Researcher profile

J. Lindner

J. Lindner contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Direct imaging of the ac component of the pumped spin polarization with element specificity

Spin pumping in a ferromagnet/nonferromagnet heterostructure is directly imaged with spatial resolution as well as element selectivity. The time-resolved detection in scanning transmission x-ray microscopy allows to directly probe the spatial extent of the ac spin polarization in Co-doped ZnO which is generated by spin pumping from an adjacent permalloy microstrip. Comparing the relative phases of the dynamic magnetization component of the two constituents is possible and found to be antiphase. The correlation between the distribution of the magnetic excitation in the permalloy and the Co-doped ZnO reveals that laterally there is no one-to-one correlation. The observed distribution is rather complex, but integrating over larger areas clearly demonstrates that the spin polarization in the nonferromagnet extends laterally beyond the region of the ferromagnetic microstrip. Therefore the observations are better explained by a local spin pumping efficieny and a lateral propagation of the ac spin polarization in the nonferromagnet over the range of a few micrometers.

preprint2020arXiv

Magnetization dynamics in synthetic antiferromagnets: Role of dynamical energy and mutual spin pumping

We investigate magnetization dynamics in asymmetric interlayer exchange coupled Py/Ru/Py trilayers using both vector network analyzer-based and electrically detected ferromagnetic resonance techniques. Two different ferromagnetic resonance modes, in-phase and out-of-phase, are observed across all three regimes of the static magnetization configurations, through antiparallel alignment at low fields, the spin-flop transition at intermediate fields, and parallel alignment at high fields. The nonmonotonic behavior of the modes as a function of the external field is explained in detail by analyzing the interlayer exchange and Zeeman energies and is found to be solely governed by the interplay of their dynamical components. In addition, the linewidths of both modes were determined across the three regimes and the different behaviors of the linewidths versus external magnetic field are attributed to mutual spin pumping induced in the samples. Interestingly, the difference between the linewidths of the out-of-phase and in-phase modes decreases at the spin-flop transition and is reversed between the antiparallel and parallel aligned magnetization states.

preprint2020arXiv

The HEV Ventilator

HEV is a low-cost, versatile, high-quality ventilator, which has been designed in response to the COVID-19 pandemic. The ventilator is intended to be used both in and out of hospital intensive care units, and for both invasive and non-invasive ventilation. The hardware can be complemented with an external turbine for use in regions where compressed air supplies are not reliably available. The standard modes provided include PC-A/C(Pressure Assist Control),PC-A/C-PRVC(Pressure Regulated Volume Control), PC-PSV (Pressure Support Ventilation) and CPAP (Continuous Positive airway pressure). HEV is designed to support remote training and post market surveillance via a web interface and data logging to complement the standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the quality of the pressure curves and the reactivity of the trigger, delivering a global performance which will be applicable to ventilator needs beyond theCOVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with their performance evaluation.

preprint2020arXiv

The HEV Ventilator Proposal

We propose the design of a ventilator which can be easily manufactured and integrated into the hospital environment to support COVID-19 patients. The unit is designed to support standard ventilator modes of operation, most importantly PRVC (Pressure Regulated Volume Control) and SIMV-PC (Synchronised Intermittent Mandatory Ventilation) modes. The unit is not yet an approved medical device and is in the concept and prototyping stage. It is presented here to invite fast feedback for development and deployment in the face of the COVID-19 pandemic.