Researcher profile

J. Dey

J. Dey contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

An Upgrade Path for the Fermilab Accelerator Complex

The completion of the PIP-II project and its superconducting linear accelerator will provide up to 1.2 MW of beam power to the LBNF/DUNE facility for neutrino physics. It will also be able to produce high-power beams directly from the linac that can be used for lower-energy particle physics experiments as well, such as directing beam toward the Muon Campus at Fermilab for example. Any further significant upgrade of the beam power to DUNE, however, will be impeded by the limitations of the present Booster synchrotron at the facility. To increase the power to DUNE by a factor of two would require a new accelerator arrangement to feed the Main Injector that does not include the Booster. In what follows, a path toward upgrading the Fermilab accelerator complex to bring the beam power for DUNE to 2.4 MW is presented, using a new rapid-cycling synchrotron plus an energy upgrade to the PIP-II linac. The path includes the ability to instigate a new lower-energy, very high-power beam delivery system for experiments that can address much of the science program presented by the Booster Replacement Science Working Group. It also allows for the future possibility to go beyond 2.4 MW up to roughly 4 MW from the Main Injector.

preprint2022arXiv

Scintillation Event Localization in Hemi-Ellipsoid Detector for SPECT, a simulation study using Geant4 Monte-Carlo

A high sensitivity Cardiac SPECT system using curved crystals with pinhole collimation was proposed previously (Dey, IEEE TNS 2012, Bhusal et al, Med. Phys. 2019). Here, we hypothesize that a high curvature hemi-ellipsoid detector results in measurable differences in light distribution from events at different depths in the crystal. This was tested by analyzing the scintillation light in hemi-ellipsoid detector using Monte-Carlo (Geant4) and evaluation of both the localization error at detector and the back-projected errors in object-space. We used Geant4 to simulate the propagation of scintillation light in a monolithic hemi-ellipsoidal CsI crystal. A look-up table (LUT) was created to map the points inside the crystal to the expected light pattern on the crystal surface using Geant4. In thirteen zones across the crystal, gamma-rays were simulated and the resulting scintillator light intensity on the surface was captured, serving as our experimental interactions. A Poisson-statistics-based algorithm was developed to limit the search of the gamma-ray event locations into small regions of the LUT and fine-tuned by interpolating between selected LUT points by comparing the light distribution of the gamma interactions and LUT light patterns. The localized events were individually back-projected to the object mid-plane, and the errors recorded. Excluding some outliers (up to 2%), the localized errors averaged over all the zones was 0.71 (+/-0.44) mm with a worse case of 1.36 (+/-0.67) mm at the apex. When back-projected to the midplane of the object for Cardiac SPECT, the errors were <1mm and average error was 0.4(+/-0.22) mm, due to the high system magnification afforded by the detector. Thus, for our high sensitivity system, we were also able to achieve high resolution, assuming perfect pinhole collimator resolution recovery for Cardiac SPECT application.