Source author record

I. Percheron

I. Percheron appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Improving the diameters of interferometric calibrators with MATISSE

A good knowledge of the angular diameters of stars used to calibrate the observables in stellar interferometry is fundamental. As the available precision for giant stars is worse than the required per cent level, we aim to improve the knowledge of many diameters using MATISSE (Multiple AperTure mid-Infrared SpectroScopic Experiment) data in its different instrumental configurations. Using the squared visibility MATISSE observable, we compute the angular diameter value, which ensures the best-fitting curves, assuming an intensity distribution of a uniform disc. We take into account that the transfer function varies over the wavelength and is different from one instrumental configuration to another. The uncertainties on the diameters are estimated using the residual bootstrap method. Using the low spectral resolution mode in the L band, we observed a set of 35 potential calibrators selected in the Mid-infrared stellar Diameter and Flux Compilation Catalogue with diameters ranging from about 1 to 3 mas. We reach a precision on the diameter estimates in the range 0.6 per cent to 4.1 per cent. The study of the stability of the transfer function in visibility over two nights makes us confident in our results. In addition, we identify one star, 75 Vir initially present in the calibrator lists, for which our method does not converge, and prove to be a binary star. This leads us to the conclusion that our method is actually necessary to improve the quality of the astrophysical results obtained with MATISSE, and that it can be used as a useful tool for 'bad calibrator' detection.

preprint2022arXiv

MATISSE, the VLTI mid-infrared imaging spectro-interferometer

Context:Optical interferometry is at a key development stage. ESO's VLTI has established a stable, robust infrastructure for long-baseline interferometry for general astronomical observers. The present second-generation instruments offer a wide wavelength coverage and improved performance. Their sensitivity and measurement accuracy lead to data and images of high reliability. Aims:We have developed MATISSE, the Multi AperTure mid-Infrared SpectroScopic Experiment, to access high resolution imaging in a wide spectral domain and explore topics such: stellar activity and mass loss; planet formation and evolution in the gas and dust disks around young stars; accretion processes around super massive black holes in AGN. Methods:The instrument is a spectro-interferometric imager covering three atmospheric bands (L,M,N) from 2.8 to 13.0 mu, combining four optical beams from the VLTI's telscopes. Its concept, related observing procedure, data reduction and calibration approach are the product of 30 years of instrumental research. The instrument utilizes a multi-axial beam combination that delivers spectrally dispersed fringes. The signal provides the following quantities at several spectral resolutions: photometric flux, coherent fluxes, visibilities, closure phases, wavelength differential visibilities and phases, and aperture-synthesis imaging. Results:We provide an overview of the physical principle of the instrument and its functionalities, the characteristics of the delivered signal, a description of the observing modes and of their performance limits. An ensemble of data and reconstructed images are illustrating the first acquired key observations. Conclusion:The instrument has been in operation at Cerro Paranal, ESO, Chile since 2018, and has been open for science use by the international community since April 2019. The first scientific results are being published now.

preprint2020arXiv

The asymmetric inner disk of the Herbig Ae star HD 163296 in the eyes of VLTI/MATISSE: evidence for a vortex?

Context. The inner few au region of planet-forming disks is a complex environment. High angular resolution observations have a key role in understanding the disk structure and the dynamical processes at work. Aims. In this study we aim to characterize the mid-infrared brightness distribution of the inner disk of the young intermediate-mass star HD 163296, from VLTI/MATISSE observations. Methods. We use geometric models to fit the data. Our models include a smoothed ring, a flat disk with inner cavity, and a 2D Gaussian. The models can account for disk inclination and for azimuthal asymmetries as well. We also perform numerical hydro-dynamical simulations of the inner edge of the disk. Results. Our modeling reveals a significant brightness asymmetry in the L-band disk emission. The brightness maximum of the asymmetry is located at the NW part of the disk image, nearly at the position angle of the semimajor axis. The surface brightness ratio in the azimuthal variation is $3.5 \pm 0.2$. Comparing our result on the location of the asymmetry with other interferometric measurements, we confirm that the morphology of the $r<0.3$ au disk region is time-variable. We propose that this asymmetric structure, located in or near the inner rim of the dusty disk, orbits the star. For the physical origin of the asymmetry, we tested a hypothesis where a vortex is created by Rossby wave instability, and we find that a unique large scale vortex may be compatible with our data. The half-light radius of the L-band emitting region is $0.33\pm 0.01$ au, the inclination is ${52^\circ}^{+5^\circ}_{-7^\circ}$, and the position angle is $143^\circ \pm 3^\circ$. Our models predict that a non-negligible fraction of the L-band disk emission originates inside the dust sublimation radius for $μ$m-sized grains. Refractory grains or large ($\gtrsim 10\ μ$m-sized) grains could be the origin for this emission.

preprint2016arXiv

An overview of the mid-infrared spectro-interferometer MATISSE: science, concept, and current status

MATISSE is the second-generation mid-infrared spectrograph and imager for the Very Large Telescope Interferometer (VLTI) at Paranal. This new interferometric instrument will allow significant advances by opening new avenues in various fundamental research fields: studying the planet-forming region of disks around young stellar objects, understanding the surface structures and mass loss phenomena affecting evolved stars, and probing the environments of black holes in active galactic nuclei. As a first breakthrough, MATISSE will enlarge the spectral domain of current optical interferometers by offering the L and M bands in addition to the N band. This will open a wide wavelength domain, ranging from 2.8 to 13 um, exploring angular scales as small as 3 mas (L band) / 10 mas (N band). As a second breakthrough, MATISSE will allow mid-infrared imaging - closure-phase aperture-synthesis imaging - with up to four Unit Telescopes (UT) or Auxiliary Telescopes (AT) of the VLTI. Moreover, MATISSE will offer a spectral resolution range from R ~ 30 to R ~ 5000. Here, we present one of the main science objectives, the study of protoplanetary disks, that has driven the instrument design and motivated several VLTI upgrades (GRA4MAT and NAOMI). We introduce the physical concept of MATISSE including a description of the signal on the detectors and an evaluation of the expected performances. We also discuss the current status of the MATISSE instrument, which is entering its testing phase, and the foreseen schedule for the next two years that will lead to the first light at Paranal.

preprint2012arXiv

Fringe tracking performance monitoring: FINITO at VLTI

Since April 2011, realtime fringe tracking data are recorded simultaneously with data from the VLTI/AMBER interferometric beam combiner. Not only this offers possibilities to post-process AMBER reduced data to obtain more accurate interferometric quantities, it also allows to estimate the performance of the fringe tracking a function of the conditions of seeing, coherence time, flux, etc. First we propose to define fringe tracking performance metrics in the AMBER context, in particular as a function of AMBER's integration time. The main idea is to determine the optimal exposure time for AMBER: short exposures are dominated by readout noise and fringes in long exposures are completely smeared out. Then we present this performance metrics correlated with Paranal local ASM (Ambient Site Monitor) measurements, such as seeing, coherence time or wind speed for example. Finally, we also present some preliminary results of attempts to model and predict fringe tracking performances, using Artificial Neural Networks.

preprint2009arXiv

A List of Bright Interferometric Calibrators measured at the ESO VLTI

In a previous publication (Richichi & Percheron 2005) we described a program of observations of candidate calibrator stars at the ESO Very Large Telescope Interferometer (VLTI), and presented the main results from a statistical point of view. In the present paper, we concentrate on establishing a new homogeneous group of bright interferometric calibrators, based entirely on publicly available K-band VLTI observations carried out with the VINCI instrument up to July 2004. For this, we have defined a number of selection criteria for the quality and volume of the observations, and we have accordingly selected a list of 17 primary and 47 secondary calibrators. We have developed an approach to a robust global fit for the angular diameters using the whole volume of quality-controlled data, largely independent of a priori assumptions. Our results have been compared with direct measurements, and indirect estimates based on spectrophotometric methods, and general agreement is found within the combined uncertainties. The stars in our list cover the range K=-2.9 to +3.0 mag in brightness, and 1.3 to 20.5 milliarcseconds in uniform-disk diameter. The relative accuracy of the angular diameter values is on average 0.4% and 2% for the primary and secondary calibrators respectively. Our calibrators are well suited for interferometric observations in the near-infrared on baselines between ~20m and ~200m, and their accuracy is superior, at least for the primary calibrators, to other similar catalogues. Therefore, the present list of calibrators has the potential to lead to significantly improved interferometric scientific results.