Researcher profile

J. Schultes

J. Schultes contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - Baseline
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2023arXiv

The new APD-Based Readout of the Crystal Barrel Calorimeter -- An Overview

The Crystal Barrel is an electromagnetic calorimeter consisting of 1380 CsI(Tl) scintillators, and is currently installed at the CBELSA/TAPS experiment where it is used to detect decay products from photoproduction of mesons. The readout of the Crystal Barrel has been upgraded in order to integrate the detector into the first level of the trigger and to increase its sensitivity for neutral final states. The new readout uses avalanche photodiodes in the front-end and a dual back-end with branches optimized for energy and time measurement, respectively. An FPGA-based cluster finder processes the whole hit pattern within less than 100 ns. The important downside of APDs -- the temperature dependence of their gain -- is handled with a temperature stabilization and a compensating bias voltage supply. Additionally, a light pulser system allows the APDs' gains to be measured during beamtimes.

preprint2021arXiv

Observation of a structure in the M$_{pη}$ invariant mass distribution near 1700 MeV/$c^2$ in the $\mathbf{γp \rightarrow p π^0 η} $ reaction

The reaction $γp \rightarrow p π^0 η$ has been studied with the CBELSA/TAPS detector at the electron stretcher accelerator ELSA in Bonn for incident photon energies from threshold up to 3.1 GeV. This paper has been motivated by the recently claimed observation of a narrow structure in the M$_{Nη}$ invariant mass distribution at a mass of 1678 MeV/$c^2$. The existence of this structure cannot be confirmed in the present work. Instead, for E$_γ$ = 1400 - 1500 MeV and the cut M$_{pπ^0} \le 1190 $ MeV/$c^2$ a statistically significant structure in the M$_{pη}$ invariant mass distribution near 1700 MeV/$c^2$ is observed with a width of $Γ\approx 35$ MeV/$c^2$ while the mass resolution is $σ_{res}$ = 5 MeV/$c^2$. Increasing the incident photon energy from 1420 to 1540 MeV this structure shifts in mass from $\approx$ 1700MeV/c$^2$ to $\approx$ 1725 MeV/$c^2$; the width increases to about 50 MeV/$c^2$ and decreases thereafter. The cross section associated with this structure reaches a maximum of $\approx$ 100 nb around E$_γ \approx$ 1490 MeV (W $\approx $ 1920 MeV), which coincides with the $p a_0$ threshold. Three scenarios are discussed which might be the origin of this structure in the M$_{pη}$ invariant mass distribution. The most likely interpretation is that it is due to a triangular singularity in the $γp \rightarrow p a_0 \rightarrow p π^0 η$ reaction

preprint2011arXiv

A Layer Correlation technique for pion energy calibration at the 2004 ATLAS Combined Beam Test

A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in front of and between the calorimeters of the ATLAS experiment were calculated with simulated Geant4 Monte Carlo events and used to reconstruct the energy of pions impinging on the calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies between 20 GeV and 180 GeV, the particle energy is reconstructed within 3% and the energy resolution is improved by between 11% and 25% compared to the resolution at the electromagnetic scale.

preprint2008arXiv

Alignment of the Pixel and SCT Modules for the 2004 ATLAS Combined Test Beam

A small set of final prototypes of the ATLAS Inner Detector silicon tracker (Pixel and SCT) were used to take data during the 2004 Combined Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons and photons) with a momentum range of 2 to 180 GeV/c. Four independent methods were used to align the silicon modules. The corrections obtained were validated using the known momenta of the beam particles and were shown to yield consistent results among the different alignment approaches. From the residual distributions, it is concluded that the precision attained in the alignment of the silicon modules is of the order of 5 micrometers in their most precise coordinate.