Source author record

J. Lee Grenfell

J. Lee Grenfell appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2012arXiv

Atmospheric constraints for the CO2 partial pressure on terrestrial planets near the outer edge of the habitable zone

In recent years, several potentially habitable, probably terrestrial exoplanets and exoplanet candidates have been discovered. The amount of CO2 in their atmosphere is of great importance for surface conditions and habitability. In the absence of detailed information on the geochemistry of the planet, this amount could be considered as a free parameter. Up to now, CO2 partial pressures for terrestrial planets have been obtained assuming an available volatile reservoir and outgassing scenarios. This study aims at calculating the allowed maximum CO2 pressure at the surface of terrestrial exoplanets orbiting near the outer boundary of the habitable zone by coupling the radiative effects of the CO2 and its condensation at the surface. These constraints might limit the permitted amount of atmospheric CO2, independent of the planetary reservoir. A 1D radiative-convective cloud-free atmospheric model was used. CO2 partial pressures are fixed according to surface temperature and vapor pressure curve. Considered scenarios cover a wide range of parameters. Results show that for planets in the habitable zone around K-, G-, and F-type stars the allowed CO2 pressure is limited by the vapor pressure curve and not by the planetary reservoir. The maximum CO2 pressure lies below the CO2 vapor pressure at the critical point of pcrit =73.8 bar. For M-type stars, CO2 pressures above pcrit are possible for almost all scenarios considered across the habitable zone. This implies that determining CO2 partial pressures for terrestrial planets by using only geological models is probably too simplified and might over-estimate atmospheric CO2 towards the outer edge of the habitable zone. (abridged)

preprint2011arXiv

Spectroscopic characterization of the atmospheres of potentially habitable planets: GL 581 d as a model case study

(abridged) The Super-Earth candidate GL 581 d is the first potentially habitable extrasolar planet. Therefore, GL 581 d is used to illustrate a hypothetical detailed spectroscopic characterization of such planets. Atmospheric profiles from 1D radiative-convective model scenarios of GL 581 d were used to calculate high-resolution synthetic spectra. From the spectra, signal-to-noise ratios were calculated for a telescope such as the planned James Webb Space Telescope. The presence of the model atmospheres could be clearly inferred from the calculated synthetic spectra due to strong water and carbon dioxide absorption bands. Surface temperatures could be inferred for model scenarios with optically thin spectral windows. Dense, CO2-rich scenarios did not allow for the characterization of surface temperatures and to assess habitability. Degeneracies between CO2 concentration and surface pressure further complicated the interpretation of the calculated spectra, hence the determination of atmospheric conditions. Still, inferring approximative CO2 concentrations and surface pressures would be possible. In practice, detecting atmospheric signals is challenging. The SNR for a single transit was only larger than unity in some near-IR bands for transmission spectroscopy. Most interestingly, the false-positive detection of biomarker candidates such as methane and ozone could be possible in low resolution spectra due to the presence of CO2 absorption bands which overlap with biomarker spectral bands. This can be avoided however by observing all main CO2 IR bands instead of concentrating on, e.g., the 4.3 or 15 micron bands only. Furthermore, a masking of ozone signatures by CO2 absorption bands is shown to be possible. Simulations imply that such a false-negative detection of ozone would be possible even for rather large ozone concentrations of up to 1E-5.