Source author record

Hermann Brunner

Hermann Brunner appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Establishing the X-ray Source Detection Strategy for eROSITA with Simulations

The eROSITA X-ray telescope on board the Spectrum-Roentgen-Gamma (SRG) satellite has started to detect new X-ray sources over the full sky at an unprecedented rate. Understanding the performance and selection function of the source detection is important for the subsequent scientific analysis of the eROSITA catalogs. Through simulations, we test and optimize the eROSITA source detection procedures, and we characterize the detected catalog quantitatively. Taking the eROSITA Final Equatorial-Depth Survey (eFEDS) as an example, we ran extensive photon-event simulations based on our best knowledge of the instrument characteristics, the background spectrum, and the population of astronomical X-ray sources. We introduce a method of analyzing source detection completeness, purity, and efficiency based on the origin of each photon. According to the source detection efficiency measured in the simulation, we chose a two-pronged strategy to build eROSITA X-ray catalogs, creating a main catalog using only the most sensitive band (0.2-2.3 keV) and an independent hard-band-selected catalog using multiband detection in a range up to 5 keV. Because our mock data are highly representative of the real eFEDS data, we used the mock catalogs to measure the completeness and purity of the eFEDS catalogs as a function of multiple parameters, such as detection likelihood, flux, and luminosity. These measurements provide a basis for choosing the eFEDS catalog selection thresholds. The mock catalogs (available with this paper) can be used to construct the selection function of active galactic nuclei and galaxy clusters. A direct comparison of the output and input mock catalogs also gives rise to a correction curve that converts the raw point-source flux distribution into the intrinsic number counts distribution.

preprint2022arXiv

The eROSITA extragalactic CalPV serendipitous catalog

The eROSITA X-ray telescope on board the Spectrum-Roentgen-Gamma (SRG) observatory performed calibration and performance verification (CalPV) observations between September 2019 and December 2019, ahead of the planned four-year all-sky surveys. Most of them were deep, pointing-mode observations. We present here the X-ray catalog detected from the set of extra-galactic CalPV observations released to the public by the German eROSITA consortium, and the multiband counterparts of these X-ray sources. We developed a source detection method optimized for point-like X-ray sources by including extended X-ray emission in the background measurement. The multiband counterparts were identified using a Bayesian method from the CatWISE catalog. Combining 11 CalPV fields, we present a catalog containing 9515 X-ray sources, whose X-ray fluxes were measured through spectral fitting. CatWISE counterparts are presented for 77% of the sources. Significant variabilities are found in 99 of the sources, which are also presented with this paper. Most of these fields show similar number counts of point sources as typical extragalactic fields, and a few harbor particular stellar populations.

preprint2010arXiv

An X-ray Selected Galaxy Cluster in the Lockman Hole at Redshift 1.753

We have discovered an X-ray selected galaxy cluster with a spectroscopic redshift of 1.753. The redshift is of the brightest cluster galaxy (BCG), which is coincident with the peak of the X-ray surface brightness. We also have concordant photometric redshifts for seven additional candidate cluster members. The X-ray luminosity of the cluster is 3.68 +/- 0.70 x 10^43 erg s^-1 in the 0.1 - 2.4 keV band. The optical/IR properties of the BCG imply its formation redshift was ~5 if its stars formed in a short burst. This result continues the trend from lower redshift in which the observed properties of BCGs are most simply explained by a monolithic collapse at very high redshift instead of the theoretically preferred gradual hierarchical assembly at later times. However the models corresponding to different formation redshifts are more clearly separated as our observation epoch approaches the galaxy formation epoch. Although our infrared photometry is not deep enough to define a red sequence, we do identify a few galaxies at the cluster redshift that have the expected red sequence photometric properties.

preprint2010arXiv

eROSITA on SRG

eROSITA (extended ROentgen Survey with an Imaging Telescope Array) is the core instrument on the Russian Spektrum-Roentgen-Gamma (SRG) mission which is scheduled for launch in late 2012. eROSITA is fully approved and funded by the German Space Agency DLR and the Max-Planck-Society.The design driving science is the detection of 50-100 thousands Clusters of Galaxies up to redshift z~1.3 in order to study the large scale structure in the Universe and test cosmological models, especially Dark Energy. This will be accomplished by an all-sky survey lasting for four years plus a phase of pointed observations. eROSITA consists of seven Wolter-I telescope modules, each equipped with 54 Wolter-I shells having an outer diameter of 360 mm. This would provide and effective area at 1.5 keV of ~1500 cm2 and an on axis PSF HEW of 15" which would provide an effective angular resolution of 25"-30". In the focus of each mirror module, a fast frame-store pn-CCD will provide a field of view of 1deg in diameter for an active FOV of ~0.83 deg2. At the time of writing the instrument development is currently in phase C/D.