEA surface. Such proposal matches with the NAC technical specifications and can be easily implemented with present day technology.

preprint2009arXiv

BIGRE: a low cross-talk integral field unit tailored for extrasolar planets imaging spectroscopy

Integral field spectroscopy (IFS) represents a powerful technique for the detection and characterization of extrasolar planets through high contrast imaging, since it allows to obtain simultaneously a large number of monochromatic images. These can be used to calibrate and then to reduce the impact of speckles, once their chromatic dependence is taken into account. The main concern in designing integral field spectrographs for high contrast imaging is the impact of the diffraction effects and the non-common path aberrations together with an efficient use of the detector pixels. We focus our attention on integral field spectrographs based on lenslet-arrays, discussing the main features of these designs: the conditions of appropriate spatial and spectral sampling of the resulting spectrograph's slit functions and their related cross-talk terms when the system works at the diffraction limit. We present a new scheme for the integral field unit (IFU) based on a dual-lenslet device (BIGRE), that solves some of the problems related to the classical TIGER design when used for such applications. We show that BIGRE provides much lower cross-talk signals than TIGER, allowing a more efficient use of the detector pixels and a considerable saving of the overall cost of a lenslet-based integral field spectrograph.