Source author record

Hua Geng

Hua Geng appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Transient Stability of Low-Inertia Power Systems with Inverter-Based Generation

This study examines the transient stability of low-inertia power systems with inverter-based generation (IBG) and proposes a sufficient stability criterion. In low-inertia grids, transient interactions are induced between the electromagnetic dynamics of the IBG and the electromechanical dynamics of the synchronous generator (SG) under a fault. For this, a hybrid IBG-SG system is established and a delta-power-frequency model is developed. Based on this model, new mechanisms of transient instability different from those of conventional power systems from the energy perspective are discovered. First, two loss-of-synchronization (LOS) types are identified based on the relative power imbalance owing to the mismatch between the inertia of the IBG and SG under a fault. Second, the relative angle and frequency will jump at the moment of a fault, thus affecting the system energy. Third, the cosine damping coefficient induces a positive energy dissipation, thereby contributing to the system stability. A unified criterion for identifying the two LOS types is proposed using the energy function method. This criterion is proved to be a sufficient stability condition for addressing the effects of the jumps and cosine damping coefficient on the system stability. The new mechanisms and effectiveness of the criterion are verified based on simulation results.

preprint2021arXiv

Transient Stability of Hybrid Power Systems Dominated by Different Types of Grid-Forming Devices

This paper investigates the transient stability of power systems co-dominated by different types of grid-forming (GFM) devices. Synchronous generators (SGs and VSGs) and droop-controlled inverters are typical GFM devices in modern power systems. SGs/VSGs are able to provide inertia while droop-controlled inverters are generally inertialess. The transient stability of power systems dominated by homogeneous GFM devices has been extensively studied. Regarding the hybrid system jointly dominated by heterogeneous GFM devices, the transient stability is rarely reported. This paper aims to fill this gap. It is found that the synchronization behavior of the hybrid system can be described by a second-order motion equation, resembling the swing equation of SGs. Moreover, two significant differences from conventional power systems are discovered. The first is that the droop control dramatically enhances the damping effect, greatly affecting the transient stability region. The second is that the frequency state variable exhibits a jump at the moment of fault disturbances, thus impacting the post-fault initial-state location and stability assessment. The underlying mechanism behind the two new characteristics is clarified and the impact on the transient stability performance is analyzed and verified. The findings provide new insights into transient stability of power systems hosting heterogeneous devices.