Researcher profile

Hamzeh Davarikia

Hamzeh Davarikia contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

Power Systems Transient Stability Indices: Hierarchical Clustering Based Detection of Coherent Groups Of Generators

Coherent groups of generators, i.e., machines with perfectly correlated rotor angles, play an important role in power system stability analysis. This paper introduces a real-time methodology based on hierarchical clustering techniques for discovering the degree of coherency among generators using the synchronization coefficient and the correlation coefficient of the generators' rotor angle as the coherency index. Furthermore, the Power Transient Stability Indices (PTSI) were employed to examine the versatile response of the power system. The method uses power systems transients Stability indices, i.e., power Connectivity Factor (CF) index which presents coherently strong generators within the groups, the power Separation Factor (SF) index which unveils to the extent that the generators in different groups tend to swing against the other groups in the event of a disturbance, and the overall system separation index which demonstrates the overall system separation status (CF/SF). The approach is assessed on an IEEE-39 test system with a fully dynamic model. The simulation results presented in this paper demonstrate the efficiency of the proposed approach.

preprint2020arXiv

Coherency Detection and Network Partitioning based on Hierarchical DBSCAN

After a sudden disturbance, the energy balance of generators is disturbed, and the power outputs of synchronous generators vary as their rotor angles shift from their equilibrium points. This trend essentially presents the versatile response of each machine to the disturbance. Because of this change, the phase angle of the bus also differs. Hence, the versatile response of each machine can be assessed by the phase angles change at the buses close to the synchronous generator. This paper introduces a new methodology for discovering the degree of coherency among buses using the correlation index of the voltage angle between each pair of buses and use the Hierarchical Density-Based Spatial Clustering of Applications with Noise (HDBSCAN) to partition the network into islands. The proposed approach also provides the network integrity indices (connectivity, splitting, and separation) for studying the dynamic nature of the power network system. The approach is assessed on an IEEE 39 test system with a fully dynamic model. The simulation results presented in this paper demonstrate the efficiency of the proposed approach.

preprint2020arXiv

Constraint Clustering Based Islanding Scheme For Power Networks

Controlled islanding, which splits the whole power system into islands, is an effective strategy against rolling blackout during severe disturbances. Finding the islanding solutions in a real-time manner is complicated because of the combinatorial explosion of the solution space occurs for a large power network. In this work, a computationally efficient controlled islanding algorithm is proposed that uses constrained spectral clustering while addressing the generator coherency problem. The objective function used in this controlled islanding algorithm is the minimal power-flow disruption. The sole constraint applied to this solution is related to generator coherency. An undirected edge-weighted graph is created based on absolute values of apparent power flow and constraints related to transmission line availability and coherent generator groups are included by altering the edge weights of the graph and using a subspace projection. Spectral clustering is then applied to the constrained solution subspace to find the islanding solution. The methodology is tested on an IEEE-39 test system with a fully dynamic model. Simulation results demonstrate the efficacy of our approach.

preprint2020arXiv

Routing of Electric Vehicles in a Stochastic Network with Non-recurrent Incidents

An approach for mapping an electric vehicle EV driver s travel time constraints and risk taking behavior to real time routing in a probabilistic time-dependent or stochastic network is proposed in this paper. The proposed approach is based on a heuristic algorithm that finds the shortest path according to the driver s preferences. Accounting for en route delays and alternate routes, the EV routing problem in stochastic networks is shown to exhibit other than the First In First Out FIFO property i.e. the traveling time for those who depart earlier may not sooner of those who depart later or wait en route in the charging stations. The proposed approach provides EV drivers the option to manage their trip and reach the destination on time, while by taking advantage of the non FIFO characteristics of the traffic network, charge their cars en route. The proposed routing algorithm is tested on a given stochastic transportation network. The best routes based on the driver s preferences are identified while accounting for the best-planned delays at the charging stations or en-route.