Source author record

Ian Tosh

Ian Tosh appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

Project overview and update on WEAVE: the next generation wide-field spectroscopy facility for the William Herschel Telescope

We present an overview of and status report on the WEAVE next-generation spectroscopy facility for the William Herschel Telescope (WHT). WEAVE principally targets optical ground-based follow up of upcoming ground-based (LOFAR) and space-based (Gaia) surveys. WEAVE is a multi-object and multi-IFU facility utilizing a new 2-degree prime focus field of view at the WHT, with a buffered pick-and-place positioner system hosting 1000 multi-object (MOS) fibres, 20 integral field units, or a single large IFU for each observation. The fibres are fed to a single spectrograph, with a pair of 8k(spectral) x 6k (spatial) pixel cameras, located within the WHT GHRIL enclosure on the telescope Nasmyth platform, supporting observations at R~5000 over the full 370-1000nm wavelength range in a single exposure, or a high resolution mode with limited coverage in each arm at R~20000. The project is now in the final design and early procurement phase, with commissioning at the telescope expected in 2017.

preprint2010arXiv

Fibre Positioning Revisited: The use an off-the-shelf assembly robot for OPTIMOS-EVE

The OPTIMOS-EVE instrument proposed for the E-ELT aims to use the maximum field of view available to the E-ELT in the limit of natural or ground-layer-corrected seeing for high multiplex fibre-fed multi-object spectroscopy in the visible and near-IR. At the bare nasmyth focus of the telescope, this field corresponds to a focal plane 2.3m in diameter, with a plate-scale of ~3mm/arcsec. The required positioning accuracy that is implied by seeing limited performance at this plate-scale brings the system into the range of performances of commercial off-the-shelf robots that are commonly used in industrial manufacturing processes. The cost-benefits that may be realized through such an approach must be offset against the robot performance, and the ease with which a useful software system can be implemented. We therefore investigate whether the use of such a system is indeed feasible for OPTIMOS-EVE, and the possibilities of extending this approach to other instruments that are currently in the planning stage.