Researcher profile

J. Alonso

J. Alonso contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
9works
0followers
10topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

MATISSE, the VLTI mid-infrared imaging spectro-interferometer

Context:Optical interferometry is at a key development stage. ESO's VLTI has established a stable, robust infrastructure for long-baseline interferometry for general astronomical observers. The present second-generation instruments offer a wide wavelength coverage and improved performance. Their sensitivity and measurement accuracy lead to data and images of high reliability. Aims:We have developed MATISSE, the Multi AperTure mid-Infrared SpectroScopic Experiment, to access high resolution imaging in a wide spectral domain and explore topics such: stellar activity and mass loss; planet formation and evolution in the gas and dust disks around young stars; accretion processes around super massive black holes in AGN. Methods:The instrument is a spectro-interferometric imager covering three atmospheric bands (L,M,N) from 2.8 to 13.0 mu, combining four optical beams from the VLTI's telscopes. Its concept, related observing procedure, data reduction and calibration approach are the product of 30 years of instrumental research. The instrument utilizes a multi-axial beam combination that delivers spectrally dispersed fringes. The signal provides the following quantities at several spectral resolutions: photometric flux, coherent fluxes, visibilities, closure phases, wavelength differential visibilities and phases, and aperture-synthesis imaging. Results:We provide an overview of the physical principle of the instrument and its functionalities, the characteristics of the delivered signal, a description of the observing modes and of their performance limits. An ensemble of data and reconstructed images are illustrating the first acquired key observations. Conclusion:The instrument has been in operation at Cerro Paranal, ESO, Chile since 2018, and has been open for science use by the international community since April 2019. The first scientific results are being published now.

preprint2022arXiv

Neutrino Physics Opportunities with the IsoDAR Source at Yemilab

IsoDAR seeks to place a high-power-cyclotron and target combination, as an intense source of $\barν_e$ at the level of $\sim 10^{23}$/year, close to a kiloton-scale neutrino detector in order to gain sensitivity to very short-baseline neutrino oscillations ($\barν_e \rightarrow \barν_{e}$) and perform precision tests of the weak interaction, among other physics opportunities. Recently, IsoDAR has received preliminary approval to be paired with the 2.26~kton target volume liquid scintillator detector at the Yemi Underground Laboratory (Yemilab) in Korea, at a 17~m center-to-center baseline, and cavern excavation for IsoDAR is now complete. In this paper, we present the physics capabilities of IsoDAR@Yemilab in terms of sensitivity to oscillations (via inverse beta decay, IBD; $\barν_e+p \rightarrow e^+ + n$), including initial-state wavepacket effects, and the weak mixing angle (via elastic scattering off atomic electrons, $\barν_e + e^- \rightarrow \barν_e + e^-$). We also introduce a study of IsoDAR sensitivity to new particles, such as a light $X$ boson, produced in the target that decays to $ν_e \bar ν_e$.

preprint2022arXiv

On the geometry of positive cones in finitely generated groups

We study the geometry of positive cones of left-invariant total orders (left-order, for short) in finitely generated groups. We introduce the \textit{Hucha property} and the \texit{Prieto property} for left-orderable groups. The first one means that in any left-order the corresponding positive cone is not coarsely connected, and the second one that in any left-order the corresponding positive cone is coarsely connected. We show that all left-orderable free products have the Hucha property, and that the Hucha property is stable under certain free products with amalgamatation over Prieto subgroups. As an application we show that non-abelian limit groups in the sense of Z. Sela (e.g. free groups, fundamental group of hyperbolic surfaces, doubles of free groups and others) and non-abelian finitely generated subgroups of free $\mathbb{Q}$-groups in the sense of G. Baumslag have the Hucha property. In particular, this implies that these groups have empty BNS-invariant $Σ^1$ and that they don't have finitely generated positive cones.

preprint2022arXiv

Slice-selective Zero Echo Time imaging of ultra-short T2 tissues based on spin-locking

Purpose: To expand the capabilities of Zero Echo Time (ZTE) pulse sequences with a slice selection method suitable for the shortest-lived tissues in the body. Methods: We introduce two new sequences that integrate spin-locking pulses into standard ZTE imaging to achieve slice selection: one for moderately short $T_2$ (DiSLoP), the other for ultra-short $T_2$ samples (PreSLoP). These methods exploit the slower signal decay (at $T_{1ρ}\gg T_2$) to retain the magnetization in the slices during the selection process, which is otherwise comparable to or even much longer than $T_2$. Results: We demonstrate control over the slice profiles and positions for 2D imaging. We measure magnetization decay times during spin-locking ($T_{1ρ}$) as a function of pulse amplitude, showing significant lifetime enhancement for amplitudes as low as 10 uT. We show imaging of slice-selected samples with $T_2$ characteristic times in the range of single milliseconds with DiSLoP and PreSLoP, and with the latter for sub-millisecond $T_2$ tissues. As compared to standard 3D ZTE sequences, PreSLoP achieves the same signal-to-noise ratio (SNR) in 2-5 times shorter scan times, and we argue that this is due to the filling scheme of the finite gap at the center of $k$-space unavoidable with ZTE sequences. Finally, we discuss a combination of DiSLoP with a dynamical decoupling sequence to avoid this central gap, leading to further scan time accelerations. Conclusions: The proposed sequences are capable of slice-selected 2D imaging of tissues with $T_2$ as low as 275 us with good SNR within clinically acceptable scan times.

preprint2021arXiv

A Fast 0.5T Prepolarizer Module for Preclinical Magnetic Resonance Imaging

We present a magnet and high power electronics for Prepolarized Magnetic Resonance Imaging (PMRI) in a home-made, special-purpose preclinical system designed for simultaneous visualization of hard and soft biological tissues. PMRI boosts the signal-to-noise ratio (SNR) by means of a long and strong magnetic pulse which must be rapidly switched off prior to the imaging pulse sequence, in timescales shorter than the spin relaxation (or T1) time of the sample. We have operated the prepolarizer at up to 0.5 T and demonstrated enhanced magnetization, image SNR and tissue contrast with PMRI of tap water, an ex vivo mouse brain and food samples. These have T1 times ranging from hundreds of milli-seconds to single seconds, while the preliminary high-power electronics setup employed in this work can switch off the prepolarization field in tens of milli-seconds. In order to make this system suitable for solid-state matter and hard tissues, which feature T1 times as short as 10 ms, we are developing new electronics which can cut switching times to ~300 us. This does not require changes in the prepolarizer module, opening the door to the first experimental demonstration of PMRI on hard biological tissues.

preprint2021arXiv

Prepolarized MRI of Hard Tissues and Solid-State Matter

Prepolarized Magnetic Resonance Imaging (PMRI) is a long-established technique conceived to counteract the loss in signal-to-noise ratio (SNR) inherent to low-field MRI systems. When it comes to hard biological tissues and solid-state matter, PMRI is severely restricted by their ultra-short characteristic relaxation times. Here we demonstrate that efficient hard tissue prepolarization is within reach with a special-purpose 0.26 T scanner designed for dental MRI and equipped with suitable high-power electronics. We have characterized the performance of a 0.5 T prepolarizer module which can be switched on and off in just 200 us. To that end, we have used resin, dental and bone samples, all with T1 times in the order of 20 ms at our field strength. The measured SNR enhancement is in good agreement with a simple theoretical model, and small deviations in extreme regimes can be attributed to mechanical vibrations due to the magnetic interaction between the prepolarization and main magnets. Finally, we argue that these results can be applied to clinical dental imaging, opening the door to replacing hazardous X-ray systems with low-field PMRI scanners.

preprint2020arXiv

Peripheral Nerve Stimulation limits with fast narrow and broad-band pulses

Peripheral Nerve Stimulation (PNS) constrains the clinical performance of Magnetic Resonance and Particle Imaging (MRI and MPI) systems. Extensive magneto-stimulation studies have been carried out recently in the field of MPI, where typical operation frequencies range from single to tens of kilo-hertz. PNS literature is scarce for MRI in this regime, where the resonant character of MPI coils prevents studies of broad-band excitation pulses. We have constructed an apparatus for PNS threshold determination on a subject's limb, capable of narrow and broad-band magnetic excitation with pulse characteristic times down to 40 us. From a first set of measurements on 51 volunteers, we observe that PNS limits coincide for sinusoidal (biphasic narrow-band) and triangular (biphasic broad-band) excitations, and are slightly lower for trapezoidal (monophasic broad-band) pulses. We have also measured statistically significant correlations of PNS sensitivity with arm size and body weight, and no correlation with height or gender. As opposed to resonant systems, our setup allows the execution of arbitrarily short pulse trains. We have confirmed thresholds increase significantly as trains transition from tens to a few pulses also in these fast timescales. By changing the polarity of the coils in our setup, we also looked at the influence of the spatial distribution of magnetic field strength on PNS effects. We find that thresholds are higher in an approximately linearly inhomogeneous field (relevant to MRI) than in a rather homogeneous distribution (as in MPI). Finally, given the large intersubject variability of PNS sensitivity, we propose employing a versatile low-cost system (such as presented here) for fast offline determination of a subject's limits prior to medical scanning, and then using this information to boost clinical imaging while preserving the patient's safety.

preprint2020arXiv

Simultaneous imaging of hard and soft biological tissues in a low-field dental MRI scanner

Magnetic Resonance Imaging (MRI) of hard biological tissues is challenging due to the fleeting lifetime and low strength of their response to resonant stimuli, especially at low magnetic fields. Consequently, the impact of MRI on some medical applications, such as dentistry, continues to be limited. Here, we present three-dimensional reconstructions of ex-vivo human teeth, as well as a rabbit head and part of a cow femur, all obtained at a field strength of only 260 mT. These images are the first featuring soft and hard tissues simultaneously at sub-Tesla fields, and they have been acquired in a home-made, special-purpose, pre-medical MRI scanner designed with the goal of demonstrating dental imaging at low field settings. We encode spatial information with two variations of zero-echo time (ZTE) pulse sequences: Pointwise-Encoding Time reduction with Radial Acquisition (PETRA) and a new sequence we have called Double Radial Non-Stop Spin Echo (DRaNSSE), which we find to perform better than the former. For image reconstruction we employ Algebraic Reconstruction Techniques (ART) as well as standard Fourier methods. A noise analysis of the resulting images shows that ART reconstructions exhibit a higher signal to noise ratio with a more homogeneous noise distribution.