Researcher profile

J. Kotoku

J. Kotoku contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2006arXiv

Discovery of a New X-Ray Burst/Millisecond Accreting Pulsar HETE J1900.1-2455

A class of low-mass X-ray binary sources are known to be both X-ray burst sources and millisecond pulsars at the same time. A new source of this class was discovered by High Energy Transient Explorer 2 (HETE-2) on 14 June 2005 as a source of type-I X-ray bursts, which was named HETE J1900.1-2455. Five X-ray bursts from HETE J1900.1-2455 were observed during the summer of 2005. The time resolved spectral analysis of these bursts have revealed that their spectra are consistent with the blackbody radiation throughout the bursts. The bursts show the indication of radius expansion. The bolometric flux remains almost constant during the photospheric radius expansion while blackbody temperature dropped during the same period. Assuming that the flux reached to the Eddington limit on a standard 1.4 solar mass neutron star with a helium atmosphere, we estimate the distance to the source to be $\sim$ 4 kpc.

preprint2006arXiv

Hard X-ray Detector (HXD) on Board Suzaku

The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for the phoswich counter. Tight active shielding of the HXD results in a large array of guard counters surrounding the main detector parts. These anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large effective area for sub-MeV to MeV gamma-rays. They work as an excellent gamma-ray burst monitor with limited angular resolution (~5 degree). The on-board signal-processing system and the data transmitted to the ground are also described.