Researcher profile

Hua Ji

Hua Ji contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

A Coarse-to-fine Morphological Approach With Knowledge-based Rules and Self-adapting Correction for Lung Nodules Segmentation

The segmentation module which precisely outlines the nodules is a crucial step in a computer-aided diagnosis(CAD) system. The most challenging part of such a module is how to achieve high accuracy of the segmentation, especially for the juxtapleural, non-solid and small nodules. In this research, we present a coarse-to-fine methodology that greatly improves the thresholding method performance with a novel self-adapting correction algorithm and effectively removes noisy pixels with well-defined knowledge-based principles. Compared with recent strong morphological baselines, our algorithm, by combining dataset features, achieves state-of-the-art performance on both the public LIDC-IDRI dataset (DSC 0.699) and our private LC015 dataset (DSC 0.760) which closely approaches the SOTA deep learning-based models' performances. Furthermore, unlike most available morphological methods that can only segment the isolated and well-circumscribed nodules accurately, the precision of our method is totally independent of the nodule type or diameter, proving its applicability and generality.

preprint2022arXiv

LiDetector: License Incompatibility Detection for Open Source Software

Open-source software (OSS) licenses dictate the conditions which should be followed to reuse, distribute, and modify the software. Apart from widely-used licenses such as the MIT License, developers are also allowed to customize their own licenses (called custom licenses), whose descriptions are more flexible. The presence of such various licenses imposes challenges to understanding licenses and their compatibility. To avoid financial and legal risks, it is essential to ensure license compatibility when integrating third-party packages or reusing code accompanied with licenses. In this work, we propose LiDetector, an effective tool that extracts and interprets OSS licenses (including both official licenses and custom licenses), and detects license incompatibility among these licenses. Specifically, LiDetector introduces a learning-based method to automatically identify meaningful license terms from an arbitrary license and employs Probabilistic Context-Free Grammar (PCFG) to infer rights and obligations for incompatibility detection. Experiments demonstrate that LiDetector outperforms existing methods with 93.28% precision for term identification, and 91.09% accuracy for right and obligation inference, and can effectively detect incompatibility with a 10.06% FP rate and 2.56% FN rate. Furthermore, with LiDetector, our large-scale empirical study on 1,846 projects reveals that 72.91% of the projects are suffering from license incompatibility, including popular ones such as the MIT License and the Apache License. We highlighted lessons learned from the perspectives of different stakeholders and made all related data and the replication package publicly available to facilitate follow-up research.

preprint2022arXiv

MHSnet: Multi-head and Spatial Attention Network with False-Positive Reduction for Pulmonary Nodules Detection

The mortality of lung cancer has ranked high among cancers for many years. Early detection of lung cancer is critical for disease prevention, cure, and mortality rate reduction. However, existing detection methods on pulmonary nodules introduce an excessive number of false positive proposals in order to achieve high sensitivity, which is not practical in clinical situations. In this paper, we propose the multi-head detection and spatial squeeze-and-attention network, MHSnet, to detect pulmonary nodules, in order to aid doctors in the early diagnosis of lung cancers. Specifically, we first introduce multi-head detectors and skip connections to customize for the variety of nodules in sizes, shapes and types and capture multi-scale features. Then, we implement a spatial attention module to enable the network to focus on different regions differently inspired by how experienced clinicians screen CT images, which results in fewer false positive proposals. Lastly, we present a lightweight but effective false positive reduction module with the Linear Regression model to cut down the number of false positive proposals, without any constraints on the front network. Extensive experimental results compared with the state-of-the-art models have shown the superiority of the MHSnet in terms of the average FROC, sensitivity and especially false discovery rate (2.98% and 2.18% improvement in terms of average FROC and sensitivity, 5.62% and 28.33% decrease in terms of false discovery rate and average candidates per scan). The false positive reduction module significantly decreases the average number of candidates generated per scan by 68.11% and the false discovery rate by 13.48%, which is promising to reduce distracted proposals for the downstream tasks based on the detection results.