Researcher profile

J. Glenn

J. Glenn contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Full-Array Noise Performance of Deployment-Grade SuperSpec mm-wave On-Chip Spectrometers

SuperSpec is an on-chip filter-bank spectrometer designed for wideband moderate-resolution spectroscopy at millimeter wavelengths, employing TiN kinetic inductance detectors. SuperSpec technology will enable large-format spectroscopic integral field units suitable for high-redshift line intensity mapping and multi-object spectrographs. In previous results we have demonstrated noise performance in individual detectors suitable for photon noise limited ground-based observations at excellent mm-wave sites. In these proceedings we present the noise performance of a full $R\sim 275$ spectrometer measured using deployment-ready RF hardware and software. We report typical noise equivalent powers through the full device of $\sim 3 \times 10^{-16} \ \mathrm{W}/\sqrt{\mathrm{Hz}}$ at expected sky loadings, which are photon noise dominated. Based on these results, we plan to deploy a six-spectrometer demonstration instrument to the Large Millimeter Telescope in early 2020.

preprint2009arXiv

Studies of Millimeter-Wave Atmospheric Noise Above Mauna Kea

We report measurements of the fluctuations in atmospheric emission (atmospheric noise) above Mauna Kea recorded with Bolocam at 143 and 268 GHz from the Caltech Submillimeter Observatory (CSO). The 143 GHz data were collected during a 40 night observing run in late 2003, and the 268 GHz observations were made in early 2004 and early 2005 over a total of 60 nights. Below 0.5 Hz, the data time-streams are dominated by atmospheric noise in all observing conditions. The atmospheric noise data are consistent with a Kolmogorov-Taylor (K-T) turbulence model for a thin wind-driven screen, and the median amplitude of the fluctuations is 280 mK^2 rad^(-5/3) at 143 GHz and 4000 mK^2 rad^(-5/3) at 268 GHz. Comparing our results with previous ACBAR data, we find that the normalization of the power spectrum of the atmospheric noise fluctuations is a factor of 80 larger above Mauna Kea than above the South Pole at millimeter wavelengths. Most of this difference is due to the fact that the atmosphere above the South Pole is much drier than the atmosphere above Mauna Kea. However, the atmosphere above the South Pole is slightly more stable as well: the fractional fluctuations in the column depth of precipitable water vapor are a factor of sqrt(2) smaller at the South Pole compared to Mauna Kea. Based on our atmospheric modeling, we developed several algorithms to remove the atmospheric noise, and the best results were achieved when we described the fluctuations using a low-order polynomial in detector position over the 8 arcmin field of view (FOV). However, even with these algorithms, we were not able to reach photon-background-limited instrument photometer (BLIP) performance at frequencies below 0.5 Hz in any observing conditions.