Researcher profile

J. H. Liu

J. H. Liu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

High thermoelectric performance of half-Heusler compound BiBaK with intrinsically low lattice thermal conductivity

Half-Heusler compounds usually exhibit relatively higher lattice thermal conductivity that is undesirable for thermoelectric applications. Here we demonstrate by first-principles calculations and Boltzmann transport theory that the BiBaK system is an exception, which has rather low thermal conductivity as evidenced by very small phonon group velocity and relaxation time. Detailed analysis indicates that the heavy Bi and Ba atoms form a cage-like structure, inside which the light K atom rattles with larger atomic displacement parameters. In combination with its good electronic transport properties, the BiBaK shows a maximum n-type ZT value of 1.9 at 900 K, which outperforms most half-Heusler thermoelectric materials.

preprint2019arXiv

Improving the resolving power of Isochronous Mass Spectrometry by employing an in-ring mechanical slit

Isochronous Mass Spectrometry (IMS) in heavy-ion storage rings is an excellent experimental method for precision mass measurements of exotic nuclei. In the IMS, the storage ring is tuned in a special isochronous ion-optical mode. Thus, the mass-over-charge ratios of the stored ions are directly reflected by their respective revolution times in first order. However, the inevitable momentum spread of secondary ions increases the peak widths in the measured spectra and consequently limits the achieved mass precision. In order to achieve a higher mass resolving power, the ring aperture was reduced to 60 mm by applying a mechanical slit system at the dispersive straight section. The momentum acceptance was reduced as well as better isochronous conditions were achieved. The results showed a significant improvement of the mass resolving power reaching $5.2 \times 10^{5}$, though at the cost of about 40\% ion loss.