Source author record

Indrajit V. Barve

Indrajit V. Barve appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2021arXiv

Solar Radio Spectro-polarimetry (50-500 MHz) : Design and Development of Cross-Polarized Log-Periodic Dipole antenna and configuration of receiver system

A radio spectro-polarimeter was developed at the Gauribidanur radio observatory to study the characteristics of the polarized radio waves that are emitted by the impetuous solar corona in the 50 - 500 MHz frequency range. The instrument has three major components : a Cross-polarized Log-Periodic Dipole Antenna (CLPDA), an analog receiver, and a digital receiver (spectrum analyzer). This article elaborates the design and developmental aspects of the CLPDA, its characteristics and briefs about the configurations of the analog and digital receivers, setting up of the spectro-polarimeter, stage-wise tests performed to characterize it, etc. To demonstrate the instrumental capability, the estimation of the solar coronal magnetic field strength (B {\it Vs} heliocentric height), using the spectral data obtained with it, is exemplified. Throughout the above band, the CLPDA has a gain, return loss and polarization cross-talk of $\approx$ 6.6 dBi, $\lesssim$ -10 dB, and $\lesssim$ -27 dB, respectively. The design constraints, the procedure to tune its impedance and to minimize its dimension, etc. are elaborated. The analog receiver has a noise figure of $\approx 3$ dB and a receiver-noise-temperature ($T_{rcvr}$) of about 290 K. The receiver-flux-density ($S_{rcvr}$) is $\approx 5.3 \times 10^3 $, and $\approx 5.3 \times 10^5$ Jy at 50 and 500 MHz, respectively. The observed spectral data shows a Signal-to-Noise Ratio and Dynamic range of about 30 dB and 40 dB, respectively, at 50 MHz. The average polarization isolation / cross-talk of the CLPD varies from -30 dB to -24 dB over an azimuthal angle of $\pm 45^\circ$ with respect to the reference position angle ($0^\circ$). The average degree of circular polarization (DCP) is $\approx 100\%$ at the reference position and found to decrease gradually and reaches $\approx 80\%$ at an azimuthal angle of $\pm 45^\circ$.

preprint2016arXiv

Design and performance of a low frequency cross-polarized log-periodic dipole antenna

We report the design and performance of a cross-polarized log-periodic dipole (CLPD) antenna for observations of polarized radio emission from the solar corona at low frequencies. The measured isolation between the two mutually orthogonal log periodic dipole antennas was as low as $\approx$ -43 dBm in the 65-95 MHz range. We carried out observations of the solar corona at 80 MHz with the above CLPD and successfully recorded circularly polarized emission.

preprint2016arXiv

In-orbit Performance of UVIT on ASTROSAT

We present the in-orbit performance and the first results from the ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of view of 28 $arcmin$. The FUV and the NUV detectors are operated in the high gain photon counting mode whereas the VIS detector is operated in the low gain integration mode. The FUV and NUV channels have filters and gratings, whereas the VIS channel has filters. The ASTROSAT was launched on 28th September 2015. The performance verification of UVIT was carried out after the opening of the UVIT doors on 30th November 2015, till the end of March 2016 within the allotted time of 50 days for calibration. All the on-board systems were found to be working satisfactorily. During the PV phase, the UVIT observed several calibration sources to characterise the instrument and a few objects to demonstrate the capability of the UVIT. The resolution of the UVIT was found to be about 1.4 - 1.7 $arcsec$ in the FUV and NUV. The sensitivity in various filters were calibrated using standard stars (white dwarfs), to estimate the zero-point magnitudes as well as the flux conversion factor. The gratings were also calibrated to estimate their resolution as well as effective area. The sensitivity of the filters were found to be reduced up to 15\% with respect to the ground calibrations. The sensitivity variation is monitored on a monthly basis. UVIT is all set to roll out science results with its imaging capability with good resolution and large field of view, capability to sample the UV spectral region using different filters and capability to perform variability studies in the UV.

preprint2012arXiv

RRI-GBT Multi-Band Receiver: Motivation, Design & Development

We report the design and development of a self-contained multi-band receiver (MBR) system, intended for use with a single large aperture to facilitate sensitive & high time-resolution observations simultaneously in 10 discrete frequency bands sampling a wide spectral span (100-1500 MHz) in a nearly log-periodic fashion. The development of this system was primarily motivated by need for tomographic studies of pulsar polar emission regions. Although the system design is optimized for the primary goal, it is also suited for several other interesting astronomical investigations. The system consists of a dual-polarization multi-band feed (with discrete responses corresponding to the 10 bands pre-selected as relatively RFI-free), a common wide-band RF front-end, and independent back-end receiver chains for the 10 individual sub-bands. The raw voltage time-sequences corresponding to 16 MHz bandwidth each for the two linear polarization channels and the 10 bands, are recorded at the Nyquist rate simultaneously. We present the preliminary results from the tests and pulsar observations carried out with the Green Bank Telescope using this receiver. The system performance implied by these results, and possible improvements are also briefly discussed.