Source author record

Helmut Feuchtgruber

Helmut Feuchtgruber appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2023arXiv

First on-sky results of ERIS at VLT

ERIS (Enhanced Resolution Imager and Spectrograph) is a new adaptive optics instrument installed at the Cassegrain focus of the VLT-UT4 telescope at the Paranal Observatory in Chile. ERIS consists of two near-infrared instruments: SPIFFIER, an integral field unit (IFU) spectrograph covering J to K bands, and NIX, an imager covering J to M bands. ERIS has an adaptive optics system able to work with both LGS and NGS. The Assembly Integration Verification (AIV) phase of ERIS at the Paranal Observatory was carried out starting in December 2021, followed by several commissioning runs in 2022. This contribution will describe the first preliminary results of the on-sky performance of ERIS during its commissioning and the future perspectives based on the preliminary scientific results.

preprint2014arXiv

Herschel/PACS spectroscopy of trace gases of the stratosphere of Titan

Aims: We investigate the composition of Titan's stratosphere from new medium-resolution far-infrared observations performed with the full range of Herschel's Photodetector Array Camera and Spectrometer (PACS) (51-220 $μ$m at a resolution $λ$/$Δλ$ ranging from 950 to 5500 depending on wavelength and grating order). Methods: Using PACS, we obtained the spectral emission of several features of the Titan's stratosphere. We used a line-by-line radiative transfer code and the least-squares fitting technique to infer the abundances of the trace constituents. Results: Numerous spectral features attributable to CH$_4$, CO, HCN, and H$_2$O are present. From the flux density spectrum measured and by a detailed comparison with synthetic spectra, we constrain the stratospheric abundance of CH4, which is assumed to be constant with altitude, to be 1.29 $\pm$ 0.03%. Similarly, we constrain the abundance of CO to be 50 $\pm$ 2 ppm, and the HCN vertical distribution consistent with an increase from 40 ppb at $\sim$100 km to 4 ppm at $\sim$200 km, which is an altitude region where the HCN signatures are sensitive. Measurements of three H$_2$O rotational lines confirm the H$_2$O distribution profile recently obtained with Herschel. Furthermore, we determine the isotopic ratios $^{12}$C/$^{13}$C in CO and HCN to be 124 $\pm$ 58, and 66 $\pm$ 35, respectively. Comparisons between our results and the values derived with other instruments show that our results are consistent with the vertical distributions and isotopic ratios in previous studies, except for the HCN distribution obtained with Cassini/CIRS, which does not agree with the PACS lines at the 1-sigma confidence interval.

preprint2014arXiv

Operations and Performance of the PACS Instrument 3He Sorption Cooler on board of the Herschel Space Observatory

A 3He sorption cooler produced the operational temperature of 285mK for the bolometer arrays of the Photodetector Array Camera and Spectrometer (PACS) instrument of the Herschel Space Observatory. This cooler provided a stable hold time between 60 and 73h, depending on the operational conditions of the instrument. The respective hold time could be determined by a simple functional relation established early on in the mission and reliably applied by the scientific mission planning for the entire mission. After exhaustion of the liquid 3He due to the heat input by the detector arrays, the cooler was recycled for the next operational period following a well established automatic procedure. We give an overview of the cooler operations and performance over the entire mission and distinguishing in-between the start conditions for the cooler recycling and the two main modes of PACS photometer operations. As a spin-off, the cooler recycling temperature effects on the Herschel cryostat 4He bath were utilized as an alternative method to dedicated Direct Liquid Helium Content Measurements in determining the lifetime of the liquid Helium coolant.

preprint2014arXiv

The Pointing System of the Herschel Space Observatory. Description, Calibration, Performance and Improvements

We present the activities carried out to calibrate and characterise the performance of the elements of attitude control and measurement on board the Herschel spacecraft. The main calibration parameters and the evolution of the indicators of the pointing performance are described, from the initial values derived from the observations carried out in the performance verification phase to those attained in the last year and half of mission, an absolute pointing error around or even below 1 arcsec, a spatial relative pointing error of some 1 arcsec and a pointing stability below 0.2 arsec. The actions carried out at the ground segment to improve the spacecraft pointing measurements are outlined. On-going and future developments towards a final refinement of the Herschel astrometry are also summarised. A brief description of the different components of the attitude control and measurement system (both in the space and in the ground segments) is also given for reference. We stress the importance of the cooperation between the different actors (scientists, flight dynamics and systems engineers, attitude control and measurement hardware designers, star-tracker manufacturers, etc.) to attain the final level of performance.

preprint2012arXiv

Impacts of The Radiation Environment At L2 On Bolometers Onboard The Herschel Space Observatory

We present the effects of cosmic rays on the detectors onboard the Herschel satellite. We describe in particular the glitches observed on the two types of cryogenic far- infrared bolometer inside the two instruments PACS and SPIRE. The glitch rates are also reported since the launch together with the SREM radiation monitors aboard Herschel and Planck spacecrafts. Both have been injected around the Lagrangian point L2 on May 2009. This allows probing the radiation environment around this orbit. The impacts on the observation are finally summarized.