Researcher profile

H. Tom Soh

H. Tom Soh contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Design and Analysis of a Sample-and-Hold CMOS Electrochemical Sensor for Aptamer-based Therapeutic Drug Monitoring

In this paper, we present the design and the analysis of an electrochemical circuit for measuring the concentrations of therapeutic drugs using structure-switching aptamers. Aptamers are single-stranded nucleic acids, whose sequence is selected to exhibit high affinity and specificity toward a molecular target, and change its conformation upon binding. This property, when coupled with a redox reporter and electrochemical detection, enables reagent-free biosensing with a sub-minute temporal resolution for in vivo therapeutic drug monitoring. Specifically, we design a chronoamperometry-based electrochemical circuit that measures the direct changes in the electron transfer (ET) kinetics of a methylene blue reporter conjugated at the distal-end of the aptamer. To overcome the high-frequency noise amplification issue when interfacing with a large-size (> 0.25 mm2) implantable electrode, we present a sample-and-hold (S/H) circuit technique in which the desired electrode potentials are held onto noiseless capacitors during the recording of the redox currents. This allows disconnecting the feedback amplifiers to avoid its noise injection while reducing the total power consumption. A prototype circuit implemented in 65-nm CMOS demonstrates a cell-capacitance-insensitive input-referred noise (IRN) current of 15.2 pArms at a 2.5-kHz filtering bandwidth. Tested in human whole blood samples, changes in the ET kinetics from the redox-labeled aminoglycoside aptamers at different kanamycin concentrations are measured from the recorded current waveforms. By employing principal component analysis (PCA) to compensate for the sampling errors, a detection limit (SNR = 1) of 3.1 uM under 1-sec acquisition is achieved at 0.22-mW power consumption.

preprint2020arXiv

Going Beyond the Debye Length: Overcoming Charge Screening Limitations in Next-Generation Bioelectronic Sensors

Electronic biosensors are a natural fit for field-deployable diagnostic devices, because they can be miniaturized, mass produced, and integrated with circuitry. Unfortunately, progress in the development of such platforms has been hindered by the fact that mobile ions present in biological samples screen charges from the target molecule, greatly reducing sensor sensitivity. Under physiological conditions, the thickness of the resulting electric double layer is less than 1 nm, and it has generally been assumed that electronic detection beyond this distance is virtually impossible. However, a few recently-described sensor design strategies seem to defy this conventional wisdom, exploiting the physics of electrical double layers in ways that traditional models do not capture. In the first strategy, charge screening is decreased by constraining the space in which double layers can form. The second strategy uses external stimuli to prevent double layers from reaching equilibrium, thereby effectively reducing charge screening. The goal of this article is to describe these relatively new concepts, and to offer theoretical insights into mechanisms that may enable electronic biosensing beyond the double-layer. If these concepts can be further developed and translated into practical electronic biosensors, we foresee exciting opportunities for the next generation of diagnostic technologies.