Researcher profile

J. Ye

J. Ye contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
26works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

26 published item(s)

preprint2026arXiv

Hardware-Economic Manipulation of Dual-Type ${}^{171}$Yb$^+$ Qubits

The dual-type qubit scheme is an emerging method to suppress crosstalk errors in scalable trapped-ion quantum computation and quantum network. Here we report a hardware-economic way to control dual-type $^{171}\mathrm{Yb}^+$ qubits using a single $355\,$nm mode-locked pulsed laser. Utilizing its broad frequency comb structure, we drive the Raman transitions of both qubit types encoded in the $S_{1/2}$ and the $F_{7/2}$ hyperfine levels, and probe their carrier transitions and the motional sidebands. We further demonstrate a direct entangling gate between the two qubit types. Our work can simplify the manipulation of the $^{171}\mathrm{Yb}^+$ qubits both at the hardware and the software level.

preprint2026arXiv

Light Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT

We report on a blinded search for dark matter (DM) using ionization-only (S2-only) signals in XENONnT with a total exposure of $7.83\mathrm{tonne}\times\mathrm{year}$ over 579 days in three science runs. Dedicated background suppression techniques and the first complete S2-only background model in XENONnT provide sensitivity to nuclear recoils of [0.5, 5.0] $\mathrm{keV_\mathrm{nr}}$ and electronic recoils of [0.04, 0.7] $\mathrm{keV_\mathrm{ee}}$. No significant excess over the expected background is observed, and we set 90\% confidence level upper limits on spin-independent DM--nucleon and spin-dependent DM--neutron scattering for DM masses between 3 and 8 $\mathrm{GeV}/c^2$, as well as on DM--electron scattering, axion-like particles, and dark photons, improving on previous constraints. For spin-independent DM--nucleon scattering, we exclude cross sections above $6.0\times10^{-45} $cm$^2$ at a DM mass of 5 $\mathrm{GeV}/c^2$, pushing the XENONnT sensitivity closer to the region where coherent elastic neutrino-nucleus scattering ($\text{CE}ν\text{NS}$) becomes an irreducible background.

preprint2022arXiv

A 20 Gbps PAM4 Data Transmitter ASIC for Particle Physics Experiments

We present the design and test results of a novel data transmitter ASIC operating up to 20.48 Gbps with 4-level Pulse-Amplitude-Modulation (PAM4) for particle physics experiments. This ASIC, named GBS20, is fabricated in a 65 nm CMOS technology. Two serializers share a 5.12 GHz Phase Locked Loop (PLL) clock. The outputs from the serializers are combined into a PAM4 signal that directly drives a Vertical-Cavity-Surface-Emitting-Laser (VCSEL). The input data channels, each at 1.28 Gbps, are scrambled with an internal 27-1 Pseudo-Random Binary Sequence (PRBS), which also serves as a frame aligner. GBS20 is tested to work at 10.24 and 20.48 Gbps with a VCSEL-based Transmitter-Optical-Subassembly (TOSA). The power consumption of GBS20 is below 238 mW and reduced to 164 mW in the low-power mode.

preprint2022arXiv

A 40 Gbps Optical Transceiver for Particle Physics Experiments

We present the design and the test results of a quad-channel optical transceiver module (QTRx) possibly for future particle physics experiments. The transmitters of QTRx, each at 10 Gbps, are based on a Quad-channel VCSEL Diode array Driver (QLDD) and 1 x 4 VCSEL array. The receivers of QTRx, with data rates of 2.56 Gbps or 10 Gbps per channel, are based on a Quad-channel Trans-Impedance and limiting Amplifier (QTIA) and 1 x 4 photodiode array of GaAs or InGaAs. QTRx is 20 mm x 10 mm x 5 mm and couples to an MT fiber connector. Test results indicate that QTRx achieves the design goals with a power consumption of 124 mW per transmitter channel at 10 Gbps and 120 mW at 2.56 Gbps for the receiver channel with an on-chip charge pump. The sensitivities of QTIA are -17 dBm at 2.56 Gbps and -8 dBm at 10 Gbps, respectively. Further improvements with a gold-finger interface and a more compact optical lens are being designed.

preprint2022arXiv

A prototype optical link board with redundancy design for the ATLAS liquid argon calorimeter Phase-2 upgrade

A prototype optical-link board has been developed for the ATLAS Liquid Argon Calorimeter Phase-2 upgrade. The board consists of 24 lpGBT chips and 8 VTRx+ modules and demonstrates the full optical link design of the future front-end board. The board has 22 simplex optical links to transmit detector data, which are emulated in FPGAs and injected through 6 FMC connectors, to the off-detector electronics. The board implements 2 duplex optical links for clocks, control, and monitoring with redundant design to improve the system reliability. Data transmission and all redundant designs have been verified. A fiber routing scheme, in which 2 or 3 VTRx+ modules are re-connected to the front panel with an MPO connector, has been prototyped.

preprint2022arXiv

A radiation tolerant clock generator for the CMS Endcap Timing Layer readout chip

We present the test results of a low jitter Phase Locked Loop (PLL) prototype chip for the CMS Endcap Timing Layer readout chip (ETROC). This chip is based on the improved version of a clock synthesis circuit named ljCDR from the Low-Power Gigabit Transceiver (lpGBT) project. The ljCDR is tested in its PLL mode. An automatic frequency calibration (AFC) block with the Triple Modular Redundancy (TMR) register is developed for the LC-oscillator calibration. The chip was manufactured in a 65 nm CMOS process with 10 metal layers. The chip has been extensively tested, including Total Ionizing Dose (TID) testing up to 300 Mrad and Single Event Upset (SEU) testing with heavy ions possessing a Linear energy transfer (LET) from 1.3 to 62.5 MeV*cm^2/mg.

preprint2022arXiv

Application and modeling of an online distillation method to reduce krypton and argon in XENON1T

A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of $(360 \pm 60)$ ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fit to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove Ar-37 after its injection for a low energy calibration in XENON1T. This makes the usage of Ar-37 as a regular calibration source possible in the future. The online distillation can be applied to next-generation experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large scale detectors.

preprint2022arXiv

Double-Weak Decays of $^{124}$Xe and $^{136}$Xe in the XENON1T and XENONnT Experiments

We present results on the search for double-electron capture ($2ν\text{ECEC}$) of $^{124}$Xe and neutrinoless double-$β$ decay ($0νββ$) of $^{136}$Xe in XENON1T. We consider captures from the K- up to the N-shell in the $2ν\text{ECEC}$ signal model and measure a total half-life of $T_{1/2}^{2ν\text{ECEC}}=(1.1\pm0.2_\text{stat}\pm0.1_\text{sys})\times 10^{22}\;\text{yr}$ with a $0.87\;\text{kg}\times\text{yr}$ isotope exposure. The statistical significance of the signal is $7.0\,σ$. We use XENON1T data with $36.16\;\text{kg}\times\text{yr}$ of $^{136}$Xe exposure to search for $0νββ$. We find no evidence of a signal and set a lower limit on the half-life of $T_{1/2}^{0νββ} > 1.2 \times 10^{24}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$. This is the best result from a dark matter detector without an enriched target to date. We also report projections on the sensitivity of XENONnT to $0νββ$. Assuming a $275\;\text{kg}\times\text{yr}$ $^{136}$Xe exposure, the expected sensitivity is $T_{1/2}^{0νββ} > 2.1 \times 10^{25}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$, corresponding to an effective Majorana mass range of $\langle m_{ββ} \rangle < (0.19 - 0.59)\;\text{eV/c}^2$.

preprint2022arXiv

Exploring the intrinsic energy resolution of liquid scintillator to approximately 1 MeV electrons

We proposed a novel method for exploring the intrinsic energy resolution of a liquid scintillator (LAB + 2.5 g/L PPO + 3 mg/L bis-MSB) for approximately 1 MeV electrons. With the help of coincidence detection technology, single-energy electrons of Bi 207 were effectively selected. With careful measurement and analysis of the energy resolution of a small liquid scintillator detector, the intrinsic energy resolution to 976 keV electrons was extracted to be 1.83%. We used the wide-angle Compton coincidence (WACC) method to measure the luminescent nonlinearity of the liquid scintillator and found that it contributes only weakly to the intrinsic energy resolution of electrons. Such an unexpected large intrinsic energy resolution may come from fluctuations in energy transfer processes.

preprint2022arXiv

Fast (optical) Links

In this write-up we focus on fast data links that read out particle detectors. This includes developments of ASICs, optical modules, identifying passive components such as fiber and connector, and a link system design. A review of the current status is provided. The goal of R\&D is to double (near term) and quadruple (longer term) the present data transmission rate for particle detectors, enabling a wide range of physics exploration and measurements.

preprint2022arXiv

New Horizons: Scalar and Vector Ultralight Dark Matter

The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.

preprint2022arXiv

QTIA, a 2.5 or 10 Gbps 4-Channel Array Optical Receiver ASIC in a 65 nm CMOS Technology

The Quad transimpedance and limiting amplifier (QTIA) is a 4-channel array optical receiver ASIC, developed using a 65 nm CMOS process. It is configurable between the bit rate of 2.56 Gbps and 10 Gbps per channel. QTIA offers careful matching to both GaAs and InGaAs photodiodes. At this R&D stage, each channel has a different biasing scheme to the photodiode for optimal coupling. A charge pump is implemented in one channel to provide a higher reverse bias voltage, which is especially important to mitigate radiation effects on the photodiodes. The circuit functions of QTIA successfully passed the lab tests with GaAs photodiodes.

preprint2022arXiv

The Phase-I Trigger Readout Electronics Upgrade of the ATLAS Liquid Argon Calorimeters

The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Consequently, the background rejection at trigger level is improved through enhanced filtering algorithms utilizing the additional information for topological discrimination of electromagnetic and hadronic shower shapes. This paper presents the final designs of the new electronic elements, their custom electronic devices, the procedures used to validate their proper functioning, and the performance achieved during the commissioning of this system.

preprint2021arXiv

Predicting Future Cognitive Decline with Hyperbolic Stochastic Coding

Hyperbolic geometry has been successfully applied in modeling brain cortical and subcortical surfaces with general topological structures. However such approaches, similar to other surface based brain morphology analysis methods, usually generate high dimensional features. It limits their statistical power in cognitive decline prediction research, especially in datasets with limited subject numbers. To address the above limitation, we propose a novel framework termed as hyperbolic stochastic coding (HSC). Our preliminary experimental results show that our algorithm achieves superior results on various classification tasks. Our work may enrich surface based brain imaging research tools and potentially result in a diagnostic and prognostic indicator to be useful in individualized treatment strategies.

preprint2020arXiv

$^{222}$Rn emanation measurements for the XENON1T experiment

The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the $^{222}$Rn emanation measurements performed for the XENON1T dark matter experiment. Together with the bulk impurity screening campaign, the results enabled us to select the radio-purest construction materials, targeting a $^{222}$Rn activity concentration of 10 $μ$Bq/kg in 3.2 t of xenon. The knowledge of the distribution of the $^{222}$Rn sources allowed us to selectively eliminate critical components in the course of the experiment. The predictions from the emanation measurements were compared to data of the $^{222}$Rn activity concentration in XENON1T. The final $^{222}$Rn activity concentration of (4.5 $\pm$ 0.1) $μ$Bq/kg in the target of XENON1T is the lowest ever achieved in a xenon dark matter experiment.

preprint2020arXiv

A 4-Channel 10-Gbps/ch CMOS VCSEL Array Driver with on-chip Charge-pumps

We present the design and test results of a 4-channel 10-Gbps/ch Vertical-Cavity Surface-Emitting Laser array driver, the cpVLAD. With on-chip charge-pumps to extend the biasing headroom for the VCSELs needed for low temperature operation and mitigation of the radiation effects. The cpVLAD was fabricated in a 65-nm CMOS technology. The test results show that the cpVLAD is capable of driving VCSELs with forward bias voltages as high as 2.8 V from a 2.5 V power supply. The power consumption of the cpVLAD is 94 mW/ch.

preprint2020arXiv

A gigabit transceiver for the ATLAS inner tracker pixel detector readout upgrade

This paper presents the design and simulation results of a gigabit transceiver Application Specific Integrated Circuit (ASIC) called GBCR for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR has four upstream receiver channels and a downstream transmitter channel. Each upstream channel operates at 5.12 Gbps, while the downstream channel operates at 2.56 Gbps. In each upstream channel, GBCR equalizes a signal received through a 5-meter 34-American Wire Gauge (AWG) twin-axial cable, retimes the data with a recovered clock, and drives an optical transmitter. In the downstream channel, GBCR receives the data from an optical receiver and drives the same type of cable as the upstream channels. The output jitter of an upstream channel is 26.5 ps and the jitter of the downstream channel after the cable is 33.5 ps. Each upstream channel consumes 78 mW and each downstream channel consumes 27 mW. Simulation results of the upstream test channel suggest that a significant jitter reduction could be achieved with minimally increased power consumption by using a Feed Forward Equalizer (FFE) + Decision Feedback Equalization (DFE) in addition to the linear equalization of the baseline channel. GBCR is designed in a 65-nm CMOS technology.

preprint2020arXiv

A novel quad-channel 10 Gbps CMOS VCSEL array driver with integrated charge pumps

We present a novel design and the test results of a 4-channel driver for an array of Vertical-Cavity Surface-Emitting Lasers (VCSELs). This ASIC, named cpVLAD and fabricated in a 65 nm CMOS technology, has on-chip charge pumps and is for data rates up to 10 Gbps per channel. The charge pumps are implemented to address the issue of voltage margin of the VCSEL driving stage in the applications under low temperature and harsh radiation environment. Test results indicate that cpVLAD is capable of driving VCSELs with forward voltages of up to 2.8 V using 1.2 V and 2.5 V power supplies with a power consumption of 94 mW/channel.

preprint2020arXiv

A TOSA/ROSA-Based Optical Transmitter (MTx+)/Transceiver (MTRx+) for High-Energy Physics Experiments

We present a dual-channel optical transmitter (MTx+)/transceiver (MTRx+) for the front-end readout electronics of high-energy physics experiments. MTx+ utilizes two Transmitter Optical Sub-Assemblies (TOSAs) and MTRx+ utilizes a TOSA and a Receiver Optical Sub-Assemblies (ROSA). Both MTx+ and MTRx+ receive multimode fibers with standard Lucent Connectors (LCs) as the optical interface and can be panel or board mounted to a motherboard with a standard Enhanced Small Form-factor Pluggable (SFP+) connector as the electrical interface. MTx+ and MTRx+ employ a dual-channel Vertical-Cavity Surface-Emitting Laser (VCSEL) driver ASIC called LOCld65, which brings the transmitting data rate up to 14 Gbps per channel. MTx+ and MTRx+ have been tested to survive 4.9 kGy(SiO2).

preprint2020arXiv

Characterization of a gigabit transceiver for the ATLAS inner tracker pixel detector readout upgrade

We present a gigabit transceiver prototype Application Specific Integrated Circuit (ASIC), GBCR, for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR is designed in a 65-nm CMOS technology and consists of four upstream receiver channels, a downstream transmitter channel, and an Inter-Integrated Circuit (I2C) slave. The upstream channels receive the data at 5.12 Gbps passing through 5-meter 34-American Wire Gauge (AWG) Twin-axial (Twinax) cables, equalize them, retime them with a recovered clock, and then drive an optical transmitter. The downstream channel receives the data at 2.56 Gbps from an optical receiver and drives the cable as same as the upstream channels. The jitter of the upstream channel output is measured to be 35 ps (peak-peak) when the Clock-Data Recovery (CDR) module is turned on and the jitter of the downstream channel output after the cable is 138 ps (peak-peak). The power consumption of each upstream channel is 72 mW when the CDR module is turned on and the downstream channel consumes 27 mW. GBCR survives the total ionizing dose of 200 kGy.

preprint2020arXiv

Design and hardware evaluation of the optical-link system for the ATLAS Liquid Argon Calorimeter Phase-II Upgrade

An optical link system is being developed for the ATLAS Liquid Argon Calorimeter Phase-II upgrade. The optical link system is responsible for transmit the data of over 182 thousand detector channels from 1524 Front-End Boards (FEBs) through 26 optical fibers per FEB over 150 meters to the counting room and brings clocks, bunch crossing reset signals and slow control/monitoring signals back to the FEBs. The optical link system is based on the Low-Power GigaBit Transceivers (lpGBTs) and the Versatile optical Transceiver (VTRx+) modules, which both are being developed for the High-Luminosity LHC upgrade. An evaluation board is designed and the major functions of the optical link system are being evaluated. The design of the optical link system and the evaluation of major functions are presented in the paper.

preprint2020arXiv

Energy resolution and linearity of XENON1T in the MeV energy range

Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 $σ/μ$ is as low as (0.80$\pm$0.02) % in its one-ton fiducial mass, and for single-site interactions at $Q_{ββ}$. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.

preprint2020arXiv

LBECA: A Low Background Electron Counting Apparatus for Sub-GeV Dark Matter Detection

Two-phase noble liquid detectors, with large target masses and effective background reduction, are currently leading the dark matter direct detection for WIMP masses above a few GeV. Due to their sensitivity to single ionized electron signals, these detectors were shown to also have strong constraints for sub-GeV dark matter via their scattering on electrons. In fact, the most stringent direct detection constraints for sub-GeV dark matter down to as low as ~5 MeV come from noble liquid detectors, namely XENON10, DarkSide-50, XENON100 and XENON1T, although these experiments still suffer from high background at single or a few electron level. LBECA is a planned 100-kg scale liquid xenon detector with significant reduction of the single and a few electron background. The experiment will improve the sensitivity to sub-GeV dark matter by three orders of magnitude compared to the current best constraints.

preprint2020arXiv

Prototyping of a 25 Gbps optical transmitter for applications in high-energy physics experiments

Development of optical links with 850 nm multi-mode vertical-cavity surface-emitting lasers (VCSELs) has advanced to 25 Gbps in speed. For applications in high-energy experiments, the transceivers are required to be tolerant in radiation and particle fields. We report on prototyping of a miniature transmitter named MTx+, which is developed for high speed transmission with the dual-channel laser driver LOCld65 and 850 nm VCSELs packaged in TOSA format. The LOCld65 is fabricated in the TSMC 65 nm process and is packaged in the QFN-40 for assembly. The MTx+ modules and test kits were first made with PCB and components qualified for 10 Gbps applications, and were tested for achieving 14 Gbps. The data transfer rate of the MTx+ module is investigated further for the speed of up to 25 Gbps. The LOCld65 is examined with post-layout simulation and the module design upgraded with components including the TOSA qualified for 25 Gbps applications. The PCB material is replaced by the Panasonic MEGTRON6. The revised MTx+ is tested at 25 Gbps and the eye-diagram shows a mask margin of 22 %.

preprint2020arXiv

Search for Light Dark Matter Interactions Enhanced by the Migdal effect or Bremsstrahlung in XENON1T

Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above $\sim$ 5 GeV/c$^2$, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, which leads to the excitation and ionization of the recoiling atom (the Migdal effect) or the emission of a Bremsstrahlung photon. In this letter, we report on a probe of low-mass dark matter with masses down to about 85 MeV/c$^2$ by looking for electronic recoils induced by the Migdal effect and Bremsstrahlung, using data from the XENON1T experiment. Besides the approach of detecting both scintillation and ionization signals, we exploit an approach that uses ionization signals only, which allows for a lower detection threshold. This analysis significantly enhances the sensitivity of XENON1T to light dark matter previously beyond its reach.